Search icon

FLORIDA LEMARK CORPORATION - Florida Company Profile

Company Details

Entity Name: FLORIDA LEMARK CORPORATION
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

FLORIDA LEMARK CORPORATION is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 24 Mar 1987 (38 years ago)
Last Event: AMENDMENT
Event Date Filed: 29 Aug 2022 (3 years ago)
Document Number: M48901
FEI/EIN Number 592784516

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 8750 NW 36 Street, Suite 200, Doral, FL, 33178, US
Mail Address: 8750 NW 36 Street, Suite 200, Doral, FL, 33178, US
ZIP code: 33178
County: Miami-Dade
Place of Formation: FLORIDA

form 5500

Plan Name Plan Year EIN/PN Received Sponsor Total number of participants
FLORIDA LEMARK CORPORATION 401(K) P/S PLAN 2023 592784516 2024-06-20 FLORIDA LEMARK CORPORATION 141
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2023-01-01
Business code 551112
Sponsor’s telephone number 3055931442
Plan sponsor’s address 8750 NW 36TH ST STE 200, DORAL, FL, 33178

Signature of

Role Plan administrator
Date 2024-06-20
Name of individual signing MARIA RODRIGUEZ
Valid signature Filed with authorized/valid electronic signature

Key Officers & Management

Name Role Address
RODRIGUEZ LINDA Vice President 8750 NW 36 Street, Doral, FL, 33178
RODRIGUEZ EMILIO President 8750 NW 36 Street, Doral, FL, 33178
RODRIGUEZ EDUARDO P Vice President 8750 NW 36 Street, Doral, FL, 33178
RODRIGUEZ MARCOS A Vice President 8750 NW 36 Street, Doral, FL, 33178
RODRIGUEZ MARIA Vice President 8750 NE 36TH ST., SUITE 200, DORAL, FL, 33178
LUPINO JAMES SEsq. Agent Hershoff Lupino & Yagel, LLP, Miami, FL, 33156

Events

Event Type Filed Date Value Description
AMENDMENT 2022-08-29 - -
REGISTERED AGENT ADDRESS CHANGED 2022-04-29 Hershoff Lupino & Yagel, LLP, 9350 S Dixie Highway, Suite 1470, Miami, FL 33156 -
CHANGE OF PRINCIPAL ADDRESS 2021-02-25 8750 NW 36 Street, Suite 200, Doral, FL 33178 -
CHANGE OF MAILING ADDRESS 2021-02-25 8750 NW 36 Street, Suite 200, Doral, FL 33178 -
REGISTERED AGENT NAME CHANGED 2021-02-25 LUPINO, JAMES S, Esq. -
AMENDMENT 1995-10-30 - -
REINSTATEMENT 1993-05-03 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 1992-10-09 - -

Documents

Name Date
ANNUAL REPORT 2024-02-05
ANNUAL REPORT 2023-01-25
Amendment 2022-08-29
ANNUAL REPORT 2022-04-29
ANNUAL REPORT 2021-02-25
ANNUAL REPORT 2020-01-28
ANNUAL REPORT 2019-03-13
ANNUAL REPORT 2018-01-24
ANNUAL REPORT 2017-01-23
ANNUAL REPORT 2016-01-25

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343300836 0418800 2018-07-13 1121 CRANDON BOULEVARD, KEY BISCAYNE, FL, 33149
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-07-13
Emphasis L: FALL
Case Closed 2022-07-25

