Search icon

ARCHER WESTERN CONSTRUCTION, LLC - Florida Company Profile

Branch

Company Details

Entity Name: ARCHER WESTERN CONSTRUCTION, LLC
Jurisdiction: FLORIDA
Filing Type: Foreign Limited Liability Co.
Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 24 May 2010 (15 years ago)
Branch of: ARCHER WESTERN CONSTRUCTION, LLC, ILLINOIS (Company Number LLC_02861852)
Document Number: M10000002359
FEI/EIN Number 270887868

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 929 WEST ADAMS STREET, CHICAGO, IL, 60607, US
Mail Address: 929 WEST ADAMS STREET, CHICAGO, IL, 60607, US
Place of Formation: ILLINOIS

Key Officers & Management

Name Role Address
PERSING MATT Manager 1315 EAST 7TH AVENUE, TAMPA, FL, 33615
Gerken Timothy S Treasurer 929 WEST ADAMS STREET, CHICAGO, IL, 60607
WALKER DAVID BUSI 929 WEST ADAMS STREET, CHICAGO, IL, 60607
CORPORATION SERVICE COMPANY Agent -

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G16000011780 AW/MCM JV EXPIRED 2016-02-01 2021-12-31 - 4501 NE 21 LANE, FORT LAUDERDALE, FL, 33308

Documents

Name Date
ANNUAL REPORT 2025-01-06
ANNUAL REPORT 2024-01-16
ANNUAL REPORT 2023-02-10
ANNUAL REPORT 2022-04-21
ANNUAL REPORT 2021-02-09
ANNUAL REPORT 2020-04-28
ANNUAL REPORT 2019-02-07
ANNUAL REPORT 2018-01-24
ANNUAL REPORT 2017-01-09
ANNUAL REPORT 2016-04-18

USAspending Awards. Contracts

Contract Type Award or IDV Flag PIID Start Date Current End Date Potential End Date
DEFINITIVE CONTRACT AWARD W9123623C2001 2023-04-19 2026-09-12 2026-09-12
Unique Award Key CONT_AWD_W9123623C2001_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 59800031.45
Current Award Amount 59800031.45
Potential Award Amount 59800031.45

Description

Title DEEP CREEK BRIDGE CONSTRUCTION PROJECT MODIFICATION P00002 PROGRESS PAYMENT AUTHORIZATION UNDER FAR 52.232-5 FOR STORED MATERIAL.
NAICS Code 237310: HIGHWAY, STREET, AND BRIDGE CONSTRUCTION
Product and Service Codes Y1LB: CONSTRUCTION OF HIGHWAYS, ROADS, STREETS, BRIDGES, AND RAILWAYS

Recipient Details

Recipient ARCHER WESTERN CONSTRUCTION LLC
UEI VN9DYLPXHA44
Recipient Address UNITED STATES, 4343 ANCHOR PLAZA PKWY STE 155, TAMPA, HILLSBOROUGH, FLORIDA, 336347532
DEFINITIVE CONTRACT AWARD W912EP12C0027 2012-09-24 2015-05-31 2015-05-31
Unique Award Key CONT_AWD_W912EP12C0027_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 28018607.32
Current Award Amount 28018607.32
Potential Award Amount 28618607.32

Description

Title HHD CULVERTS 4A AND 3
NAICS Code 237990: OTHER HEAVY AND CIVIL ENGINEERING CONSTRUCTION
Product and Service Codes Y1KA: CONSTRUCTION OF DAMS

Recipient Details

Recipient ARCHER WESTERN CONSTRUCTION LLC
UEI VN9DYLPXHA44
Legacy DUNS 078425214
Recipient Address 4343 ANCHOR PLAZA PKWY STE 155, TAMPA, HILLSBOROUGH, FLORIDA, 336347532, UNITED STATES

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
348022740 0420600 2025-02-05 1ST AVE AND TRAVELERS WAY N, SAINT PETERSBURG, FL, 33707
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2025-02-05
Emphasis N: TRENCH

Related Activity

Type Referral
Activity Nr 2258483
Safety Yes
345253819 0420600 2021-04-15 I-275 AND ROOSEVELT BLVD N IN THE MEDIAN, SAINT PETERSBURG, FL, 33701
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2021-04-15
Emphasis N: TRENCH
Case Closed 2021-05-12

Related Activity

Type Complaint
Activity Nr 1755985
Safety Yes
343566642 0419700 2018-10-30 11650 HOULE ROAD, JACKSONVILLE, FL, 32202
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-11-08
Case Closed 2018-11-27

Related Activity

Type Referral
Activity Nr 1395015
Safety Yes
343037156 0418800 2018-03-20 SB I-95 NW 62ND STREET, MIAMI, FL, 33142
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-03-23
Case Closed 2018-07-24

Related Activity

Type Referral
Activity Nr 1318736
Safety Yes
343016028 0419700 2018-03-14 1194 PALM AVENUE EXIT 348 I95 NORTH, JACKSONVILLE, FL, 32207
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2018-05-25
Case Closed 2018-06-07

Related Activity

Type Inspection
Activity Nr 1301555
Safety Yes
342930328 0418800 2018-02-05 I-95 AT NORTH OF 62ND STREET, MIAMI, FL, 33150
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2018-02-08
Emphasis N: TRENCH
Case Closed 2019-05-28

