347385072
|
0418600
|
2024-04-02
|
289 BULLDOG RD., FREEPORT, FL, 32439
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2024-05-30
|
Case Closed |
2024-10-21
|
Related Activity
Type |
Inspection |
Activity Nr |
1588445 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2024-07-09 |
Abatement Due Date |
2024-09-30 |
Current Penalty |
6465.0 |
Initial Penalty |
10775.0 |
Final Order |
2024-07-29 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that an employee was exposed to potential oxygen deficient atmospheres: a) Refrigeration Mechanical Machine Room: On or about April 2, 2024, and at times prior to, the employer exposed employees to 3700 pounds of anhydrous ammonia inside the refrigeration machine room and did not have safety systems in place such as but not limited to an alarm detection system that is interlocked with mechanical ventilation when employees enter the area for maintenance activities. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100095 G05 I |
Issuance Date |
2024-07-09 |
Abatement Due Date |
2024-07-30 |
Current Penalty |
5171.4 |
Initial Penalty |
8619.0 |
Final Order |
2024-07-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(g)(5)(i):The employer did not establish, within 6 months of an employee's first exposure at or above the action level, a valid baseline audiogram against which subsequent audiograms can be compared: a) Robotic palletizer and bagging system operator : On or about April 5, 20124 and at times prior to, the employer exposed employees to noise dose at levels of 67.9% (equivalent to an 8 hour time weighted average TWA of 87.2 dBA) which is 1.35 times the Action Level of 50% (equivalent to a calculated and corrected TWA of 83.7 dBA) while operating the Hamer Fischbein Model 540A, Serial Number 17540182 Robotic stacker and bagging conveyor system. Results were calculated for a 575-minute sampling period. The employer failed to provide a baseline audiometric test to the employee. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
2024-07-09 |
Abatement Due Date |
2024-07-30 |
Current Penalty |
3878.4 |
Initial Penalty |
6464.0 |
Final Order |
2024-07-29 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c):Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) Mechanical Compressor Area: On or about April 5, 2024, and at times prior, the employer exposed employees to loss of vision and skin burns and rashes, in that there was no approved emergency eyewash in the work area for immediate emergency use while employees performs daily maintenance tasks in the compressor room that contains 3700 pounds of corrosive anhydrous ammonia in the refrigeration system. b) Production Area: On or about April 5, 2024, and at times prior, the employer exposed employees to loss of vision and skin burns and rashes, in that no approved emergency eyewash in the work area for immediate emergency use while employees while performing daily sanitation job tasks of using corrosive sanitizer Meyer-066R in a hand sprayer to sanitize production equipment. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101200 F06 II |
Issuance Date |
2024-07-09 |
Abatement Due Date |
2024-07-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-07-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical. a) Robotic palletizer, conveyor, and bagging production area: On or about April 5, 2024, and at times prior to, the employer did not ensure all secondary containers were labeled with hazard of chemical in 2-gallon hand sprayer that contained Meyer 066R sanitizer liquid used to wash down ice bagging equipment daily. |
|
|
345884456
|
0418600
|
2022-04-05
|
289 BULLDOG RD., FREEPORT, FL, 32439
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2022-04-06
|
Emphasis |
L: HINOISE, N: AMPUTATE
|
Case Closed |
2022-09-15
|
Related Activity
Type |
Referral |
Activity Nr |
1881281 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100095 C01 |
Issuance Date |
2022-06-27 |
Abatement Due Date |
2022-07-08 |
Current Penalty |
3550.0 |
Initial Penalty |
7044.0 |
Final Order |
2022-08-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(c)(1):The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: a) Robotic ice stacker; On or about April 6, 2022 and at times prior to the employer exposed noise at levels 58.9% dose (equivalent to a 8 hour TWA of 86.1 dBA) which is approximately 1.17 times the action level of 50% dose (equivalent to a 12 hour TWA of 82.1). Results are based on 642 minutes sampling period of a 720 minute shift. Exposure calculations included a zero increment for the 78 minute period not sampled. The employer did not administer a continuing, effective hearing conservation program. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100095 D01 |
Issuance Date |
2022-06-27 |
Abatement Due Date |
2022-07-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-08-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: a) Robotic ice stacker; On or about April 6, 2022 and at times prior to the employer exposed noise at levels 58.9% dose (equivalent to a 8 hour TWA of 86.1 dBA) which is approximately 1.17 times the action level of 50% dose (equivalent to a 12 hour TWA of 82.1). Results are based on 642 minutes sampling period of a 720 minute shift. Exposure calculations included a zero increment for the 78 minute period not sampled. The employer did not administer a monitoring program to determine employee exposure to noise. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100095 G01 |