Related Activity

Type Referral
Activity Nr 1357666
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2019-01-07
Abatement Due Date 2019-02-01
Current Penalty 0.0
Initial Penalty 12934.0
Contest Date 2019-02-01
Final Order 2019-09-25
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about July 11, 2017, at 1121 Crandon Boulevard, Key Biscayne, Florida, employees were exposed to a fall hazard while operating a two-point suspension scaffold that was not inspected for deteriorated and torn protective covers over the ascent and descent switches on two of its hoist motors. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2019-01-07
Abatement Due Date 2019-02-01
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2019-02-01
Final Order 2019-09-25
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration; Such activities were not performed only by experienced and trained employees selected for such work by the competent person: On or about July 11, 2017, at 1121 Crandon Boulevard, Key Biscayne, Florida, the employer failed to disassemble, assemble, and move a two-point suspension scaffold under the supervision and direction of a competent person for employees to apply stucco, paint and water proofing to the exterior of an existing 12 story high-rise condominium building, thus exposing the workers to a fall hazard. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260454 B
Issuance Date 2019-01-07
Abatement Due Date 2019-02-01
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2019-02-01
Final Order 2019-09-25
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: On or about July 11, 2017, at 1121 Crandon Boulevard, Key Biscayne, Florida, the employer failed to have a competent person train employees who disassembled and assembled a two-point suspension scaffold to recognize hazards associated the equipment, while employees operated the equipment to apply stucco, paint and water proofing to the exterior walls of an existing 12-story high-rise condominium building, thus exposing the workers to a fall hazard. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
343114906 0418800 2018-04-26 18001 OLD CUTLER RD, PALMETTO BAY, FL, 33157
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-04-26
Emphasis L: FALL
Case Closed 2018-11-14

Related Activity

Type Referral
Activity Nr 1331247
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260451 F03
Issuance Date 2018-10-22
Abatement Due Date 2018-11-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-11-13
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about April 25, 2018, at the above referenced job site, on the West side of the building, employees were exposed to a fall hazard while using a swing stage scaffold without conducting a safety check as directed in the manufacturer owner's manual.
Citation ID 01002
Citaton Type Other
Standard Cited 19260454 A
Issuance Date 2018-10-22
Abatement Due Date 2018-11-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-11-13
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold(s) trained by a person qualified in the subject matter to recognize those hazards associated with the type of scaffold(s) being used and to understand the pr: On or about April 25, 2018, at the above referenced job site, on the West side of the building, employees were exposed to a fall hazard while using a swing stage scaffold without the proper training as directed in the manufacturer owner's manual.
341247310 0418800 2016-02-05 215 S. 8TH AVENUE, FORT LAUDERDALE, FL, 33301
Inspection Type Planned
Scope NoInspection
Safety/Health Health
Close Conference 2016-02-05
Emphasis N: SILICA, P: SILICA
Case Closed 2016-05-20
339151417 0420600 2013-06-26 708 W. HOWARD AVE., TAMPA, FL, 33608
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2013-06-26
Emphasis L: FALL, P: FALL
Case Closed 2013-11-22

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100134 K
Issuance Date 2013-08-07
Abatement Due Date 2013-08-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-09-16
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: (a) At the site - employee was observed wearing a Aaron 3475 dust mask that was not properly worn while applying Sikaflex 2 Sealant to the concrete walls.
337060586 0418800 2012-10-10 3800 NW 115TH AVE., DORAL, FL, 33178
Inspection Type Unprog Other
Scope Complete
Safety/Health Safety
Close Conference 2012-10-10
Case Closed 2017-06-20

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2013-04-09
Abatement Due Date 2013-04-26
Current Penalty 6300.0
Initial Penalty 6300.0
Contest Date 2013-04-29
Final Order 2016-03-10
Nr Instances 1
Nr Exposed 120
Gravity 10
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees when they were exposed to struck-by and caught-in-between hazards: On or about 10/10/2012, at the above addressed jobsite, employees were exposed to the hazard of being struck-by and caught-in-between collapsing pre-cast structural members due to not performing grouting of the bases of columns B-3 and A-3.3. Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow the grout application instructions as per Coreslab Erection Drawings E0.0 General Notes, Section 3.4 Grout and Solar Erector's erection procedure in the column section, item # 4. NOTE: ABATEMENT CERTIFICATION AND DOCUMENTATION IS REQUIRED FOR THIS ITEM.
316327519 0418800 2012-03-28 45 W 6TH STREET, HIALEAH, FL, 33010
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-03-28
Emphasis L: FALL
Case Closed 2012-03-30
315353540 0418800 2011-05-19 1766 BISCAYNE BLVD, MIAMI, FL, 33132
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2011-10-18
Case Closed 2012-04-18

