Search icon

STEEL FABRICATORS, L.L.C. - Florida Company Profile

Company Details

Entity Name: STEEL FABRICATORS, L.L.C.
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

STEEL FABRICATORS, L.L.C. is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 07 Oct 1998 (26 years ago)
Last Event: CORPORATE MERGER
Event Date Filed: 29 Nov 2017 (7 years ago)
Document Number: L98000002174
FEI/EIN Number 650867570

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 721 N.E. 44TH STREET, FORT LAUDERDALE, FL, 33334-3150
Mail Address: 721 N.E. 44TH STREET, FORT LAUDERDALE, FL, 33334-3150
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
KURT LANGSENKAMP Vice President 721 NE 44TH STREET, FT. LAUDERDALE, FL, 33334
BURNS TIMOTHY Vice President 721 NE 44TH STREET, FT. LAUDERDALE, FL, 33334
BURNS TIMOTHY President 721 NE 44TH STREET, FT. LAUDERDALE, FL, 33334
BURNS TIMOTHY Secretary 721 NE 44TH STREET, FT. LAUDERDALE, FL, 33334
BURNS TIMOTHY Treasurer 721 NE 44TH STREET, FT. LAUDERDALE, FL, 33334
MCKEE AARON Vice President 721 NE 44TH STREET, FT. LAUDERDALE, FL, 33334
TURNER MAX President 721 N.E. 44TH STREET, FORT LAUDERDALE, FL, 333343150
Russell Shane Vice President 721 N.E. 44TH STREET, FORT LAUDERDALE, FL, 333343150
CORPORATE CREATIONS NETWORK INC. Agent -

Events

Event Type Filed Date Value Description
REGISTERED AGENT ADDRESS CHANGED 2020-03-25 801 US HIGHWAY 1, NORTH PALM BEACH, FL 33408 -
MERGER 2017-11-29 - CORPORATION WAS A MERGER RESULT. TOTAL NUMBER OF QUALIFIED CORPORATION(S) INVOLVED WAS 1. MERGER NUMBER 700000176217
REGISTERED AGENT NAME CHANGED 2006-09-21 CORPORATE CREATIONS NETWORK INC. -
AMENDED AND RESTATEDARTICLES 2000-12-04 - -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J24000573285 TERMINATED 1000001009675 BROWARD 2024-08-28 2044-09-04 $ 11,599.11 STATE OF FLORIDA, DEPARTMENT OF REVENUE, CORAL SPRINGS SERVICE CENTER, 3301 N UNIVERSITY DR STE 200, CORAL SPRINGS FL330654149
J12001024358 TERMINATED 1000000302164 BROWARD 2012-12-13 2022-12-19 $ 461.07 STATE OF FLORIDA, DEPARTMENT OF REVENUE, CORAL SPRINGS SERVICE CENTER, 3301 N UNIVERSITY DR STE 200, CORAL SPRINGS FL330654149

Documents

Name Date
ANNUAL REPORT 2024-02-12
ANNUAL REPORT 2023-03-27
ANNUAL REPORT 2022-03-28
ANNUAL REPORT 2021-03-24
ANNUAL REPORT 2020-03-25
ANNUAL REPORT 2019-04-01
AMENDED ANNUAL REPORT 2018-07-20
ANNUAL REPORT 2018-01-30
Merger 2017-11-29
ANNUAL REPORT 2017-03-30

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345630057 0418800 2021-11-08 721 NE 44TH STREET, OAKLAND PARK, FL, 33334
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2021-11-08
Case Closed 2021-11-10

Related Activity

Type Inspection
Activity Nr 1514604
Safety Yes
345146047 0418800 2021-02-11 721 NE 44TH STREET, OAKLAND PARK, FL, 33334
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2021-02-11
Case Closed 2021-10-04