Issuance Date |
2022-06-27 |
Abatement Due Date |
2022-07-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-08-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels: a) Robotic ice stacker; On or about April 6, 2022 and at times prior to the employer exposed noise at levels 58.9% dose (equivalent to a 8 hour TWA of 86.1 dBA) which is approximately 1.17 times the action level of 50% dose (equivalent to a 12 hour TWA of 82.1). Results are based on 642 minutes sampling period of a 720 minute shift. Exposure calculations included a zero increment for the 78 minute period not sampled. The employer did not establish and maintain an audiometric testing program. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2022-06-27 |
Abatement Due Date |
2022-07-08 |
Current Penalty |
3550.0 |
Initial Penalty |
7044.0 |
Final Order |
2022-08-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Accident |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i):Procedures were not developed for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Robotic ice stacker; On or about April 4, 2022 and at times prior to the employer exposed employees to struck-by hazards in that employees were allowed to enter the robotic cell to clear jams without first developing procedures to control hazardous stored energy or inadvertent start up of the machine. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I |
Issuance Date |
2022-06-27 |
Abatement Due Date |
2022-07-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-08-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Accident |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) Robotic ice stacker; On or about April 4, 2022 and at times prior to the employer exposed employees to struck-by hazards in that employees were allowed to enter the robotic cell to clear jams without first being trained on the control of hazardous energies. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19100147 F03 II D |
Issuance Date |
2022-06-27 |
Abatement Due Date |
2022-07-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-08-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Accident |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment: (a) Robotic ice stacker; On or about April 4, 2022 and at times prior to the employer exposed employees to struck-by hazards in that employees were allowed to enter the robotic cell to clear jams without each employee first applying a lockout device to prevent inadvertent start-up. |
|
|
345812648
|
0418800
|
2022-03-03
|
5050 SW 51 STREET, DAVIE, FL, 33314
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-03-03
|
Case Closed |
2022-10-11
|
Related Activity
Type |
Referral |
Activity Nr |
1870605 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2022-08-24 |
Abatement Due Date |
2022-09-30 |
Current Penalty |
3111.0 |
Initial Penalty |
4786.0 |
Final Order |
2022-09-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about March 3, 2022, at the jobsite located at 5050 SW 51 Street Davie, Florida 33314, an employee was exposed to a caught by hazard while performing servicing of an ice bagging machine (i.e. Hamer 525) without being rendered inoperative. |
|
|
344577663
|
0419700
|
2020-01-23
|
4671 EDISON AVE., JACKSONVILLE, FL, 32254
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-04-06
|
Case Closed |
2020-04-27
|
Related Activity
Type |
Referral |
Activity Nr |
1535050 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1457801 |
Safety |
Yes |
|
|
301890489
|
0418800
|
2000-01-05
|
5050 SW 51ST STREET, DAVIE, FL, 33314
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2000-05-16
|
Case Closed |
2000-08-24
|
Related Activity
Type |
Referral |
Activity Nr |
200674794 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2000-06-15 |
Abatement Due Date |
2000-08-12 |
Current Penalty |
657.0 |
Initial Penalty |
875.0 |
Nr Instances |
1 |
Nr Exposed |
20 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
Hazard |
UNAPOPPROC |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2000-06-15 |
Abatement Due Date |
2000-08-02 |
Current Penalty |
657.0 |
Initial Penalty |
875.0 |
Nr Instances |
1 |
Nr Exposed |
20 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
Hazard |
DUST&FUMES |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2000-06-15 |
Abatement Due Date |
2000-07-12 |
Current Penalty |
656.0 |
Initial Penalty |
875.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100147 C05 IID |
Issuance Date |
2000-06-15 |
Abatement Due Date |
2000-07-12 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
02 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100038 A02 |
Issuance Date |
2000-06-15 |
Abatement Due Date |
2000-07-12 |
Current Penalty |
656.0 |
Initial Penalty |
875.0 |
Nr Instances |
1 |
Nr Exposed |
55 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
2000-06-15 |
Abatement Due Date |
2000-07-12 |
Current Penalty |
656.0 |
Initial Penalty |
875.0 |
Nr Instances |
1 |
Nr Exposed |
20 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100120 Q06 IIIA |
Issuance Date |
2000-06-15 |
Abatement Due Date |
2000-09-12 |
Current Penalty |
656.0 |
Initial Penalty |
875.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
|