Inspection Type |
Unprog Rel
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2023-08-04
|
Related Activity
Type |
Inspection |
Activity Nr |
1688815 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1688816 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 II |
Issuance Date |
2024-02-01 |
Abatement Due Date |
2024-03-20 |
Current Penalty |
14518.0 |
Initial Penalty |
14518.0 |
Contest Date |
2024-02-26 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(ii):Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a) On or about August 4, 2023, and at times prior to, at 2600 Eisenhower Blvd., Fort Lauderdale, FL 33316, South Cross Screw area, employees were exposed to amputation and electrical hazards, in that the employer did not ensure that the lockout/tagout procedure(s) for the south screw described the scope, the type and magnitude of the participating hazardous energies, the location and identity of the disconnecting means, and the specific steps for shutting down and controlling hazardous energy, the placement and removal of lockout/tagout devices, and the testing of equipment during assembly and adjustment. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 I |
Issuance Date |
2024-02-01 |
Abatement Due Date |
2024-03-20 |
Current Penalty |
14518.0 |
Initial Penalty |
14518.0 |
Contest Date |
2024-02-26 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a) On or about August 4, 2023, at 2600 Eisenhower Blvd., Fort Lauderdale, FL 33316, South Cross Screw area, employees were exposed to amputation and electrical hazards, in that the employer did not ensure that periodic inspections of the energy control procedure(s) for the South Cross Screw were performed to prevent accidental contact with nip points, rotating parts, and electrically energized parts. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100147 F02 I |
Issuance Date |
2024-02-01 |
Abatement Due Date |
2024-03-20 |
Current Penalty |
14518.0 |
Initial Penalty |
14518.0 |
Contest Date |
2024-02-26 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(f)(2)(i): When outside servicing personnel were engaged in activities in a facility, the onsite employer and the outside employer did not inform each other of their respective lockout or tagout procedures: a) On or about August 4, 2023, at 2600 Eisenhower Blvd., Fort Lauderdale, FL 33316, South Cross Screw area, employees were exposed to body caught-in and amputation hazards, in that the onsite employer and the outside employer did not review and coordinate in advance the lockout/tagout procedures and the methods for lock removal, power reconnection and controlled rotation of the unguarded screw. |
|
|