Search icon

B & L SYSTEMS INC. - Florida Company Profile

Company Details

Entity Name: B & L SYSTEMS INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

B & L SYSTEMS INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 25 Jan 2001 (24 years ago)
Date of dissolution: 04 Oct 2002 (23 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 04 Oct 2002 (23 years ago)
Document Number: P01000009641
Address: 1040 WEST BEL AIRE DR., PEMBROKE PINES, FL, 33027
Mail Address: 1040 WEST BEL AIRE DR., PEMBROKE PINES, FL, 33027
ZIP code: 33027
County: Broward
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
BARDINO DEAN E President 1040 WEST BEL AIRE DR., PEMBROKE PINES, FL, 33027
BARDINO DEAN E Treasurer 1040 WEST BEL AIRE DR., PEMBROKE PINES, FL, 33027
LARIVIERE ALFRED J Vice President 1040 WEST BEL AIRE DR., PEMBROKE PINES, FL, 33027
LARIVIERE ALFRED J Director 1040 WEST BEL AIRE DR., PEMBROKE PINES, FL, 33027
BARDINO DEAN Agent 1040 WEST BEL AIRE DR., PEMBROKE PINES, FL, 33027
BARDINO DEAN E Director 1040 WEST BEL AIRE DR., PEMBROKE PINES, FL, 33027
LARIVIERE ALFRED J Secretary 1040 WEST BEL AIRE DR., PEMBROKE PINES, FL, 33027

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2002-10-04 - -

Documents

Name Date
Domestic Profit 2001-01-25

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340879956 0420600 2015-08-27 7205 114TH AVE NORTH, LARGO, FL, 33773
Inspection Type FollowUp
Scope NoInspection
Safety/Health Safety
Close Conference 2015-08-27
Emphasis N: SSTARG14
Case Closed 2015-08-28

Related Activity

Type Inspection
Activity Nr 967729
Safety Yes
339677296 0420600 2014-04-15 7205 114TH AVE NORTH, LARGO, FL, 33773
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-04-15
Emphasis N: SSTARG14, N: SILICA, L: FORKLIFT, P: SSTARG14
Case Closed 2016-07-13

Related Activity

Type Inspection
Activity Nr 1087995
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100022 A01
Issuance Date 2014-04-30
Abatement Due Date 2014-05-12
Current Penalty 1050.0
Initial Penalty 2100.0
Final Order 2014-05-16
Nr Instances 1
Nr Exposed 20
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. a. In the metal fabrication shop, employees were exposed to trip hazards, in that, flexible electrical cords were strewn across walkways and work areas were not kept in a clean, orderly manner, on or about 04/15/2014.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2014-04-30
Abatement Due Date 2014-06-17
Current Penalty 2450.0
Initial Penalty 4900.0
Final Order 2014-05-16
Nr Instances 3
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. In the metal fabrication shop, while using the Central Machinery drill press SN #0819050193 employees were exposed to an amputation hazard, in that, there was no guard in place, on or about 04/15/2014. b. In the metal fabrication shop, while using the Wilton drill press SN # 2530 employees were exposed to an amputation hazard, in that, there was no guard in place, on or about 04/15/2014. c. In the metal fabrication shop, while using the Lown B600 bender employees were exposed to an amputation hazard, in that, there was no guard in place, on or about 04/15/2014.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100215 A04
Issuance Date 2014-04-30
Abatement Due Date 2014-05-12
Current Penalty 2450.0
Initial Penalty 4900.0
Final Order 2014-05-16
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a. In the metal fabrication shop, employees were exposed to an amputation hazard, in that, no work rest present on the 6 inch abrasive wheel grinder 1 SN #964603 used to knock burs off finished parts, and sharpen tools, on or about 04/15/2014.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100252 A02 XIV A
Issuance Date 2014-04-30
Abatement Due Date 2014-07-09
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2014-05-16
Nr Instances 1
Nr Exposed 20
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.252(a)(2)(xiv)(A): The employer did not ensure that the supervisor was responsible for the safe handling of the cutting or welding equipment and the safe use of the cutting or welding process: a. In the metal fabrication shop, employees were exposed to trip hazards, in that, the power cords to welding and cutting equipment were not kept in proximity to the work area they were strewn across walk ways, and welding equipment was not kept in safe operating condition, on or about 04/15/2014
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100252 B01 II
Issuance Date 2014-04-30
Abatement Due Date 2014-05-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-16
Nr Instances 3
Nr Exposed 20
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.252(b)(1)(ii): Welders did not place welding cable and other equipment so that it was clear of passageways, ladders, and stairways: a. In the metal fabrication shop, employees were exposed to trip hazards, in that, the power cords to welding and cutting equipment were not kept in proximity to the work area. They were strewn across walk ways, on or about 04/15/2014.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100253 E03 II C 3
Issuance Date 2014-04-30
Abatement Due Date 2014-05-19
Current Penalty 2450.0
Initial Penalty 4900.0
Final Order 2014-05-16
Nr Instances 5
Nr Exposed 10
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.253(e)(3)(ii)(C)(3): Flashback protection was not provided by an approved device that would prevent flame from passing into the fuel gas system: a. In the metal fabrication shop, employees were exposed to a explosion hazard, in that, there were no flashback arrestors on the acetylene torch rigs while welding or cutting steel, on or about 04/15/2014.
Citation ID 02001
Citaton Type Other
Standard Cited 19100305 A01 I
Issuance Date 2014-04-30
Abatement Due Date 2014-05-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-16
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(a)(1)(i): Metal raceways, cable armor, and other metal enclosures for conductors were not metallically joined together into a continuous electric conductor: a. At the establishment, employees were exposed to an electrocution hazard, in that, the face plate on the outlet beside the warehouse door was pulled off leaving live wires exposed, on or about 04/15/2014.

Date of last update: 01 Apr 2025