Related Activity

Type Accident
Activity Nr 1733196

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2021-08-10
Abatement Due Date 2021-08-27
Current Penalty 13653.0
Initial Penalty 13653.0
Final Order 2021-09-01
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line OSH Act of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that, employees were exposed to struck-by and crushing hazards: On or about February 11, 2021, in the north bay of a facility located at 721 NE 44th Street in Fort Lauderdale, Florida, employees were exposed to struck-by and crushing hazards when hoisting a steel beam stored adjacent to other beams where they could make contact with each other.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100184 C09
Issuance Date 2021-08-10
Abatement Due Date 2021-08-27
Current Penalty 0.0
Initial Penalty 12288.0
Final Order 2021-09-01
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.184(c)(9):Employee(s) were not kept clear of load(s) suspended, or about to be lifted by sling(s): On or about February 11, 2021, in the north bay of a facility located at 721 NE 44th Street in Fort Lauderdale, Florida, an employee was exposed to a struck-by and crushing hazard when standing adjacent to steel I-beams being hoisted and moved.
Citation ID 02001
Citaton Type Other
Standard Cited 19100184 E01
Issuance Date 2021-08-10
Abatement Due Date 2021-08-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-09-01
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.184(e)(1):Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: On or about February 11, 2021, in the north bay of a facility located at 721 NE 44th Street in Fort Lauderdale, Florida, employees were using a steel chain sling that did not have a permanently affixed durable identification tag.
343737797 0418800 2019-01-18 550 S. ANDREWS AVE., FORT LAUDERDALE, FL, 33301
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2019-01-18
Emphasis L: FALL
Case Closed 2019-07-16

Related Activity

Type Complaint
Activity Nr 1418181
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2019-05-17
Abatement Due Date 2019-07-03
Current Penalty 4433.0
Initial Penalty 6819.0
Final Order 2019-06-18
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 18 March, 2019, on the 4th floor of a building under new construction, inside the elevator shaft two employees accessed a platform on a shoring scaffold was not fully planked, exposing the employee to a fall hazard of approximately 11 feet 4 inches.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2019-05-17
Abatement Due Date 2019-05-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-06-18
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. On or about 18 March, 2019, on the 4th floor of a building under new construction, inside the elevator shaft employees accessed a shoring scaffold without being trained to recognize the hazards associated with the type of scaffold being used, exposing the employee to a fall hazard of approximately 11 feet 4 inches.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B05 I
Issuance Date 2019-05-17
Abatement Due Date 2019-07-03
Current Penalty 4433.0
Initial Penalty 6819.0
Final Order 2019-06-18
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length extended over its support more than 12 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end: On or about 18 March, 2019, on the 4th floor of a building under new construction, inside the elevator shaft an employee accessed a platform on a shoring scaffold that extended over the support system and was not designed to be installed as such, exposing the employee to a fall hazard of approximately 11 feet 4 inches.
Citation ID 01003A
Citaton Type Other
Standard Cited 19260451 E01
Issuance Date 2019-05-17
Abatement Due Date 2019-07-03
Current Penalty 4433.0
Initial Penalty 6819.0
Final Order 2019-06-18
Nr Instances 2
Nr Exposed 3
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: On or about 18 March, 2019, on the 4th floor of a building under new construction, inside the elevator shaft employees accessed a shoring scaffold by climbing the side rails which were separated more than 14 inches each, exposing the employee to a fall hazard of approximately 11 feet 4 inches.
Citation ID 01003B
Citaton Type Other
Standard Cited 19260451 F03
Issuance Date 2019-05-17
Abatement Due Date 2019-07-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-06-18
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about 18 March, 2019, on the 4th floor of a building under new construction, inside the elevator shaft employees accessed a shoring scaffold without the scaffold being inspected by a competent person, exposing the employee to a fall hazard of approximately 11 feet 4 inches.
308412485 0418800 2005-10-07 1150 NW 14TH ST, MIAMI, FL, 33136
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2005-10-11
Case Closed 2006-04-19

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260350 F03
Issuance Date 2006-01-24
Abatement Due Date 2006-01-27
Current Penalty 394.0
Initial Penalty 525.0
Nr Instances 1
Nr Exposed 2
Gravity 05
Citation ID 01002
Citaton Type Serious
Standard Cited 19260350 H
Issuance Date 2006-01-24
Abatement Due Date 2006-01-27
Current Penalty 394.0
Initial Penalty 525.0
Nr Instances 1
Nr Exposed 2
Gravity 05
Citation ID 01003
Citaton Type Serious
Standard Cited 19260350 J
Issuance Date 2006-01-24
Abatement Due Date 2006-01-27
Current Penalty 393.0
Initial Penalty 525.0
Nr Instances 1
Nr Exposed 2
Gravity 05
301884995 0418800 1999-05-11 851 EAST COMMERCIAL BOULEVARD, OAKLAND PARK, FL, 33334
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 1999-05-12
Emphasis S: CONSTRUCTION
Case Closed 1999-07-13

Date of last update: 02 Mar 2025