Related Activity

Type Accident
Activity Nr 1307216
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260021 B02
Issuance Date 2018-08-01
Abatement Due Date 2019-08-02
Current Penalty 3695.5
Initial Penalty 7391.0
Contest Date 2018-08-22
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: On or about February 4, 2018, on Interstate I-95 at North of 62nd Street in Miami, Florida, employees were exposed to struck-by and/or caught between hazards when performing trenching work prior to being provided with a training program that would enable them to recognize and avoid the hazards associated with trenching.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260651 I01
Issuance Date 2018-08-01
Abatement Due Date 2019-08-02
Current Penalty 12934.0
Initial Penalty 12934.0
Contest Date 2018-08-22
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(i)(1): Where the stability of adjoining buildings, walls, or other structures was endangered by excavation operations, support systems such as shoring, bracing or underpinning was not provided to ensure the stability of such structures for the protection of employees: On or about February 4, 2018, on Interstate I-95 at North of 62nd Street in Miami, Florida, employees were exposed to struck-by and/or caught between hazards when performing trench work adjacent to and below a concrete barrier wall that was not shored, braced and/or underpinned.
Citation ID 01003
Citaton Type Other
Standard Cited 19260651 K01
Issuance Date 2018-08-01
Abatement Due Date 2019-08-02
Current Penalty 12934.0
Initial Penalty 12934.0
Contest Date 2018-08-22
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift: On or about February 4, 2018, on Interstate I-95 at North of 62nd Street in Miami, Florida, employees were exposed to struck-by and/or caught between hazards when performing trenching work in a trench that was not inspected by a competent person prior to work commencing and as the work progressed for any hazards associated with the trench.
342464617 0419700 2017-07-13 1194 PALM AVE. THE OVERLAND HIGHWAY PROJECT, JACKSONVILLE, FL, 32207
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2017-11-03
Case Closed 2018-02-02

Related Activity

Type Referral
Activity Nr 1237775
Health Yes
342269347 0420600 2017-04-19 5512 AIRPORT SERVICE RD LOT C, TAMPA, FL, 33607
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2017-07-14
Emphasis L: FALL
Case Closed 2018-08-21

Related Activity

Type Referral
Activity Nr 1201441
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Other
Standard Cited 19260451 F07
Issuance Date 2017-07-19
Current Penalty 10267.2
Initial Penalty 11408.0
Final Order 2017-08-14
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration and such activities were not performed only by experienced and trained employees selected for such work by the competent person: On or about 04/12/2017, employees were exposed to a 30 foot fall hazard, in that, system scaffold side brackets were erected during progress of work without the supervision of a competent person trained on system scaffold (modular scaffold) safety and the work was performed by employees who were not trained on system scaffold side bracket erection.
Citation ID 01001B
Citaton Type Other
Standard Cited 19260454 A
Issuance Date 2017-07-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-14
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards as required by paragraph (a)(1)-(5) of this section: a. Inside the elevator shaft, employees used a system scaffold by moving scaffold brackets to the various working elevations. Employees were not provided training and education on scaffold use as follows: 1. The nature of fall hazards and any falling object hazards. 2. The correct procedures for dealing with erecting, maintaining, and disassembling the fall protection system and falling object protection system being used. 3. The proper use of the scaffold, and the proper handling of material on the scaffold. 4. The maximum intended load and load carrying capacities of the scaffold. 5. Any other pertinent requirements of Subpart "L" (Scaffolds) under 29 CFR 1926.
Citation ID 01001C
Citaton Type Other
Standard Cited 19260454 B
Issuance Date 2017-07-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-14
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: a. Inside the elevator shaft, employees erected a system scaffold by moving scaffold brackets to various working elevations. Employees were not provided training and education on scaffold erection as follows: 1. The nature of scaffold hazards; 2. The correct procedures for erecting, disassembling, moving, operating, repairing, inspecting, and maintaining the type of scaffold in question; 3. The design criteria, maximum intended load-carrying capacity and intended use of the scaffold; 4. Any other pertinent requirements of this subpart.
340979285 0419700 2015-10-09 FL/DOT I-95 BRIDGE REPLACEMENT S. HAMPTON & HENDRICKS AVE. BRIDGE #720153, JACKSONVILLE, FL, 32207
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-10-09
Emphasis N: CTARGET, L: FALL, P: CTARGET
Case Closed 2015-10-14
340691963 0419700 2015-06-02 1901 SERVICE STREET, JACKSONVILLE, FL, 32207
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2015-06-09
Case Closed 2015-06-12

Related Activity

Type Complaint
Activity Nr 988353
Safety Yes
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2015-03-11
Emphasis N: CTARGET, P: CTARGET
Case Closed 2015-10-13

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260102 A01
Issuance Date 2015-08-04
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-10-13
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: On or about March, 10, 2015, at the above addressed jobsite, the employer did not ensure employees used personal protective equipment such as, chemical goggles and face shields for employees who were exposed to hazardous chemicals, while handling Lambert Make Set during grout mixing operations.
Citation ID 02001
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2015-08-04
Abatement Due Date 2015-08-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-10-13
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): (Construction Reference: 1926.59)(a) On or about March, 10, 2015, at the above addressed jobsite, the employer did not develop and implement a written hazard communication program for employees who were exposed to hazardous chemicals, such as, but not limited to, Lambert Make Set when performing grout mixing operations.