339017105
|
0420600
|
2013-04-17
|
10166 CELTIC ASH DR., RIVERVIEW, FL, 33569
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-04-17
|
Emphasis |
L: EISAX, P: FALL, L: FALL, L: EISAOF
|
Case Closed |
2013-07-02
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2013-06-24 |
Current Penalty |
734.4 |
Initial Penalty |
1224.0 |
Final Order |
2013-07-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) (a) At the site - employees were observed stuccoing from a tubular welded frame scaffold system that was not fully planked. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260451 B02 |
Issuance Date |
2013-06-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-07-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: (a) At the site - employees were observed stuccoing from a bridge within a trestle type scaffold frame that was not 18 inches wide. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260451 F03 |
Issuance Date |
2013-06-24 |
Abatement Due Date |
2013-07-05 |
Current Penalty |
486.0 |
Initial Penalty |
810.0 |
Final Order |
2013-07-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: (a) At the site - the employer did not conduct a pre-shift inspection to ensure that employees stuccoing from a bridge supported by a trestle type scaffold frame was at least 18 inches wide. (b) At the site - the employer did not conduct a pre-shift inspection to ensure that the employees observed stuccoing from a tubular welded frame scaffold system was fully planked. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260451 F04 |
Issuance Date |
2013-06-24 |
Abatement Due Date |
2013-07-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-07-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(4): Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired. (a) At the site - the employer did not conduct a pre-shift inspection to take equipment out of service that was damaged. Employees were observed stuccoing from a bridge supported by a trussle type scaffold frame that damaged. |
|
|
339017121
|
0420600
|
2013-04-17
|
10041 SMARTY JONES AVE., GIBSONTON, FL, 33534
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-04-17
|
Emphasis |
L: EISAOF, L: FALL, P: FALL, L: EISAX
|
Case Closed |
2013-07-02
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2013-06-14 |
Abatement Due Date |
2013-06-14 |
Current Penalty |
1101.6 |
Initial Penalty |
1836.0 |
Final Order |
2013-07-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): (a) At the site - employees were observed applying stucco from a tubular welded frame scaffold platform that was not fully planked were exposed to a 12 foot fall. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 B02 |
Issuance Date |
2013-06-14 |
Abatement Due Date |
2013-06-14 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-07-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: (a) At the site - employees were observed applying stucco to a building from a bridge located within a tubular welded frame scaffold platform which was not 18 inches wide. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 I |
Issuance Date |
2013-06-14 |
Abatement Due Date |
2013-06-14 |
Current Penalty |
1224.0 |
Initial Penalty |
2040.0 |
Final Order |
2013-07-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement: (a) At the site - employees were observed aplplying stucco to a building from a tubular welded frame scaffold platform. The legs of the scaffold were not supported by mudsills, in that, the mud sills were not placed directly under the complete pad of the screw jacks. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2013-06-14 |
Abatement Due Date |
2013-06-14 |
Current Penalty |
1101.6 |
Initial Penalty |
1836.0 |
Final Order |
2013-07-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. (a) At the site - employees were observed climbing the scaffold components to access the work platform of the tubular welded frame scaffold |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2013-06-14 |
Abatement Due Date |
2013-06-14 |
Current Penalty |
1101.6 |
Initial Penalty |
1836.0 |
Final Order |
2013-07-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. (a) At the site - employees were exposed to a 12 foot fall while stuccoing a building from a tubular welded frame scaffold platform that was missing guardrails. |
|
|
311823124
|
0419700
|
2009-08-20
|
JUST SOUTH OF 393 3RD ST N, JACKSONVILLE BEACH, FL, 32250
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2009-08-20
|
Emphasis |
L: FALL, S: COMMERCIAL CONSTR, S: FALL FROM HEIGHT
|
Case Closed |
2009-10-24
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2009-09-03 |
Abatement Due Date |
2009-09-09 |
Current Penalty |
800.0 |
Initial Penalty |
800.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 H02 |
Issuance Date |
2009-09-03 |
Abatement Due Date |
2009-09-09 |
Current Penalty |
600.0 |
Initial Penalty |
600.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
|
310032404
|
0419700
|
2007-07-02
|
1996 MAYPORT ROAD, JACKSONVILLE, FL, 32259
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2007-07-06
|
Emphasis |
S: POWERED IND VEHICLE, S: STRUCK-BY, S: FALL FROM HEIGHT, S: COMMERCIAL CONSTR, L: OHPWRLNE, L: FALL, S: ELECTRICAL
|
Case Closed |
2007-09-17
|
Related Activity
Type |
Referral |
Activity Nr |
201356656 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2007-08-20 |
Abatement Due Date |
2007-08-23 |
Current Penalty |
1000.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
|
|