Search icon

G & S STUCCO, CORP. - Florida Company Profile

Company Details

Entity Name: G & S STUCCO, CORP.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

G & S STUCCO, CORP. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 02 Aug 2000 (25 years ago)
Date of dissolution: 15 Feb 2010 (15 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 15 Feb 2010 (15 years ago)
Document Number: P00000074625
FEI/EIN Number 593664066

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2482 ANNISTON RD, JACKSONVILLE, FL, 32246
Mail Address: 2482 ANNISTON RD, JACKSONVILLE, FL, 32246
ZIP code: 32246
County: Duval
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
STATE GHEORGHE President 2482 ANNISTON RD, JACKSONVILLE, FL, 32246
STATE SEVENY M Secretary 2482 ANNISTON RD, JACKSONVILLE, FL, 32246
STATE SEVENY Agent 2482 ANNISTON RD, JACKSONVILLE, FL, 32246

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G08305900192 G&S DESIGN AND CONSTRUCTION SERVICES EXPIRED 2008-10-31 2013-12-31 - 2482 ANNISTON ROAD, JACKSONVILLE, FL, 32246

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2010-02-15 - -
CHANGE OF PRINCIPAL ADDRESS 2009-04-20 2482 ANNISTON RD, JACKSONVILLE, FL 32246 -
CHANGE OF MAILING ADDRESS 2009-04-20 2482 ANNISTON RD, JACKSONVILLE, FL 32246 -
REGISTERED AGENT NAME CHANGED 2009-04-20 STATE, SEVENY -
REGISTERED AGENT ADDRESS CHANGED 2009-04-20 2482 ANNISTON RD, JACKSONVILLE, FL 32246 -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J11000110457 LAPSED 1000000204187 DUVAL 2011-02-16 2021-02-23 $ 2,086.22 STATE OF FLORIDA, DEPARTMENT OF REVENUE, JACKSONVILLE SERVICE CENTER, 921 N DAVIS ST STE 250A, JACKSONVILLE FL322096825

Documents

Name Date
Voluntary Dissolution 2010-02-15
ANNUAL REPORT 2009-04-20
ANNUAL REPORT 2008-05-01
ANNUAL REPORT 2007-04-29
ANNUAL REPORT 2006-01-06
ANNUAL REPORT 2005-08-02
ANNUAL REPORT 2004-07-26
ANNUAL REPORT 2003-01-30
ANNUAL REPORT 2002-02-06
ANNUAL REPORT 2001-04-10

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339017105 0420600 2013-04-17 10166 CELTIC ASH DR., RIVERVIEW, FL, 33569
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-04-17
Emphasis L: EISAX, P: FALL, L: FALL, L: EISAOF
Case Closed 2013-07-02

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2013-06-24
Current Penalty 734.4
Initial Penalty 1224.0
Final Order 2013-07-02
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) (a) At the site - employees were observed stuccoing from a tubular welded frame scaffold system that was not fully planked.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2013-06-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-07-02
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: (a) At the site - employees were observed stuccoing from a bridge within a trestle type scaffold frame that was not 18 inches wide.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2013-06-24
Abatement Due Date 2013-07-05
Current Penalty 486.0
Initial Penalty 810.0
Final Order 2013-07-02
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: (a) At the site - the employer did not conduct a pre-shift inspection to ensure that employees stuccoing from a bridge supported by a trestle type scaffold frame was at least 18 inches wide. (b) At the site - the employer did not conduct a pre-shift inspection to ensure that the employees observed stuccoing from a tubular welded frame scaffold system was fully planked.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 F04
Issuance Date 2013-06-24
Abatement Due Date 2013-07-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-07-02
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(4): Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired. (a) At the site - the employer did not conduct a pre-shift inspection to take equipment out of service that was damaged. Employees were observed stuccoing from a bridge supported by a trussle type scaffold frame that damaged.
339017121 0420600 2013-04-17 10041 SMARTY JONES AVE., GIBSONTON, FL, 33534
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-04-17
Emphasis L: EISAOF, L: FALL, P: FALL, L: EISAX
Case Closed 2013-07-02

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2013-06-14
Abatement Due Date 2013-06-14
Current Penalty 1101.6
Initial Penalty 1836.0
Final Order 2013-07-02
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): (a) At the site - employees were observed applying stucco from a tubular welded frame scaffold platform that was not fully planked were exposed to a 12 foot fall.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2013-06-14
Abatement Due Date 2013-06-14
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2013-07-02
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: (a) At the site - employees were observed applying stucco to a building from a bridge located within a tubular welded frame scaffold platform which was not 18 inches wide.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 C02 I
Issuance Date 2013-06-14
Abatement Due Date 2013-06-14
Current Penalty 1224.0
Initial Penalty 2040.0
Final Order 2013-07-02
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement: (a) At the site - employees were observed aplplying stucco to a building from a tubular welded frame scaffold platform. The legs of the scaffold were not supported by mudsills, in that, the mud sills were not placed directly under the complete pad of the screw jacks.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2013-06-14
Abatement Due Date 2013-06-14
Current Penalty 1101.6
Initial Penalty 1836.0
Final Order 2013-07-02
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. (a) At the site - employees were observed climbing the scaffold components to access the work platform of the tubular welded frame scaffold
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2013-06-14
Abatement Due Date 2013-06-14
Current Penalty 1101.6
Initial Penalty 1836.0
Final Order 2013-07-02
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. (a) At the site - employees were exposed to a 12 foot fall while stuccoing a building from a tubular welded frame scaffold platform that was missing guardrails.
311823124 0419700 2009-08-20 JUST SOUTH OF 393 3RD ST N, JACKSONVILLE BEACH, FL, 32250
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2009-08-20
Emphasis L: FALL, S: COMMERCIAL CONSTR, S: FALL FROM HEIGHT
Case Closed 2009-10-24

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2009-09-03
Abatement Due Date 2009-09-09
Current Penalty 800.0
Initial Penalty 800.0
Nr Instances 1
Nr Exposed 1
Gravity 02
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 H02
Issuance Date 2009-09-03
Abatement Due Date 2009-09-09
Current Penalty 600.0
Initial Penalty 600.0
Nr Instances 1
Nr Exposed 1
Gravity 01
310032404 0419700 2007-07-02 1996 MAYPORT ROAD, JACKSONVILLE, FL, 32259
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2007-07-06
Emphasis S: POWERED IND VEHICLE, S: STRUCK-BY, S: FALL FROM HEIGHT, S: COMMERCIAL CONSTR, L: OHPWRLNE, L: FALL, S: ELECTRICAL
Case Closed 2007-09-17

Related Activity

Type Referral
Activity Nr 201356656
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2007-08-20
Abatement Due Date 2007-08-23
Current Penalty 1000.0
Initial Penalty 1500.0
Nr Instances 1
Nr Exposed 1
Gravity 10

Date of last update: 02 Apr 2025

Sources: Florida Department of State