Search icon

MILLS & NEBRASKA, LLC - Florida Company Profile

Company Details

Entity Name: MILLS & NEBRASKA, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

MILLS & NEBRASKA, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 12 Dec 2024 (4 months ago)
Last Event: CONVERSION
Event Date Filed: 12 Dec 2024 (4 months ago)
Document Number: L24000527304
FEI/EIN Number 590189030

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2721 REGENT AVENUE, ORLANDO, FL, 32804, US
Mail Address: P.O. BOX 547757, ORLANDO, FL, 32854-7757, US
ZIP code: 32804
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
PULSIFER BRIDGET A Manager 2721 REGENT AVENUE, ORLANDO, FL, 32804
PULSIFER BRIDGET A Agent 2721 REGENT AVENUE, ORLANDO, FL, 32804

Events

Event Type Filed Date Value Description
CONVERSION 2024-12-12 - CORPORATION WAS A CONVERSION RESULT. CONVERTING CORPORATION WAS 127770. CONVERSION NUMBER 700000262517

Documents

Name Date
Florida Limited Liability 2024-12-12

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340930742 0420600 2015-09-16 2721 REGENT STREET, ORLANDO, FL, 32804
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2015-09-16
Emphasis L: FORKLIFT, N: AMPUTATE
Case Closed 2017-02-13

Related Activity

Type Inspection
Activity Nr 1012529
Safety Yes
340125293 0420600 2014-12-09 2721 REGENT STREET, ORLANDO, FL, 32804
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-12-09
Emphasis L: FORKLIFT, N: AMPUTATE, P: AMPUTATE
Case Closed 2017-02-13

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2015-01-29
Abatement Due Date 2015-02-18
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2015-02-24
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. In the metal framing shop, employees were exposed to an amputation hazard, in that, while cutting metal parts the guard on the Dayton bandsaw model # 3Z981 was not adjusted to the metal door frame parts leaving the blade exposed, on or about 12/09/2014. b. In the metal framing shop, employees were exposed to amputation and struck by hazards, in that, the Rockwell drill press did not have a cup guard, on or about 12/09/2014.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 B
Issuance Date 2015-01-29
Abatement Due Date 2015-02-25
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2015-02-24
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a. In the metal fabrication shop, employees were exposed to a struck by hazard, in that, that the Rockwell drill press was not anchored to the floor to prevent moving or walking while in use, on or about 12/09/2014.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100213 C01
Issuance Date 2015-01-29
Abatement Due Date 2015-02-18
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2015-02-24
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a. In the wood shop, employees were exposed to an amputation hazard in that the table saw did not have a an automatically adjusted hood while cutting molding and conducting other wood working activities, on or about 12/09/2014.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100213 B03
Issuance Date 2015-01-29
Abatement Due Date 2015-02-25
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2015-02-24
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure: a. In the metal framing shop, employees were exposed to an amputation hazard, in that, the the Dayton band saw model # 3Z981 would resume operation automatically when the power was restored, on or about 12/09/2014.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100213 H01
Issuance Date 2015-01-29
Abatement Due Date 2015-02-18
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2015-02-24
Nr Instances 2
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material. a. In the wood shop, employees were exposed to an amputation hazard, in that, on the Black and Decker Professional radial saw guard was blocked open during wood cutting operations, on or about 12/09/2014.
Citation ID 01006
Citaton Type Serious
Standard Cited 19100305 G02 III
Issuance Date 2015-01-29
Abatement Due Date 2015-02-18
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2015-02-24
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a. In the wood shop, employees were exposed to a contact hazard, in that, insulating wires of the table saw were exposed. There was no strain relief to prevent pull away, on or about bout 12/09/2014.
316028745 0420600 2011-09-16 3204-#4 WINTER LAKE ROAD, LAKELAND, FL, 33803
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2011-09-16
Case Closed 2011-09-23

Related Activity

Type Inspection
Activity Nr 315763169
315763169 0420600 2011-06-24 3204-#4 WINTER LAKE ROAD, LAKELAND, FL, 33803
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2011-06-24
Emphasis L: FORKLIFT, S: POWERED IND VEHICLE
Case Closed 2011-11-21

Related Activity

Type Complaint
Activity Nr 208415711
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100178 L01 I
Issuance Date 2011-07-11
Abatement Due Date 2011-07-29
Current Penalty 1800.0
Initial Penalty 1800.0
Nr Instances 3
Nr Exposed 3
Gravity 01
Citation ID 01002
Citaton Type Serious
Standard Cited 19100252 B02 III
Issuance Date 2011-07-11
Abatement Due Date 2011-07-24
Current Penalty 1800.0
Initial Penalty 1800.0
Nr Instances 1
Nr Exposed 3
Gravity 01

Date of last update: 02 Apr 2025

Sources: Florida Department of State