Entity Name: | DAVID PACHECO LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
DAVID PACHECO LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 13 Jun 2024 (10 months ago) |
Document Number: | L24000269817 |
Address: | 7300 N 174 TH TERRACE, HIALEAH, FL, 33015 |
Mail Address: | 7300 N 174 TH TERRACE, HIALEAH, FL, 33015 |
ZIP code: | 33015 |
County: | Miami-Dade |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
PACHECO DAVID | Manager | 7300 N 174 TH TERRACE, HIALEAH, FL, 33015 |
PACHECO DAVID | Agent | 7300 N 174 TH TERRACE, HIALEAH, FL, 33015 |
Name | Date |
---|---|
Florida Limited Liability | 2024-06-13 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347897811 | 0418600 | 2024-11-22 | 5356 ADELINE CIRCLE LOT 12A SENTINEL RIDGE, PACE, FL, 32571 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1776181 |
Safety | Yes |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2024-10-23 |
Emphasis | N: FALL, P: FALL |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2024-10-31 |
Current Penalty | 2765.0 |
Initial Penalty | 2765.0 |
Final Order | 2024-12-26 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles: a) At 5345 Adeline Court, Lot 11C Sentinel Ridge, Pace, Florida: On October 23, 2024; the employer allowed his employees to operate pneumatic nail guns without using eye protection while performing framing activities exposing his employees to struck-by hazards. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2024-10-31 |
Current Penalty | 2765.0 |
Initial Penalty | 2765.0 |
Final Order | 2024-12-26 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At 5345 Adeline Court, Lot 11C Sentinel Ridge, Pace, Florida: On October 23, 2024; the employer allowed his employees to perform framing activities without using fall protection exposing his employees to a fall hazard of 10 feet 10 inches to the ground below. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2024-09-18 |
Emphasis | N: FALL, P: FALL |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2024-09-30 |
Current Penalty | 3687.0 |
Initial Penalty | 3687.0 |
Final Order | 2024-11-18 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles: a) At 2989 Trestle Way, Iron Rock Lot 5C, Cantonment, Florida: On September 18, 2024; the employer allowed his employee to operate pneumatic nail guns without eye protection while performing framing activities exposing his employees to struck-by hazards. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2024-09-30 |
Abatement Due Date | 2024-10-15 |
Current Penalty | 6452.0 |
Initial Penalty | 6452.0 |
Final Order | 2024-11-18 |
Nr Instances | 2 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) At 2989 Trestle Way, Iron Rock Lot 5C, Cantonment, Florida: On September 18, 2024; the employer allowed his employee to perform framing activities without fall protection exposing his employee to a fall hazard of up to 19 feet 1 inch to the ground below. b) At 2983 Trestle Way, Iron Rock Lot 4C, Cantonment, Florida: On September 18, 2024; the employer allowed his employee to perform framing activities without fall protection exposing his employee to a fall hazard of 11 feet 6 inches to the ground below. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2024-09-30 |
Current Penalty | 3687.0 |
Initial Penalty | 3687.0 |
Final Order | 2024-11-18 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) At 2983 Trestle Way, Iron Rock Lot 4C, Cantonment, Florida: On September18, 2024; the employer allowed his employee to use an extension ladder to gain access to the roof and the rails of the ladder did not extend three feet above the roof landing to provide safe access exposing his employee to a fall hazard of 11 feet 6 inches to the ground below. |
Date of last update: 02 Apr 2025
Sources: Florida Department of State