343904165
|
0418800
|
2019-03-28
|
2250 NW 77TH TERRACE, MIAMI, FL, 33147
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2019-03-28
|
Case Closed |
2023-03-16
|
Related Activity
Type |
Inspection |
Activity Nr |
1373981 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19101200 E01 |
Issuance Date |
2019-04-05 |
Abatement Due Date |
2019-04-24 |
Current Penalty |
212.0 |
Initial Penalty |
212.0 |
Final Order |
2019-05-03 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about March 28, 2018, at the above jobsite, 2250 NW 77th Terrace, Miami, Florida 33147, the employer did not develop or implement a written hazard communication program for the employees who are exposed to hazardous chemicals, including but not limited to, welding rods, acetylene, argon, and liquefied petroleum gas (LPG). The Remington Steel and Signs, LLC was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1910 1200(e), or its equivalent standard, which was contained in OSHA inspection number 1312590, citation number 01, item number 001, and was affirmed as a final order on 11/05/2018 with respect to a workplace located at 2250 NW 77th Terrace, Miami, Florida 33147. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100134 K |
Issuance Date |
2019-04-05 |
Abatement Due Date |
2019-04-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-05-03 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k): The employer did not provide training and the basic information in Appendix D of this section for employees provided respirators for voluntary use: On or about March 28, 2019, at the jobsite 2250 NW 77th Terrace, Miami Florida, 33147, employees who voluntarily wear a dust mask were not provided the information contained in Appendix D of CFR 29 1910.134. |
|
|
343739819
|
0418800
|
2019-01-25
|
2250 NW 77TH TERRACE, MIAMI, FL, 33147
|
|
Inspection Type |
FollowUp
|
Scope |
NoInspection
|
Safety/Health |
Health
|
Close Conference |
2019-01-25
|
Case Closed |
2019-05-17
|
Related Activity
Type |
Inspection |
Activity Nr |
1312590 |
Health |
Yes |
|
|
343159067
|
0418800
|
2018-05-10
|
2250 NW 77TH TERRACE, MIAMI, FL, 33147
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-08-15
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2023-03-16
|
Related Activity
Type |
Referral |
Activity Nr |
1334088 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100178 A04 |
Issuance Date |
2018-08-30 |
Abatement Due Date |
2018-09-19 |
Current Penalty |
1330.2 |
Initial Penalty |
2217.0 |
Final Order |
2018-09-18 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly: On or about 5/10/2018, at jobsite location 2250 NW 77th Terrace, Miami, FL 33147, a forklift with an attachment was not approved by the manufacturer and being used to move material at the yard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100253 B04 III |
Issuance Date |
2018-08-30 |
Abatement Due Date |
2018-09-19 |
Current Penalty |
2660.4 |
Initial Penalty |
4434.0 |
Final Order |
2018-09-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. On or about 5/10/2018, at jobsite location 2250 NW 77th Terrace, Miami, FL 33147, in the machine shop oxygen cylinders are being stored together with acetylene, and compress gas cylinders thereby exposing employees to a fire hazard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2018-08-30 |
Abatement Due Date |
2018-09-19 |
Current Penalty |
1330.2 |
Initial Penalty |
2217.0 |
Final Order |
2018-09-18 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about 5/10/2018, at jobsite location 2250 NW 77th Terrace, Miami, FL 33147, in the machine shop an electrical outlet box with open knockout rings, and exposed electrical cables was being used to connect hand tools, exposing the employee to an electrical shock hazard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100037 A03 |
Issuance Date |
2018-08-30 |
Abatement Due Date |
2018-09-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-09-18 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: On or about 5/10/2018, at jobsite location 2250 NW 77th Terrace, Miami, FL 33147, in the welding department employees were exposed to the obstructed hazard of being trapped in the event of a fire by steel trusses where the exit doors are located impeding egress in case of emergency. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100305 G01 IV B |
Issuance Date |
2018-08-30 |
Abatement Due Date |
2018-09-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-09-18 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors: On or about 5/10/2018, at jobsite location 2250 NW 77th Terrace, Miami, FL 33147, in the machine shop flexible cord were run throughout a wall hole to energize hand tools. |
|
|
343125902
|
0418800
|
2018-04-26
|
2250 NW 77TH TERRACE, MIAMI, FL, 33147
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2018-04-26
|
Emphasis |
L: FORKLIFT, L: HINOISE
|
Case Closed |
2023-03-16
|
Related Activity
Type |
Complaint |
Activity Nr |
1330967 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2018-10-24 |
Abatement Due Date |
2018-11-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-11-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): On or about April 26, 2018, at the jobsite location 2250 NW 77th Terrace Miami, Florida 33147, the employer did not develop or implement a written hazard communication program for employees who are exposed to hazardous chemicals, including but not limited to, welding rods, acetylene, argon and liquefied petroleum gas (LPG). |
|
|