Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 C01 |
Issuance Date |
2013-06-28 |
Abatement Due Date |
2013-07-22 |
Current Penalty |
1200.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-07-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: a) Sancrete Extruder Machine -Gantry Cement Bucket Receiving Platform: for the employee(s) working from the platform in which the chain used in lieu of a guardrail was not attached at the receiving area exposing the employee to a fall of approximately 15 feet to the ground, or hopper, as observed on or about 04/18/13. Note. Each opening requires both a top and mid-rail (chain). |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100147 C04 II |
Issuance Date |
2013-06-28 |
Abatement Due Date |
2013-07-17 |
Current Penalty |
500.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-07-23 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a) Plant - Maintenance Department - The lockout/tagout program did not list specific procedural steps for the location and identification of all energy sources to be shut down, isolated, blocked and the securing of specific machines and equipment such as but not limited to the extruder, mixer, forklift, saws and conveyor belt in order to control hazardous energy, as noted on or about 04/18/13. |
|
Citation ID |
01003A |
Citaton Type |
Other |
Standard Cited |
19100178 A06 |
Issuance Date |
2013-06-28 |
Abatement Due Date |
2013-07-22 |
Current Penalty |
500.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-07-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(a)(6): The employer did not ensure that all name plates or markings were maintained in a legible condition: a) Yard Area - Gradall Diesel Powered Forklift # 531: The forklift capacity plates were illegible due to a heavy build-up of cement residue, as observed on or about 03/13/13. |
|
Citation ID |
01003B |
Citaton Type |
Other |
Standard Cited |
19100178 P01 |
Issuance Date |
2013-06-28 |
Abatement Due Date |
2013-07-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-07-23 |
Nr Instances |
3 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s) a) Yard Area - Taylor Forklift # 531: The forklift was not taken out of service for an inoperable horn, on or about 03/13/13. b) Yard Area - Gradall Forklift # 533 Model # 534C-9: The forklift was not taken out of service for an inoperable overhead left light lense. c) Yard Area - Gradall Forklift # 533 Model # 534C-9: The brake pedal did not function properly. As observed on or about 04/18/13, when the brake inching travel pedal was depressed, the pedal dropped to the floor and had to be lifted up by hand to reset the brake in its normal position. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 I |
Issuance Date |
2013-06-28 |
Abatement Due Date |
2013-07-25 |
Current Penalty |
1000.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-07-23 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Throughout plant - Taylor & Gradall Diesel Forklifts: Two of the forklift operators were operating forklifts without receiving forklift training as required by the standard, as noted on or about 03/13/13. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100178 L04 III |
Issuance Date |
2013-06-28 |
Abatement Due Date |
2013-07-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-07-23 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) Throughout Plant: Forklift operators who received training in 05/09 did not receive the required re-evaluation, as noted on or about 03/13/13. |
|
Citation ID |
01005A |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2013-06-28 |
Abatement Due Date |
2013-08-15 |
Current Penalty |
0.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-07-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by numerous unguarded machine components within frame of machine. a) Yard Area - for the Sancrete Extruder Machine Model # GT 120: In that there were numerous unguarded machine components within the frame of the machine. Potential contact points included but is not limited to: reciprocating arms, the trowel, and the tamp, as observed on or about 04/18/13. |
|
Citation ID |
01005B |
Citaton Type |
Serious |
Standard Cited |
19100219 C02 I |
Issuance Date |
2013-06-28 |
Abatement Due Date |
2013-08-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-07-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) Yard Area - Sancrete Extruder Machine Model # GT 120: for the unguarded rotating shaft which drives the trowel and tamp within the frame of the extruder, as observed on or about 04/18/13. |
|
Citation ID |
01005C |
Citaton Type |
Serious |
Standard Cited |
19100219 F03 |
Issuance Date |
2013-06-28 |
Abatement Due Date |
2013-07-25 |
Current Penalty |
1200.0 |
Initial Penalty |
0.0 |
Final Order |
2013-07-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(f)(3): Sprockets and chains. All sprocket wheels and chains shall be enclosed unless they are more than seven (7) feet above the floor or platform. Where the drive extends over other machine or working areas, protection against falling shall be provided. This subparagraph does not apply to manually operated sprockets. a) Plant - Spancrete Extruder Machine - Model # GT 120: for the unguarded chain & sprocket drive within frame of machine, as observed on or about 04/18/13. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100179 J02 II |
Issuance Date |
2013-06-28 |
Abatement Due Date |
2013-07-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-07-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.179(j)(2)(ii): Frequent crane inspections did not determine the presence of a hydraulic oil leak: a) Yard Area - Mi-Jack Gantry Crane MIJ 512 Model# 650C: for the hydraulic oil leak at the wheel pivotal area, as observed on or about 04/18/13. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100303 B01 |
Issuance Date |
2013-06-28 |
Abatement Due Date |
2013-07-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-07-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a) Yard Area - West Side Pit Area: The Ryobi Portable Saw (SN G0530-55042) was being used with torn and cut power cord insulation, as observed on or about 03/13/13. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100305 E01 |
Issuance Date |
2013-06-28 |
Abatement Due Date |
2013-07-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-07-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures were not weatherproof in wet locations: a) Yard Area - West Side Pit Area: - in that the weather proof outlet was missing the cover, as observed on or about 03/13/13. |
|