Search icon

HANNAH CONSTRUCTION CORPORATION OF TAMPA BAY - Florida Company Profile

Company Details

Entity Name: HANNAH CONSTRUCTION CORPORATION OF TAMPA BAY
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

HANNAH CONSTRUCTION CORPORATION OF TAMPA BAY is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 15 May 2001 (24 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 23 Feb 2011 (14 years ago)
Document Number: P01000050832
FEI/EIN Number 593714397

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 5927 George Road, Tampa, FL, 33634, US
Mail Address: 5927 George Road, TAMPA, FL, 33634, US
ZIP code: 33634
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
BOCIEK ANTON T Officer 5927 George Road, Tampa, FL, 33634
BOCIEK ANTON Agent 5927 George Road, Tampa, FL, 33634

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2024-04-24 5927 George Road, Tampa, FL 33634 -
REGISTERED AGENT ADDRESS CHANGED 2024-04-24 5927 George Road, Tampa, FL 33634 -
CHANGE OF MAILING ADDRESS 2022-04-30 5927 George Road, Tampa, FL 33634 -
REINSTATEMENT 2011-02-23 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2010-09-24 - -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J13000148750 LAPSED 1000000442892 HILLSBOROU 2013-01-07 2023-01-16 $ 1,541.60 STATE OF FLORIDA, DEPARTMENT OF REVENUE, TAMPA SERVICE CENTER, 6302 E DR MARTIN LUTHER KING JR BLVD S, TAMPA FL336191166
J07000373863 LAPSED 06-10613SC-044 PINELLAS COUNTY COURT 2007-03-16 2012-11-16 $4,167.23 SACINOS FINE DRYCLEANING AND RESTORATION LLC, 3430 FAIRFIELD AVE. SOUTH, ST. PETERSBURG, FL 33711
J05900002148 LAPSED 04-25387-K 13TH JUD CIR HILLSBOROUGH CO 2005-01-24 2010-01-31 $2955.76 SONLIGHT CARPETS, INC., 6023 W. LINEBAUGH AVENUE, TAMPA, FL 33625

Documents

Name Date
ANNUAL REPORT 2024-04-24
ANNUAL REPORT 2023-04-24
ANNUAL REPORT 2022-04-30
ANNUAL REPORT 2021-04-29
ANNUAL REPORT 2020-03-26
ANNUAL REPORT 2019-04-28
ANNUAL REPORT 2018-01-22
ANNUAL REPORT 2017-05-01
ANNUAL REPORT 2016-04-30
ANNUAL REPORT 2015-04-19

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
336212386 0420600 2012-09-07 410 SOUTH DALE MABRY HWY., TAMPA, FL, 33609
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-09-07
Emphasis L: EISAOF, L: FALL
Case Closed 2016-11-16

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2012-09-20
Abatement Due Date 2012-09-24
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2012-11-01
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a. Roof - fall protection was not used on a 3:12 pitched roof during roof coating operations and exposed employee to a 12' fall hazard. Violation observed on or about 9/7/12.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2012-09-20
Abatement Due Date 2012-09-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-01
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a. Roof - employer did not train to recognize fall hazards during roof coating operations when there was a 12' fall hazard. Violation observed on or about 9/7/12.
Citation ID 02001
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2012-09-20
Abatement Due Date 2012-09-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-01
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. Roof - employer did not have a written hazard communication program when material such as, but not limited to Lanco White Seal Roof Coating was used during roof coating operations. Violation observed on or about 9/7/12.
Citation ID 02002
Citaton Type Other
Standard Cited 19101200 G01
Issuance Date 2012-09-20
Abatement Due Date 2012-09-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-01
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use: a. Roof - employer did not have material safety data sheet when material such as, but not limited to Lanco White Seal Roof Coating was used during roof coating operations. Violation observed on or about 9/7/12.
Citation ID 02003
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2012-09-20
Abatement Due Date 2012-09-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-01
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): The employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees had not previously been trained about was introduced into their work area: a. Roof - employer did not have hazard communication training when material such as, but not limited to Lanco White Seal Roof Coating was used during roof coating operations. Violation observed on or about 9/7/12.