Search icon

AZTEC EMPIRE LLC - Florida Company Profile

Company Details

Entity Name: AZTEC EMPIRE LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Company

AZTEC EMPIRE LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 08 Jan 2025 (3 months ago)
Document Number: L25000016164
FEI/EIN Number 88-2326332

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2120 W ORIENT ST, TAMPA, FL 33607
Mail Address: 2120 W ORIENT ST, TAMPA, FL 33607
ZIP code: 33607
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
AVILA, RODOLFO Agent 2120 W ORIENT ST, TAMPA, FL 33607
AVILA, RODOLFO Authorized Member 2120 W ORIENT ST, TAMPA, FL 33607 UN

Documents

Name Date
Florida Limited Liability 2025-01-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347413502 0420600 2024-04-15 2212 OASIS PALM CIRCLE BUILDING #4, CAPE CORAL, FL, 33991
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2024-04-15
Emphasis N: FALL

Related Activity

Type Inspection
Activity Nr 1741827
Safety Yes
Type Referral
Activity Nr 2151639
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 A02
Issuance Date 2024-04-29
Abatement Due Date 2024-05-23
Current Penalty 4258.8
Initial Penalty 7098.0
Final Order 2024-05-22
Nr Instances 3
Nr Exposed 13
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(a)(2): The employer did not determine if the walking/working surfaces on which its employees were to work on, had the strength and structure integrity to support employees safely: a. On or about April 15, 2024, at 2212 Oasis Palm Circle, Building #4, Cape Coral, Florida, 33991, employees were walking up and down four flights of job made stairs, wherein the stairs were constructed onsite without the use of engineering data/architectural drawings, during which time the third floor and second floor stairs collapsed; therefore exposing the employees to a fall hazards. b. On or about April 15, 2024, at 2212 Oasis Palm Circle, Building #5, Cape Coral, Florida, 33991, employees were walking up and down four flights of job made stairs, wherein the stairs were constructed onsite without the use of engineering data/architectural drawings; therefore exposing the employees to a fall hazards. c. On or about April 15, 2024, at 2212 Oasis Palm Circle, Building #6, Cape Coral, Florida, 33991, employees were walking up and down four flights of job made stairs, wherein the stairs were constructed onsite without the use of engineering data/architectural drawings; therefore exposing the employees to a fall hazards.
347118770 0419700 2023-11-21 12175 PHILIPS HIGHWAY, JACKSONVILLE, FL, 32256
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2023-11-21
Emphasis N: CTARGET, P: CTARGET
Case Closed 2024-11-21

Related Activity

Type Inspection
Activity Nr 1711871
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2024-03-19
Current Penalty 2766.0
Initial Penalty 4610.0
Final Order 2024-04-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: 1. Located at 12175 Philips Highway Jacksonville, Florida, 32256. On or about November 21, 2023, and at times prior, the employer did not ensure that eye protective equipment was being used when employees were exposed to struck by injuries while using battery powered nail guns.
346262108 0420600 2022-10-05 801 MAIN ST, DUNEDIN, FL, 34697
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2022-10-05
Emphasis L: FALL
Case Closed 2024-10-10

Related Activity

Type Complaint
Activity Nr 1953797
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2022-12-16
Current Penalty 2900.5
Initial Penalty 5801.0
Final Order 2023-01-13
Nr Instances 2
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1):Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) At the site, on or about 10/5/2022, the employer exposed employees to fall hazards of approximately 10 ft, in that guardrails on the second and third floor were taken down and not put back up while employees were working in the area.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2022-12-16
Current Penalty 2900.5
Initial Penalty 5801.0
Final Order 2023-01-13
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) At the site, on or about 10/5/2022, the employer exposed employees to fall hazards of approximately 32 ft, in that employees were performing decking work on roofs with no fall protection.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2022-12-16
Current Penalty 2486.0
Initial Penalty 4972.0
Final Order 2023-01-13
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1):Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. (a) At the site, on or about 10/5/2022, the employer exposed employees to fall hazards, in that the ladder used to access the roof did not extend at least 3 ft over the leading edge and no grasping device was provided to assist employees in dismounting.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2022-12-16
Current Penalty 2486.0
Initial Penalty 4972.0
Final Order 2023-01-13
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13):The top or top step of a stepladder was used as a step: (a) At the site, on or about 10/5/2022, the employer exposed employees to fall hazards, the top step of an A-frame ladder was used as a step to access the roof of Building B.

Date of last update: 07 Feb 2025

Sources: Florida Department of State