Search icon

BROTHER'S PLUMBING, INC. - Florida Company Profile

Company Details

Entity Name: BROTHER'S PLUMBING, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

BROTHER'S PLUMBING, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 07 Feb 2001 (24 years ago)
Document Number: P01000014477
FEI/EIN Number 593705515

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 617 PINE STREET, AUBURNDALE, FL, 33823
Mail Address: 617 PINE STREET, AUBURNDALE, FL, 33823
ZIP code: 33823
County: Polk
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ARCINIEGA ENRIQUE President 31 ALABAMA LANE, AUBURNDALE, FL, 33823
ARCINIEGA ENRIQUE Agent 31 ALABAMA LANE, AUBURNDALE, FL, 33823

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2004-04-29 617 PINE STREET, AUBURNDALE, FL 33823 -
CHANGE OF MAILING ADDRESS 2004-04-29 617 PINE STREET, AUBURNDALE, FL 33823 -

Documents

Name Date
ANNUAL REPORT 2024-04-30
ANNUAL REPORT 2023-04-29
ANNUAL REPORT 2022-05-16
ANNUAL REPORT 2021-04-30
ANNUAL REPORT 2020-06-29
ANNUAL REPORT 2019-04-30
ANNUAL REPORT 2018-04-26
ANNUAL REPORT 2017-05-03
ANNUAL REPORT 2016-04-07
ANNUAL REPORT 2015-04-29

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
337971220 0419700 2012-12-20 3209 SOUTH ATLANTIC, DAYTONA BEACH SHORES, FL, 32116
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2012-12-20
Emphasis L: FALL, P: FALL
Case Closed 2016-08-25

Related Activity

Type Inspection
Activity Nr 797301
Safety Yes
Type Inspection
Activity Nr 797163
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2013-01-02
Abatement Due Date 2013-01-29
Current Penalty 1700.0
Initial Penalty 1700.0
Final Order 2013-01-25
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about December 20, 2012, on the north side of the 1st, 2nd, 3rd, and 4th floors, employees were using stairs near an unprotected edge and were not protected from a 32 feet fall hazard, by the use of a fall protection system.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B04 I
Issuance Date 2013-01-02
Abatement Due Date 2013-01-29
Current Penalty 1360.0
Initial Penalty 1360.0
Final Order 2013-01-25
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes: a. On or about December 20, 2012, on the north side of the 3rd floor, employees were working near floor holes that were not covered, exposing themselves to a trip hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261052 C01
Issuance Date 2013-01-02
Abatement Due Date 2013-01-29
Current Penalty 1700.0
Initial Penalty 1700.0
Final Order 2013-01-25
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge: a. On or about December 20, 2012, on the north side, the stairs leading from the 1st to the 2nd floor did not have a stair rail along an unprotected side.