Search icon

ALLIED METALS, LLC - Florida Company Profile

Company Details

Entity Name: ALLIED METALS, LLC
Jurisdiction: FLORIDA
Filing Type: Foreign Limited Liability Co.
Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 18 Oct 2012 (12 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 19 Nov 2013 (11 years ago)
Document Number: M12000006258
FEI/EIN Number 461020676

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2902 NW 32ND AVE, MIAMI, FL, 33142
Mail Address: 2902 NW 32ND AVE, MIAMI, FL, 33142
ZIP code: 33142
County: Miami-Dade
Place of Formation: DELAWARE

Key Officers & Management

Name Role Address
CORPDIRECT AGENTS, INC. Agent -
SCHILBERG BERNARD C Chief Executive Officer 2902 NW 32ND AVE, MIAMI, FL, 33142
SCHILBERG NATHAN B Chief Financial Officer 2902 NW 32ND AVE, MIAMI, FL, 33142
MOSHEIM PAUL L President 2902 NW 32ND AVE, MIAMI, FL, 33142

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2015-03-26 CorpDirect Agents, Inc. -
REGISTERED AGENT ADDRESS CHANGED 2015-03-26 1200 SOUTH PINE ISLAND ROAD, PLANTATION, FL 33324 -
REINSTATEMENT 2013-11-19 - -
CHANGE OF PRINCIPAL ADDRESS 2013-11-19 2902 NW 32ND AVE, MIAMI, FL 33142 -
CHANGE OF MAILING ADDRESS 2013-11-19 2902 NW 32ND AVE, MIAMI, FL 33142 -
REVOKED FOR ANNUAL REPORT 2013-09-27 - -

Documents

Name Date
ANNUAL REPORT 2024-01-25
ANNUAL REPORT 2023-04-13
ANNUAL REPORT 2022-05-23
ANNUAL REPORT 2021-07-30
ANNUAL REPORT 2020-07-14
ANNUAL REPORT 2019-04-08
ANNUAL REPORT 2018-04-04
ANNUAL REPORT 2017-04-05
ANNUAL REPORT 2016-04-14
ANNUAL REPORT 2015-03-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340196294 0418800 2015-01-21 2902 NW 32ND AVE, MIAMI, FL, 33142
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2015-01-21
Emphasis N: LEAD, N: PMETALS
Case Closed 2015-07-07

Related Activity

Type Referral
Activity Nr 933025
Health Yes
Type Inspection
Activity Nr 1009754
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2015-05-19
Current Penalty 2160.0
Initial Penalty 3600.0
Final Order 2015-06-09
Nr Instances 1
Nr Exposed 37
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about January 21st 2015, at 2902 NW 32nd Ave. Miami FL, 33142, the employer did not develop or provide training for employees who are exposed to hazardous materials such as, but not limited to Lead, Cadmium, Copper, Zinc Oxide, Iron Oxide and LP gas being used for fork lift operations.
Citation ID 02001
Citaton Type Other
Standard Cited 19100095 I04
Issuance Date 2015-05-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-09
Nr Instances 1
Nr Exposed 37
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.95(i)(4): The employer did not provide training in the use and care of all hearing protectors provided to employees: On or about January 21st 2015, at 2902 NW 32nd Ave. Miami FL, 33142, the employer did not provide training in the use and care of the ear plugs that were provided to and used by the employees.
Citation ID 02002
Citaton Type Other
Standard Cited 19101025 D03 I
Issuance Date 2015-05-19
Abatement Due Date 2015-06-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-09
Nr Instances 3
Nr Exposed 37
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1025(d)(3)(i): The initial determination for lead was not based on employee exposure monitoring results and other relevant considerations listed in 29 CFR 1910.1025(d)(3)(i)(A), (B) and/or (C): On or about January 21st 2015, at the above addressed jobsite, the employer did not conduct sampling to determine the employees exposure to lead during the sorting of recycle metals at the facility.
Citation ID 02003
Citaton Type Other
Standard Cited 19101025 H01
Issuance Date 2015-05-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-09
Nr Instances 2
Nr Exposed 37
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead: On or about January 21st 2015, at the above addressed jobsite, it was determined that all surfaces were not maintained as free as practicable of lead accumulations in that lead dust was found on the lunch table.
340097542 0418800 2014-11-21 2902 NW 32ND AVE, MIAMI, FL, 33142
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2015-02-24
Emphasis N: AMPUTATE, N: SSTARG14, P: SSTARG14
Case Closed 2015-07-07

