Search icon

MADICO, INC. - Florida Company Profile

Company Details

Entity Name: MADICO, INC.
Jurisdiction: FLORIDA
Filing Type: Foreign Profit
Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 11 Jan 1984 (41 years ago)
Last Event: CORPORATE MERGER
Event Date Filed: 18 Dec 2012 (12 years ago)
Document Number: P00552
FEI/EIN Number 042807288

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 9251 Belcher Road N., Pinellas Park, FL, 33782, US
Mail Address: 9251 Belcher Road N., Pinellas Park, FL, 33782, US
ZIP code: 33782
County: Pinellas
Place of Formation: MASSACHUSETTS

form 5500

Plan Name Plan Year EIN/PN Received Sponsor Total number of participants
EMPLOYEES' SAVINGS PLAN OF MADICO, INC. 2018 042807288 2019-10-14 MADICO, INC. 219
File View Page
Three-digit plan number (PN) 003
Effective date of plan 1984-01-01
Business code 332810
Sponsor’s telephone number 7819357850
Plan sponsor’s mailing address 9251 BELCHER ROAD N, PINELLAS PARK, FL, 33782
Plan sponsor’s address 9251 BELCHER ROAD N, PINELLAS PARK, FL, 33782

Number of participants as of the end of the plan year

Active participants 187
Retired or separated participants receiving benefits 0
Other retired or separated participants entitled to future benefits 59
Deceased participants whose beneficiaries are receiving or are entitled to receive benefits 0
Number of participants with account balances as of the end of the plan year 241
Number of participants that terminated employment during the plan year with accrued benefits that were less than 100% vested 0

Signature of

Role Plan administrator
Date 2019-10-14
Name of individual signing CHRIS LAYNE
Valid signature Filed with authorized/valid electronic signature

Key Officers & Management

Name Role Address
Storms John President 9251 Belcher Road N., Pinellas Park, FL, 33782
Plummer Jeffrey Vice President 5939 Bayview Circle Court, South Gulfport, FL, 33707
Killgo Aya Director 9251 Belcher Road N., Pinellas Park, FL, 33782
Yamaoka Mika Director 9251 Belcher Road N., Pinellas Park, FL, 33782
Sakurai Taiji Director 9251 Belcher Rd N, Pinellas Park, FL, 33782
Node Kazuyoshi Director 9251 Belcher Road N., Pinellas Park, FL, 33782
CT CORPORATION SYSTEM Agent 1200 S. PINE ISLAND ROAD, PLANTATION, FL, 33324

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G13000009314 MADICO WINDOW FILMS EXPIRED 2013-01-27 2018-12-31 - 2630 FAIRFIELD AVENUE S., ST. PETERSBURG, FL, 33712
G13000009315 MADICO WINDOW FILMS, INC. EXPIRED 2013-01-27 2018-12-31 - 2630 FAIRFIELD AVENUE S., ST. PETERSBURG, FL, 33712

Events

Event Type Filed Date Value Description
CHANGE OF MAILING ADDRESS 2019-04-18 9251 Belcher Road N., Pinellas Park, FL 33782 -
CHANGE OF PRINCIPAL ADDRESS 2019-04-18 9251 Belcher Road N., Pinellas Park, FL 33782 -
MERGER 2012-12-18 - CORPORATION WAS A MERGER RESULT. TOTAL NUMBER OF QUALIFIED CORPORATION(S) INVOLVED WAS 1. MERGER NUMBER 100000127671
REINSTATEMENT 2004-10-22 - -
REVOKED FOR ANNUAL REPORT 2004-10-01 - -
REINSTATEMENT 2002-11-04 - -
REVOKED FOR ANNUAL REPORT 2002-10-04 - -
REINSTATEMENT 1998-05-22 - -
REVOKED FOR ANNUAL REPORT 1997-09-26 - -
REGISTERED AGENT NAME CHANGED 1992-03-17 CT CORPORATION SYSTEM -

Documents

Name Date
ANNUAL REPORT 2024-04-11
ANNUAL REPORT 2023-04-24
ANNUAL REPORT 2022-06-24
ANNUAL REPORT 2021-04-02
ANNUAL REPORT 2020-05-06
ANNUAL REPORT 2019-04-18
ANNUAL REPORT 2018-05-23
AMENDED ANNUAL REPORT 2017-04-25
ANNUAL REPORT 2017-02-09
ANNUAL REPORT 2016-03-09