Related Activity

Type Referral
Activity Nr 202883120
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260020 B02
Issuance Date 2011-10-24
Abatement Due Date 2011-11-03
Current Penalty 2800.0
Initial Penalty 2800.0
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 05
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 C03
Issuance Date 2011-10-24
Abatement Due Date 2011-11-03
Current Penalty 2800.0
Initial Penalty 2800.0
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 05
314268582 0418800 2011-01-10 205 LA PALOMA ROAD, KEY LARGO, FL, 33037
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2011-01-10
Emphasis L: FALL
Case Closed 2011-11-07

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260021 B02
Issuance Date 2011-01-27
Abatement Due Date 2011-02-08
Current Penalty 3500.0
Initial Penalty 3500.0
Contest Date 2011-02-18
Final Order 2011-10-11
Nr Instances 1
Nr Exposed 3
Gravity 05
Citation ID 01002
Citaton Type Other
Standard Cited 19261052 C01
Issuance Date 2011-01-27
Abatement Due Date 2011-02-01
Current Penalty 2800.0
Initial Penalty 2800.0
Contest Date 2011-02-18
Final Order 2011-10-11
Nr Instances 1
Nr Exposed 4
Gravity 05
307302067 0418800 2004-08-18 441 AND WINSTON PARK DRIVE, COCONUT CREEK, FL, 33073
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2004-08-18
Case Closed 2004-12-29

Related Activity

Type Inspection
Activity Nr 307301622

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100178 L01 I
Issuance Date 2004-09-29
Abatement Due Date 2004-10-19
Current Penalty 1000.0
Initial Penalty 1400.0
Contest Date 2004-10-22
Final Order 2004-12-22
Nr Instances 1
Nr Exposed 1
Gravity 05
305495004 0418800 2002-03-18 331 7TH STREET, FT LAUDERDALE, FL, 33301
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2002-03-20
Emphasis L: FALL, L: FLCARE
Case Closed 2002-12-06

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260501 B01
Issuance Date 2002-07-16
Abatement Due Date 2002-07-22
Current Penalty 500.0
Initial Penalty 2500.0
Contest Date 2002-08-08
Final Order 2002-11-14
Nr Instances 1
Nr Exposed 1
Gravity 10
Inspection Type Unprog Rel
Scope Complete
Safety/Health Safety
Close Conference 2001-07-19
Emphasis L: FLCARE, S: CONSTRUCTION
Case Closed 2001-12-14

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260200 B01
Issuance Date 2001-07-23
Abatement Due Date 2001-08-02
Current Penalty 1071.43
Initial Penalty 1500.0
Contest Date 2001-08-15
Final Order 2001-11-19
Nr Instances 1
Nr Exposed 3
Gravity 10
Hazard STRUCK BY
Inspection Type Prog Other
Scope Complete
Safety/Health Health
Close Conference 2001-02-09
Emphasis L: FALL, L: FLCARE
Case Closed 2001-07-19

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260502 D21
Issuance Date 2001-06-28
Abatement Due Date 2001-07-03
Current Penalty 1875.0
Initial Penalty 2500.0
Nr Instances 1
Nr Exposed 2
Gravity 10
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260502 E04
Issuance Date 2001-06-28
Abatement Due Date 2001-07-05
Nr Instances 1
Nr Exposed 2
Gravity 10
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260503 C
Issuance Date 2001-06-28
Abatement Due Date 2001-07-25
Nr Instances 1
Nr Exposed 2
Gravity 10
Inspection Type Unprog Rel
Scope Complete
Safety/Health Safety
Close Conference 2000-12-01
Emphasis L: FLCARE, L: FALL
Case Closed 2001-02-01

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
4068527405 2020-05-08 0455 PPP 9627 S Dixie Hwy, Miami, FL, 33156
Loan Status Date 2021-10-19
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 44700
Loan Approval Amount (current) 44700
Undisbursed Amount 0
Franchise Name -
Lender Location ID 225134
Servicing Lender Name Truist Bank
Servicing Lender Address 214 N Tryon St, CHARLOTTE, NC, 28202-1078
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address Miami, MIAMI-DADE, FL, 33156
Project Congressional District FL-27
Number of Employees 3
NAICS code 531110
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 225134
Originating Lender Name Truist Bank
Originating Lender Address CHARLOTTE, NC
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 45279.86
Forgiveness Paid Date 2021-09-28

Date of last update: 01 Mar 2025

Sources: Florida Department of State