Related Activity

Type Referral
Activity Nr 933025
Health Yes
Type Inspection
Activity Nr 1019629
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100023 C01
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 3150.0
Initial Penalty 6300.0
Final Order 2015-06-09
Nr Instances 1
Nr Exposed 35
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. a.) On or about April 8, 2015, at the above addressed job site, employees were exposed to a fall hazard while working from a loading dock that was more than 4 feet that was not guarded.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100147 C04 II
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 3150.0
Initial Penalty 6300.0
Final Order 2015-06-09
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy. a.) On or about January 7, 2015, at the above addressed jobsite, the energy control procedures for the balers provided by the employer were not specific as they did not contain specific information specified in the standard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100147 C06 I
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 3150.0
Initial Penalty 6300.0
Final Order 2015-06-09
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a.) On or about January 7, 2015, at the above addressed jobsite, the employer did not conduct a periodic inspection at least annually to ensure that the energy control procedures and the requirements of this standard were being followed to secure two baling machines which were being maintained by employees who had not de energized and locked the electrical disconnect panel.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100147 D02
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 3150.0
Initial Penalty 6300.0
Final Order 2015-06-09
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment by the manufacturer: a.) On or about January 7, 2015, at the above addressed jobsite, the employer did not ensure that energy isolating devices such as electrical disconnects, locks and tags, were used in such a manner to isolate the electrical energy source on two baling machines that employees had maintained and had not de energized and locked the electrical disconnect panel.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100147 D04 I
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-09
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a.) On or about January 7, 2015, at the above addressed jobsite, the employer did not ensure that locks and tags were used by authorized employees to secure electrical power at disconnect panels on two baling machines that employees had been maintaining and had not de energized and locked the electrical disconnect panel before maintaining or clearing jams.
Citation ID 01004C
Citaton Type Serious
Standard Cited 19100147 D06
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-09
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished: a.) On or about January 7, 2015, at the above addressed jobsite, the employer did not ensure that authorized employees had verified that the electrical power had been isolated and de energized on two baling machines that employees had been maintaining and had not de energized and locked the electrical disconnect panel.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 2250.0
Initial Penalty 4500.0
Final Order 2015-06-09
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a.) On or about April 8, 2015, at the above addressed job site, employees were exposed to amputation hazards while operating the Canton Fdy & Massey Co. metal shear that lacked point of operation guard at the cutting blades.
Citation ID 01006
Citaton Type Serious
Standard Cited 19100215 A04
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 2250.0
Initial Penalty 4500.0
Final Order 2015-06-09
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) On or about January 7, 2015, at the above addressed jobsite, employees were exposed to struck by and cut by hazards while using a bench grinder whose work rests were in excess of one half inch from the grinding surface of the wheel.
Citation ID 01007
Citaton Type Serious
Standard Cited 19100215 B09
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 2250.0
Initial Penalty 4500.0
Final Order 2015-06-09
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel. a) On or about January 7, 2015, at the above addressed jobsite, employees were exposed to struck by and cut by hazards while using a bench grinder whose tongue guards were in excess of one half inch from the grinding surface of the wheel.
Citation ID 01008
Citaton Type Serious
Standard Cited 19100219 C04 I
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 2250.0
Initial Penalty 4500.0
Final Order 2015-06-09
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a.) On or about April 8, 2015, at the above addressed job site, employees were exposed to caught in between hazards while operating the Canton Fdy & Massey Co. metal shear that had an exposed rotating shaft on the drive motor.
Citation ID 01009
Citaton Type Serious
Standard Cited 19100219 F01
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 2250.0
Initial Penalty 4500.0
Final Order 2015-06-09
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii): a.) On or about April 8, 2015, at the above addressed job site, employees were exposed to caught-in between hazards while operating a the Canton Fdy & Massey Co. metal shear that had exposed spur gears that were not enclosed.
Citation ID 01010
Citaton Type Serious
Standard Cited 19100303 G02 I
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 3150.0
Initial Penalty 6300.0
Final Order 2015-06-09
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a.) On or about January 7, 2015, at the above addressed jobsite, employees were exposed to 440 VAC electrocution hazards while operating a disconnect switch inside the energized IPS baler control panel within close proximity to energized conductors.
Citation ID 02001
Citaton Type Other
Standard Cited 19100303 C03 I
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-09
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(c)(3)(i): All splices and joints and the free ends of the conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose. a.) On or about April 8, 2015, at the above addressed job site, employees were exposed to shock and electrocution while using the Dayton pedestal fan that had a spliced 110 VAC electrical power cord.
Citation ID 02002
Citaton Type Other
Standard Cited 19100305 B02 I
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-09
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a.) On or about April 8, 2015, at the above addressed job site, employees were exposed to shock and electrocution hazards while working in proximity to the IPS Baler which had a junction box that was energized with 110 VAC that lacked a cover.
Citation ID 02003
Citaton Type Other
Standard Cited 19100305 G02 III
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-09
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. a.) On or about April 8, 2015, at the above addressed job site, employees were exposed to shock and electrocution hazard while using the Canton Fdy & Massey Co. metal shear that had a 220 VAC flexible cord that had a plug that had damaged outer jacket insulation and lacked strain relief.

Date of last update: 03 Mar 2025