Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2014-10-30 |
Abatement Due Date |
2014-12-26 |
Current Penalty |
1750.0 |
Initial Penalty |
3500.0 |
Final Order |
2014-11-13 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a) For employees working at 1221 SW Eucalyptus Avenue in Arcadia, as observed on or about August 26, 2014, and at times prior, the employer exposed employees to struck-by and crush hazards in that employees were allowed to operate the Hyster forklift without a seatbelt installed. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100023 C01 |
Issuance Date |
2014-10-30 |
Abatement Due Date |
2014-11-12 |
Current Penalty |
2450.0 |
Initial Penalty |
4900.0 |
Final Order |
2014-11-13 |
Nr Instances |
6 |
Nr Exposed |
7 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. a) For employees working at 1221 SW Eucalyptus Avenue in Arcadia, as observed on or about August 26, 2014. Employees were working off unguarded platforms that were greater than 4 feet in height above the ground level. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100133 A01 |
Issuance Date |
2014-10-30 |
Abatement Due Date |
2014-11-12 |
Current Penalty |
1750.0 |
Initial Penalty |
3500.0 |
Final Order |
2014-11-13 |
Nr Instances |
3 |
Nr Exposed |
7 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) For employees working at 1221 SW Eucalyptus Avenue in Arcadia, as observed on or about August 26, 2014. Employees were working with pneumatic nail guns without the use of appropriate eye protection. Employees were exposed to struck by hazard. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100213 C01 |
Issuance Date |
2014-10-30 |
Abatement Due Date |
2014-11-12 |
Current Penalty |
2450.0 |
Initial Penalty |
4900.0 |
Final Order |
2014-11-13 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) For employees working at 1221 SW Eucalyptus Avenue in Arcadia, as observed on or about August 26, 2014. Employees were using a table saw that did not have the guard attached. Employees were exposed to an amputation hazard. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100213 C02 |
Issuance Date |
2014-10-30 |
Abatement Due Date |
2014-11-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-11-13 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) For employees working at 1221 SW Eucalyptus Avenue in Arcadia, as observed on or about August 26, 2014. Employees were using a table saw to rip lumber that was not equipped with a spreader. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2014-10-30 |
Abatement Due Date |
2014-12-26 |
Current Penalty |
2450.0 |
Initial Penalty |
4900.0 |
Final Order |
2014-11-13 |
Nr Instances |
3 |
Nr Exposed |
7 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) For employees working at 1221 SW Eucalyptus Avenue in Arcadia, as observed on or about August 26, 2014. Employees were using compressed air at a working pressure of approximately 128 p.s.i.; to clean dust and wood chips in the work areas. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100305 A02 IX |
Issuance Date |
2014-10-30 |
Abatement Due Date |
2014-12-26 |
Current Penalty |
1400.0 |
Initial Penalty |
2800.0 |
Final Order |
2014-11-13 |
Nr Instances |
4 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(a)(2)(ix): Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lamp holder with a guard: a) For employees working at 1221 SW Eucalyptus Avenue in Arcadia, as observed on or about August 26, 2014. Employees were working in the outside shed installing roofing materials with lamps utilized for general illumination that were not protected from accidental contact or breakage. |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19100134 C02 I |
Issuance Date |
2014-10-30 |
Abatement Due Date |
2014-12-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-11-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) For employees working at 1221 SW Eucalyptus Avenue in Arcadia, as observed on or about August 26, 2014. Employees were using employer supplied respirators for voluntary use to spray paint/sealant. Employees were not provided with the information contained in Appendix D in that the employees did not read and heed all instructions provided by the manufacturer and did not know what atmosphere the cartridge in use was manufactured to protect against. |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19100134 C02 II |
Issuance Date |
2014-10-30 |
Abatement Due Date |
2014-12-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-11-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) For employees working at 1221 SW Eucalyptus Avenue in Arcadia, as observed on or about August 26, 2014. Employees were using a respirator to spray sealant on the new sheds. Employer did not establish a written program that contained a medical certification of employees using the respirators and the proper storage of the respirator. |
|