Entity Name: | SILVA TILE & MARBLE, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
SILVA TILE & MARBLE, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 30 Oct 2000 (25 years ago) |
Document Number: | P00000102089 |
FEI/EIN Number |
593678161
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 2099 SAGEBRUSH CIRCLE, NAPLES, FL, 34120, US |
Mail Address: | 2099 SAGEBRUSH CIRCLE, NAPLES, FL, 34120, US |
ZIP code: | 34120 |
County: | Collier |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
SILVA JENFRIT NJR | President | 2099 SAGEBRUSH CIRCLE, NAPLES, FL, 34120 |
SILVA CAROLINE J | Secretary | 2099 SAGEBRUSH CIRCLE, NAPLES, FL, 34120 |
SILVA CHRISTOPHER D | Vice President | 2099 SAGEBRUSH CIRCLE, NAPLES, FL, 34120 |
SILVA JENFRIT NJR | Agent | 2099 SAGEBRUSH CIRCLE, NAPLES, FL, 34120 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2020-06-15 | 2099 SAGEBRUSH CIRCLE, NAPLES, FL 34120 | - |
CHANGE OF MAILING ADDRESS | 2020-06-15 | 2099 SAGEBRUSH CIRCLE, NAPLES, FL 34120 | - |
REGISTERED AGENT ADDRESS CHANGED | 2020-06-15 | 2099 SAGEBRUSH CIRCLE, NAPLES, FL 34120 | - |
REGISTERED AGENT NAME CHANGED | 2011-04-29 | SILVA, JENFRIT N, JR | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-02-11 |
ANNUAL REPORT | 2023-03-07 |
ANNUAL REPORT | 2022-03-25 |
ANNUAL REPORT | 2021-02-23 |
ANNUAL REPORT | 2020-06-15 |
ANNUAL REPORT | 2019-04-06 |
ANNUAL REPORT | 2018-02-21 |
ANNUAL REPORT | 2017-04-18 |
ANNUAL REPORT | 2016-03-25 |
ANNUAL REPORT | 2015-02-24 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
341810372 | 0418800 | 2016-09-28 | 675 2ND STREET SOUTH, NAPLES, FL, 34102 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2017-01-03 |
Current Penalty | 2672.0 |
Initial Penalty | 2672.0 |
Final Order | 2017-01-31 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about 9/28/2016, an employee cleaning an upper deck of a residential home was exposed to a fall hazard due to lack of fall protection system. |
Citation ID | 02001A |
Citaton Type | Other |
Standard Cited | 19101200 E01 |
Issuance Date | 2017-01-03 |
Abatement Due Date | 2017-01-30 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-01-31 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about 9/28/2016, the employer did not develop a written hazard communication program while employees used a waterproofing sealant (Vulkem 350 NF), which the SDS was not available at the jobsite. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
Citation ID | 02001B |
Citaton Type | Other |
Standard Cited | 19101200 G08 |
Issuance Date | 2017-01-03 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-01-31 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area: On or about 9/28/2016, the employer did not have a copy of the safety data sheet for a waterproofing sealant (Vulkem 350 NF), which an employee was using on a 2nd floor deck. |
Date of last update: 03 Apr 2025