USAspending Awards. Contracts

Contract Type Award or IDV Flag PIID Start Date Current End Date Potential End Date
- IDV SFBOAD99D0011 2008-01-05 - -
Unique Award Key CONT_IDV_SFBOAD99D0011_1900
Awarding Agency Department of State
Link View Page

Description

NAICS Code 325211: PLASTICS MATERIAL AND RESIN MANUFACTURING
Product and Service Codes 9330: PLASTICS FABRICATED MATERIALS

Recipient Details

Recipient MADICO INC
UEI DGL4BE6Y89V5
Legacy DUNS 029512717
Recipient Address 4801 S UNIVERSITY DR, FORT LAUDERDALE, 333283839, UNITED STATES

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347873119 0420600 2024-11-12 9251 BELCHER ROAD NORTH, PINELLAS PARK, FL, 33782
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2024-11-12

Related Activity

Type Complaint
Activity Nr 2228472
Safety Yes
Health Yes
345578751 0420600 2021-10-13 9251 BELCHER RD. N., PINELLAS PARK, FL, 33782
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2021-10-13
Emphasis N: AMPUTATE
Case Closed 2022-03-01

Related Activity

Type Complaint
Activity Nr 1819120
Safety Yes
344115829 0420600 2019-06-26 2630 FAIRFIELD AVE SOUTH, SAINT PETERSBURG, FL, 33712
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2019-11-21
Emphasis N: AMPUTATE
Case Closed 2019-12-20

Related Activity

Type Referral
Activity Nr 1467797
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100147 C04 II A
Issuance Date 2019-11-25
Current Penalty 11934.0
Initial Penalty 11934.0
Final Order 2019-12-18
Nr Instances 1
Nr Exposed 15
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(ii)(A): The energy control procedures did not contain a specific statement on the intended use of the procedure: a. On or about June 17, 2019, at the jobsite on coating line two, the Lockout / Tagout program provided to employees operating the Nordson Extrusion Dies Industries (EDI) Ultracoat II Slot Die and the TEKNEK XWCH3 Wide Web Cleaner did not provide the employees a step-by-step procedure or direction on when a LOTO device is required, the purpose of the steps being performed, or how the procedure is protecting employees.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100147 C06 I A
Issuance Date 2019-11-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-12-18
Nr Instances 1
Nr Exposed 15
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(i)(A): The periodic inspection of the energy control procedure was not performed by an authorized employee other than the one utilizing the energy control procedure being inspected: a. On or about June 26, 2019, the periodic inspection of the Lockout / Tagout program for the machinery on coating line two was conducted by employees who routinely work on coating line two and or whom performed routine maintenance on the machinery.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100147 C06 II
Issuance Date 2019-11-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-12-18
Nr Instances 1
Nr Exposed 15
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection: a. On or about June 26, 2019, the periodic inspection of the Lockout / Tagout program for the machinery on coating line dated 10/14/18 has the 001-902 written down for the LOTO number on the Periodic Inspection form and there are three names listed in the space for the Inspector. b. On or about June 26, 2019, the periodic inspection of the LOTO program for the machinery on coating line dated 12/21/17 does not have the equipment name and or Lockout / Tagout number listed on the Periodic Inspection forms.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100147 C07 I
Issuance Date 2019-11-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-12-18
Nr Instances 1
Nr Exposed 15
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a. On or about June 26, 2019, employees working on coating line two were not provided specific Lockout / Tagout (LOTO) training as to the location of power sources, type of LOTO devices required for machinery being serviced and or cleaned and methods of verifying the stored energy has been released, thus exposing employees to severe lacerations and amputations hazards.
Citation ID 01001E
Citaton Type Serious
Standard Cited 19100147 C06 I D
Issuance Date 2019-11-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-12-18
Nr Instances 1
Nr Exposed 15
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(i)(D): Where tagout was used for energy control, the periodic inspection did not include a review between the inspector and each authorized and affected employee of the employee's responsibilities under the energy control procedure being inspected, and the elements set forth in paragraph (c)(7)(ii) of this section: a. On or about June 26, 2019, the periodic inspections from 2017 & 2018 of the Lockout / Tagout program for the machinery on coating line two was not conducted for each authorized employee that works and or performs maintenance on the machinery for coating line two.

Date of last update: 01 Mar 2025

Sources: Florida Department of State