Search icon

RANCH STUCCO AND MASONRY LLC. - Florida Company Profile

Company Details

Entity Name: RANCH STUCCO AND MASONRY LLC.
Jurisdiction: FLORIDA
Filing Type: Foreign Limited Liability Co.
Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 03 Apr 2015 (10 years ago)
Date of dissolution: 22 Sep 2017 (8 years ago)
Last Event: REVOKED FOR ANNUAL REPORT
Event Date Filed: 22 Sep 2017 (8 years ago)
Document Number: M15000003055
FEI/EIN Number 800888533

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 4509 AMALIE ST., HOUSTON, TX, 77093
Mail Address: P.O. BOX 30562, HOUSTON, TX, 77249
Place of Formation: TEXAS

Key Officers & Management

Name Role Address
GARCILAZO JOSEFINA CSEC 4509 AMALIE ST., HOUSTON, TX, 77093
NRAI, INC. Agent 1200 SOUTH PINE ISLAND ROAD, PLANTATION, FL, 33324

Events

Event Type Filed Date Value Description
REVOKED FOR ANNUAL REPORT 2017-09-22 - -
REINSTATEMENT 2016-10-21 - -
REGISTERED AGENT NAME CHANGED 2016-10-21 NRAI, INC. -
REVOKED FOR ANNUAL REPORT 2016-09-23 - -

Documents

Name Date
REINSTATEMENT 2016-10-21
Foreign Limited 2015-04-03

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341228898 0420600 2016-02-03 22900 LYDEN DRIVE, ESTERO, FL, 33928
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2016-02-03
Emphasis L: FALL, P: FALL
Case Closed 2017-01-06

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2016-03-21
Current Penalty 4200.0
Initial Penalty 4200.0
Final Order 2016-04-20
Nr Instances 2
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a. At the jobsite, the tubular framed walkthrough type scaffolding had 3 boards of planking that covered approximately 28 inches between the uprights leaving an area approximately 11 inches wide without planking, exposing an employee to a 6 foot 11 inch fall hazard, on or about 2/3/16. b. At the jobsite, the folding trestle type scaffolding had a single board of planking that covered approximately 9-1/4 inches between the framing legs leaving an area approximately 16 inches wide without planking, exposing employees to a 5 foot fall hazard, on or about 2/3/16.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 B03 II
Issuance Date 2016-03-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-04-20
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(3)(ii): The maximum distance from the face for plastering and lathing operations shall be 18 inches (46 cm): a. At the jobsite, the planking on the folding trestle type scaffolding was 25 inches from the face of the building where employees were applying plaster, exposing employees to a 5 foot fall hazard, on or about 2/3/16.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 C02 II
Issuance Date 2016-03-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-04-20
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: a. At the jobsite, wood boards and pieces of concrete were used to support the legs of the folding trestle type scaffolding employees were working from, exposing employees to a 5 foot fall hazard, on or about 2/3/16.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19260452 N01
Issuance Date 2016-03-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-04-20
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(n)(1): Scaffold platforms shall not be placed any higher than the second highest rung or step of the ladder supporting the platform: a. At the jobsite, planking on the folding trestle type scaffolding was placed on the top rung, exposing employees to a 6 foot fall hazard, on or about 2/3/16.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2016-03-21
Abatement Due Date 2016-03-31
Current Penalty 0.0
Initial Penalty 4200.0
Final Order 2016-04-20
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a. At the jobsite, untrained employees erected and moved tubular framed walkthrough scaffolding and folding trestle type scaffolding without the supervision of a competent person, exposing employees to fall hazards between 5 & 7 feet, on or about 2/3/16.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2016-03-21
Abatement Due Date 2016-03-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-04-20
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a. At the jobsite, employees working from scaffolding were not trained regarding the recognition of hazards associated with scaffolding and how to control those hazards, exposing the employees to a fall hazard between 5 and 7 feet, on or about 2/3/16.

Date of last update: 02 Apr 2025