Search icon

ROCKET CARWASH, LLC - Florida Company Profile

Company Details

Entity Name: ROCKET CARWASH, LLC
Jurisdiction: FLORIDA
Filing Type: Foreign Limited Liability Co.
Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 01 Dec 2021 (3 years ago)
Document Number: M21000016345
FEI/EIN Number 852259620

Federal Employer Identification (FEI) Number assigned by the IRS.

Mail Address: PO BOX 241468, OMAHA, NE, 68124, US
Address: 222 S 15TH ST, STE 1404S, OMAHA, NE, 68102, US
Place of Formation: NEBRASKA

Key Officers & Management

Name Role Address
CITY+VENTURES ENTERPRISES Manager PO BOX 241468, OMAHA, NE, 68124
CAPITOL CORPORATE SERVICES, INC. Agent -

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2024-04-25 222 S 15TH ST, STE 1404S, OMAHA, NE 68102 -
CHANGE OF MAILING ADDRESS 2022-04-26 222 S 15TH ST, STE 1404S, OMAHA, NE 68102 -

Documents

Name Date
ANNUAL REPORT 2024-04-25
ANNUAL REPORT 2023-04-27
ANNUAL REPORT 2022-04-26
Foreign Limited 2021-12-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347425480 0418600 2024-04-18 789 WEST 9 MILE ROAD, PENSACOLA, FL, 32534
Inspection Type Complaint
Scope Complete
Safety/Health Health
Close Conference 2024-04-18
Case Closed 2024-10-23

Related Activity

Type Complaint
Activity Nr 2152534
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100147 C01
Issuance Date 2024-09-13
Abatement Due Date 2024-10-11
Current Penalty 6914.4
Initial Penalty 11524.0
Final Order 2024-10-15
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) Carwash: On or about April 12, 2024, and at times prior thereto the employer exposed employees to amputation, caught-in and struck-by hazards from vehicle conveyor chain due to employers' failure to establish a program consisting of an energy control procedure, employee training and periodic inspections for the purpose of controlling hazardous energy sources for employees servicing, repairing and cleaning carwash equipment.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100147 C04 I
Issuance Date 2024-09-13
Abatement Due Date 2024-10-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-10-15
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Carwash: On or about April 12, 2024, and at times prior thereto the employer exposed its employees to potential hazardous energies in that employees were allowed to work equipment such as but not limited to automatic carwash roller system which has multiple energy sources such as electric, pneumatic and hydraulic without having a written machine specific lock out procedure to ensure that those energy sources were controlled while the employees were performing maintenance or servicing.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100147 C05 I
Issuance Date 2024-09-13
Abatement Due Date 2024-10-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-10-15
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing, or blocking of machines or equipment from energy sources: (a) Carwash: On or about April 12, 2024 and at times prior thereto the employer exposed employees to potential hazardous energies in that the employer had not provided authorized employees locks for isolating and securing machine energy sources.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100147 C07 I
Issuance Date 2024-09-13
Abatement Due Date 2024-10-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-10-15
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) Carwash: On or about April 12, 2024, and at times prior thereto the employer exposed employees to potential hazardous energies in that employees were allowed to work on automatic carwash equipment without first being trained to ensure those employees had the knowledge and skills for the safe application, usage, and removal of energy controls.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100303 G01 II
Issuance Date 2024-09-13
Abatement Due Date 2024-10-11
Current Penalty 6914.4
Initial Penalty 11524.0
Final Order 2024-10-15
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less is used for storage: a) Motor Control and Storage Room; On or about April 12, 2024, and at times prior thereto the employer exposed employees to electrical hazards in that clear access was not maintained in front of electrical control and breaker panels.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100305 B02 I
Issuance Date 2024-09-13
Abatement Due Date 2024-10-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-10-15
Nr Instances 1
Nr Exposed 14
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(2)(i):Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a) Automatic carwash tunnel, On or about April 18, 2024 and at times prior thereto the employer exposed employees to electrical hazards in that employees were allowed to walk and work around a metal electrical junction box with out a cover in place.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19100332 B01
Issuance Date 2024-09-13
Abatement Due Date 2024-10-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-10-15
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.332(b)(1):Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: a) Motor Control Room; On or about April 18, 2024, and at times prior thereto the employer exposed employees to electrical hazards in that employees were required to open electrical panels to turn on and off and replace relays and breakers exposing themselves to live parts operating at 120 volts without first being trained in electrical safety-related work practices.
Citation ID 02001
Citaton Type Other
Standard Cited 19100030 B01
Issuance Date 2024-09-13
Abatement Due Date 2024-10-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-10-15
Nr Instances 1
Nr Exposed 14
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.30(b)(1): The employer did not train each employee on or before May 17, 2017 in the proper care, inspection, storage, and use of equipment covered by this subpart before an employee uses the equipment. a) Facility ; On or about April 18, 2024 the employer allowed employees to use a 4ft ladder to perform maintenance tasks in the workplace without first training the employees to recognize hazards related to ladders use and training them on the proper care, inspection, storage, and use of the ladder. Ladder Training
Citation ID 02002
Citaton Type Other
Standard Cited 19100037 B05
Issuance Date 2024-09-13
Abatement Due Date 2024-10-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-10-15
Nr Instances 1
Nr Exposed 14
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.37(b)(5):Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): a) Motor control/storage room; On or about April 18, 2024 and at times prior thereto the employer failed ensure the door leading from the motor control/storage room into the automatic carwash was marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use.
Citation ID 02003A
Citaton Type Other
Standard Cited 19100157 E03
Issuance Date 2024-09-13
Abatement Due Date 2024-10-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-10-15
Nr Instances 1
Nr Exposed 14
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.157(e)(3):Portable fire extinguishers were not subjected to an annual maintenance check: a) Office portion of the facility; On or about April 18, 2024; the employer provided employees with portable fire extinguishers for use for fighting incipient stage fires without ensuring the fire extinguishers were subject to a documented annual maintenance check.
Citation ID 02003B
Citaton Type Other
Standard Cited 19100157 G01
Issuance Date 2024-09-13
Abatement Due Date 2024-10-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-10-15
Nr Instances 1
Nr Exposed 14
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.157(g)(1):An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:( a) Facility; On or about April 18, 2024 and at times prior thereto the employer exposed employees to fire hazards in that employees were provided with fire extinguishers for use for fighting incipient stage fires without first being provided training on the principles and hazards involved with fighting incipient stage fires.