347510794
|
0419700
|
2024-05-29
|
4522 ST. AUGUSTINE ROAD, JACKSONVILLE, FL, 32207
|
|
Inspection Type |
Planned
|
Scope |
NoInspection
|
Safety/Health |
Health
|
Close Conference |
2024-05-29
|
Emphasis |
L: HINOISE, P: HINOISE
|
Case Closed |
2024-05-30
|
|
347377509
|
0419700
|
2024-03-28
|
4522 ST. AUGUSTINE ROAD, JACKSONVILLE, FL, 32207
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-03-28
|
Emphasis |
P: AMPUTATE, N: AMPUTATE
|
Case Closed |
2024-05-29
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100212 A05 |
Issuance Date |
2024-05-01 |
Abatement Due Date |
2024-05-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-05-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(5): Exposure of blades. When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the blades shall be guarded. The guard shall have openings no larger than one-half (1/2) inch. a. In the shop building: On or about March 28, 2024, the employer exposed employees to an amputation and laceration hazard, in that the ventilation fan above the storage shelf was not guarded. |
|
|
347044810
|
0419700
|
2023-10-18
|
4733 ASTRAL STREET, JACKSONVILLE, FL, 32205
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2023-10-18
|
Emphasis |
N: FALL, P: FALL
|
Case Closed |
2024-05-07
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2024-02-27 |
Current Penalty |
3167.5 |
Initial Penalty |
4525.0 |
Final Order |
2024-04-10 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: a. At a worksite located at 4733 Astral Street, Jacksonville, FL 32205: On or about October 18, 2023, the employer exposed seven employees to eye injury hazards, in that eye protection was not utilized by employees who were operating pneumatic nail guns to nail down roof shingles. |
|
Citation ID |
02001 |
Citaton Type |
Serious |
Standard Cited |
19260503 C03 |
Issuance Date |
2024-02-27 |
Current Penalty |
17389.4 |
Initial Penalty |
24842.0 |
Final Order |
2024-04-10 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(c)(3): The employer did not retrain affected employees who already had been trained but demonstrated inadequate understanding and skill required by paragraph (a) of this section: a. On a residential roof located at 4733 Astral Street in Jacksonville Florida 32205: On or about October 18, 2023, the employer exposed seven employees to fall hazards in that guardrail systems, safety net systems, personal fall arrest systems or a combination therein was not utilized while seven employees were installing roofing shingles. Voss Incorporated dba Jack C. Wilson Roofing was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1642341, citation number 01, item number 001 and was affirmed as a final order on February 6, 2023 , with respect to a workplace located at 3985 Ferrara Street, Jacksonville, FL 32217. |
|
|
346423411
|
0419700
|
2023-01-09
|
3985 FERRARRA STREET, JACKSONVILLE, FL, 32217
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-01-09
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2023-05-31
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2023-01-27 |
Current Penalty |
5625.6 |
Initial Penalty |
9376.0 |
Final Order |
2023-02-06 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On a low-pitched residential roof located at 3985 Ferrara Street in Jacksonville Florida: On or about January 9, 2023, the employer exposed employees to fall hazards in that guardrail systems, safety net systems, personal fall arrest systems or a combination therein was not utilized while six employees were removing the shingles on a residential low sloped roof. |
|
|
345727036
|
0419700
|
2022-01-13
|
4522 ST. AUGUSTINE ROAD, JACKSONVILLE, FL, 32207
|
|
Inspection Type |
Planned
|
Scope |
NoInspection
|
Safety/Health |
Health
|
Close Conference |
2022-01-13
|
Emphasis |
L: HINOISE, P: HINOISE
|
Case Closed |
2022-02-04
|
|
341803617
|
0419700
|
2016-09-28
|
753 NOTTINGHAM FOREST COURT, FRUIT COVE, FL, 32259
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2016-11-16
|
Emphasis |
L: FALL
|
Case Closed |
2017-02-16
|
Related Activity
Type |
Referral |
Activity Nr |
1140569 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260502 D17 |
Issuance Date |
2016-12-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-01-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head: a) On or about September 28, 2016 an employee was installing roofing material on a one story single family house at a height of approximately 8-feet 7-Inches to ground, was using a harness with life line and lanyard for fall protection and his lanyard was connected to the front of the harness instead of connecting to the attachment point located on the back of the body harness. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19261053 B05 I |
Issuance Date |
2016-12-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-01-13 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support). a. On or about September 27, 2016, employees were using a Werner extension ladder that was not adequately installed to access the roof, exposing employees to a fall hazard. b. On or about September 28, 2016 employees were using a Werner extension ladder that was not adequately installed to access the roof, exposing employees to a fall hazard. |
|
|
339062408
|
0419700
|
2013-05-10
|
9839 TIMBERLAKE DRIVE E., JACKSONVILLE, FL, 32257
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-05-10
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2014-03-25
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2013-05-23 |
Abatement Due Date |
2013-05-23 |
Current Penalty |
1440.0 |
Initial Penalty |
2400.0 |
Final Order |
2013-06-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a. On or about May 10, 2013, an employee working below employees on the roof was not wearing a hard hat, exposing himself to the hazard of being struck in the head by falling objects. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B08 |
Issuance Date |
2013-05-23 |
Abatement Due Date |
2013-05-23 |
Current Penalty |
1440.0 |
Initial Penalty |
2400.0 |
Final Order |
2013-06-04 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder: a. On or about May 10, 2013, the portable extension ladder used by employees to access the roof was not secured to prevent accidental displacement, exposing employees to an 8-foot 3-inch fall hazard. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260102 A01 |
Issuance Date |
2013-05-23 |
Abatement Due Date |
2013-05-23 |
Current Penalty |
1920.0 |
Initial Penalty |
3200.0 |
Final Order |
2013-06-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
Voss Incorporated dba: Jack C. Wilson Roofing was previously cited for a violation of this Occupational Safety and Health Standard, or its equivalent standard, 29 CFR 1926.102(a)(1), which was contained in OSHA Inspection number 315485219, Citation number 01, Item number 001, issued on March 16, 2012, with respect to a workplace at 8710 Winchester Drive, Jacksonville, Florida 32271. The final order for this citation was April 9, 2012. 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about May 10, 2013, two employees were using pneumatic nail guns without the use of eye protection, exposing themselves to an eye injury. |
|
Citation ID |
02002 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2013-05-23 |
Abatement Due Date |
2013-05-23 |
Current Penalty |
2880.0 |
Initial Penalty |
4800.0 |
Final Order |
2013-06-04 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
Voss Incorporated dba: Jack C. Wilson Roofing was previously cited for a violation of this Occupational Safety and Health Standard, or its equivalent standard, 29 CFR 1926.501(b)(13), which was contained in OSHA Inspection number 315485219, Citation number 01, Item number 002, issued on March 16, 2012, with respect to a workplace at 8710 Winchester Drive, Jacksonville, Florida 32271. The final order for this citation was April 9, 2012. 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision of paragraph (b) of this section: a. On or about May 10, 2013, on a 4:12 pitch roof, employees performing roofing work were not protected from an 8-foot 3-inch fall hazard by the use of a fall protection system. |
|
|