345018279
|
0419700
|
2020-11-10
|
219 SOUTH ATLANTIC BOULEVARD, DAYTONA BEACH, FL, 32115
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-11-10
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2022-04-19
|
Related Activity
Type |
Inspection |
Activity Nr |
1501826 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260501 B01 |
Issuance Date |
2021-02-24 |
Current Penalty |
1194.0 |
Initial Penalty |
1990.0 |
Final Order |
2022-04-12 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1):Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On November 10, 2020, on the 1st level deck, the employees of the subcontractor performing masonry work were not protected from an 8 and a 1/2 feet fall hazard by the use of a fall protection system. |
|
|
337521819
|
0419700
|
2012-11-14
|
2480 OCEAN SHORE BLVD., ORMOND BEACH, FL, 32173
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-11-14
|
Emphasis |
L: EISAOF, L: EISAX, P: FALL, L: FALL
|
Case Closed |
2013-11-27
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2012-12-03 |
Current Penalty |
1224.0 |
Initial Penalty |
2040.0 |
Final Order |
2012-12-12 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about November 14, 2012, below the east side balcony, an employee was working underneath the edge of a balcony that was under repair by other employees without the use of a hard hat. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2012-12-03 |
Current Penalty |
1224.0 |
Initial Penalty |
2040.0 |
Final Order |
2012-12-12 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about November 14, 2012 on the east side balcony, an employee working near the edge of the balcony was not protected from a 9 feet 6 inches fall hazard by the use of a fall protection system. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2012-12-03 |
Current Penalty |
1224.0 |
Initial Penalty |
2040.0 |
Final Order |
2012-12-12 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a. On or about November 14, 2012, on the east side balcony, employees were using ladders to access the balcony that did not extend 3 feet above the upper landing surface. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19261053 B05 I |
Issuance Date |
2012-12-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-12-12 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: a. On or about November 14, 2012, on the east side balcony, employees were using ladders to access the balcony that were not used at the proper angle. |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19261053 B16 |
Issuance Date |
2012-12-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-12-12 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: a. On or about November 14, 2012, on the east side balcony, an employee was using a ladder to access the balcony that had the extension piece of the ladder broken off. |
|
|
315478768
|
0419700
|
2011-07-26
|
80 STARLIGHT DRIVE, ORMOND BEACH, FL, 32171
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2011-07-26
|
Emphasis |
S: FALL FROM HEIGHT, S: RESIDENTIAL CONSTR, L: FALL
|
Case Closed |
2011-10-11
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2011-08-16 |
Abatement Due Date |
2011-08-19 |
Current Penalty |
3773.0 |
Initial Penalty |
5390.0 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
10 |
|
|
313882094
|
0419700
|
2011-02-28
|
118 SOUTH HALIFAX, DAYTONA BEACH, FL, 32118
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2011-02-28
|
Emphasis |
N: TRENCH, S: COMMERCIAL CONSTR, S: TRENCHING
|
Case Closed |
2011-04-08
|
Related Activity
Type |
Complaint |
Activity Nr |
208228577 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2011-03-23 |
Abatement Due Date |
2011-03-28 |
Current Penalty |
1666.0 |
Initial Penalty |
2380.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260651 C02 |
Issuance Date |
2011-03-23 |
Abatement Due Date |
2011-03-28 |
Current Penalty |
1666.0 |
Initial Penalty |
2380.0 |
Nr Instances |
3 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
05 |
|
|
310027297
|
0419700
|
2006-08-16
|
2043 SOUTH ATLANTIC AVE., DAYTONA BEACH SHORES, FL, 32118
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2006-08-17
|
Emphasis |
L: FALL
|
Case Closed |
2006-09-26
|
Related Activity
Type |
Complaint |
Activity Nr |
206025769 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100178 L01 II |
Issuance Date |
2006-08-24 |
Abatement Due Date |
2006-09-26 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
|