Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-04-23
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2015-07-17
|
Related Activity
Type |
Inspection |
Activity Nr |
973928 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
974011 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
973941 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
973870 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2014-05-14 |
Abatement Due Date |
2014-06-10 |
Current Penalty |
0.0 |
Initial Penalty |
2800.0 |
Contest Date |
2014-06-10 |
Final Order |
2015-07-17 |
Nr Instances |
1 |
Nr Exposed |
30 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a. Training and education was not provided for the GC superintendent and assistant superintendent on safety requirements such as, but not limited to, scaffolding and scaffolding requirements, fall protection requirements, electrical safety and temporary power lighting requirements, and heavy machinery use and safety requirements such as back up alarms. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2014-05-14 |
Current Penalty |
3000.0 |
Initial Penalty |
2000.0 |
Contest Date |
2014-06-10 |
Final Order |
2015-07-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. At the yard area and inside the building, employees were exposed to overhead hazards, in that, head protection such as hard hats were not used while entering and exiting the building where overhead work was conducted at the exterior and at the interior of the building. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260405 A02 II C |
Issuance Date |
2014-05-14 |
Current Penalty |
2000.0 |
Initial Penalty |
1200.0 |
Contest Date |
2014-06-10 |
Final Order |
2015-07-17 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(a)(2)(ii)(C): Receptacles for uses other than temporary lighting were installed on branch circuits which supplied temporary lighting: a. Inside the building, employees were exposed to electrical hazards, in that, temporary lighting was plugged into a circuit supplying receptacles used with portable power tools. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260405 A02 II E |
Issuance Date |
2014-05-14 |
Current Penalty |
2000.0 |
Initial Penalty |
1200.0 |
Contest Date |
2014-06-10 |
Final Order |
2015-07-17 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage: a. Inside the building, employees were exposed to electrical hazards, in that, lamps for temporary lighting were not protected from accidental contact or breakage by being enclosed in a plastic or metal casing. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260451 B02 |
Issuance Date |
2014-05-14 |
Current Penalty |
0.0 |
Initial Penalty |
2800.0 |
Contest Date |
2014-06-10 |
Final Order |
2015-07-17 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a. At the perimeter of the building, a two frame tubular welded scaffold was used exposing employees of the stucco contractor to an 11 feet fall hazard, in that, the employees were standing on single plank platforms while reaching elevations at the exterior of the building. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19260452 C02 |
Issuance Date |
2014-05-14 |
Current Penalty |
0.0 |
Initial Penalty |
2800.0 |
Contest Date |
2014-06-10 |
Final Order |
2015-07-17 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: a. At the perimeter of the building, a two frame tubular welded scaffold was used exposing employees of the stucco contractor to a 14 feet fall hazard, in that, the scaffold did not have cross braces at the wall side. |
|
|