Search icon

OVERHOLT ENTERPRISES, LLC - Florida Company Profile

Company Details

Entity Name: OVERHOLT ENTERPRISES, LLC
Jurisdiction: FLORIDA
Filing Type: Foreign Limited Liability Co.
Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 01 Dec 2011 (13 years ago)
Date of dissolution: 27 Sep 2019 (6 years ago)
Last Event: REVOKED FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2019 (6 years ago)
Document Number: M11000006017
FEI/EIN Number 263423872

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3506 STATE ROUTE 224, MONTEZUMA, GA, 31063
Mail Address: 3506 STATE ROUTE 224, MONTEZUMA, GA, 31063
Place of Formation: GEORGIA

Key Officers & Management

Name Role Address
C T CORPORATION SYSTEM Agent -
OVERHOLT HENRY Managing Member 3506 STATE ROUTE 224, MONTEZUMA, GA, 31063
OVERHOLT DAVID Managing Member 3506 STATE ROUTE 224, MONTEZUMA, GA, 31063
OVERHOLT JONATHON Managing Member 3506 STATE ROUTE 224, MONTEZUMA, GA, 31063

Events

Event Type Filed Date Value Description
REVOKED FOR ANNUAL REPORT 2019-09-27 - -

Documents

Name Date
ANNUAL REPORT 2018-03-08
ANNUAL REPORT 2017-02-09
ANNUAL REPORT 2016-03-28
ANNUAL REPORT 2015-03-02
ANNUAL REPORT 2014-01-29
ANNUAL REPORT 2013-01-28
ANNUAL REPORT 2012-04-24
Foreign Limited 2011-12-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339935355 0420600 2014-08-26 1221 SW EUCALYPTUS AVENUE, ARCADIA, FL, 34266
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2014-08-26
Emphasis L: FORKLIFT
Case Closed 2014-12-19

Related Activity

Type Complaint
Activity Nr 903798
Safety Yes
Health Yes
Type Inspection
Activity Nr 993553
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100023 C01
Issuance Date 2014-10-30
Abatement Due Date 2014-11-12
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2014-11-18
Nr Instances 6
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. a) For employees working at 1221 SW Eucalyptus Avenue in Arcadia, as observed on or about August 26, 2014. Employees were working off unguarded platforms that were greater than 4 feet in height above the ground level.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100133 A01
Issuance Date 2014-10-30
Abatement Due Date 2014-11-12
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2014-11-18
Nr Instances 3
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) For employees working at 1221 SW Eucalyptus Avenue in Arcadia, as observed on or about August 26, 2014. Employees were working with pneumatic nail guns without the use of appropriate eye protection. Employees were exposed to struck by hazard.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100213 C01
Issuance Date 2014-10-30
Abatement Due Date 2014-11-12
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2014-11-18
Nr Instances 1
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) For employees working at 1221 SW Eucalyptus Avenue in Arcadia, as observed on or about August 26, 2014. Employees were using a table saw that did not have the guard attached. Employees were exposed to an amputation hazard.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100213 C02
Issuance Date 2014-10-30
Abatement Due Date 2014-11-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-11-18
Nr Instances 1
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) For employees working at 1221 SW Eucalyptus Avenue in Arcadia, as observed on or about August 26, 2014. Employees were using a table saw to rip lumber that was not equipped with a spreader.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100242 B
Issuance Date 2014-10-30
Abatement Due Date 2014-12-26
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2014-11-18
Nr Instances 3
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) For employees working at 1221 SW Eucalyptus Avenue in Arcadia, as observed on or about August 26, 2014. Employees were using compressed air at a working pressure of approximately 128 p.s.i.; to clean dust and wood chips in the work areas.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100305 A02 IX
Issuance Date 2014-10-30
Abatement Due Date 2014-12-26
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2014-11-18
Nr Instances 4
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(a)(2)(ix): Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lamp holder with a guard: a) For employees working at 1221 SW Eucalyptus Avenue in Arcadia, as observed on or about August 26, 2014. Employees were working in the outside shed installing roofing materials with lamps utilized for general illumination that were not protected from accidental contact or breakage.
Citation ID 02001A
Citaton Type Other
Standard Cited 19100134 C02 I
Issuance Date 2014-10-30
Abatement Due Date 2014-12-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-11-18
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) For employees working at 1221 SW Eucalyptus Avenue in Arcadia, as observed on or about August 26, 2014. Employees were using employer supplied respirators for voluntary use to spray paint/sealant. Employees were not provided with the information contained in Appendix D in that the employees did not read and heed all instructions provided by the manufacturer and did not know what atmosphere the cartridge in use was manufactured to protect against.
Citation ID 02001B
Citaton Type Other
Standard Cited 19100134 C02 II
Issuance Date 2014-10-30
Abatement Due Date 2014-12-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-11-18
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) For employees working at 1221 SW Eucalyptus Avenue in Arcadia, as observed on or about August 26, 2014. Employees were using a respirator to spray sealant on the new sheds. Employer did not establish a written program that contained a medical certification of employees using the respirators and the proper storage of the respirator.