Entity Name: | DIAZ CONSTRUCTION SERVICES LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
DIAZ CONSTRUCTION SERVICES LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 22 Jan 2024 (a year ago) |
Document Number: | L24000041539 |
Address: | 11740 SW 222 ST, MIAMI, FL, 33170, US |
Mail Address: | 11740 SW 222 ST, MIAMI, FL, 33170, US |
ZIP code: | 33170 |
County: | Miami-Dade |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
DIAZ BARRIOS GILBERTO | Manager | 11740 SW 222 ST, MIAMI, FL, 33170 |
DIAZ BARRIOS GILBERTO | Agent | 11740 SW 222 ST, MIAMI, FL, 33170 |
Name | Date |
---|---|
ANNUAL REPORT | 2025-01-22 |
Florida Limited Liability | 2024-01-22 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343648465 | 0419700 | 2018-12-07 | 1300 COUNTY ROAD 210, SAINT JOHNS, FL, 32259 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1364825 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1364743 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1364860 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2019-02-08 |
Current Penalty | 2557.5 |
Initial Penalty | 3410.0 |
Final Order | 2019-02-28 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about December 7, 2018: Two employees were observed installing the top plate while walking on the framing and were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employees provided with an alternative fall protection; exposing employees to a 9-feet fall hazard. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260020 B01 |
Issuance Date | 2019-02-08 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-02-28 |
Nr Instances | 1 |
Nr Exposed | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part. a) On or about December 7, 2018: The employer did not initiate and maintain such programs to ensure worker safety, including a program of frequent and regular inspections, person it designates, to ensure workers use appropriate fall protection and to promptly correct safety and health hazards. |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2019-01-15 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2020-03-16 |
Related Activity
Type | Inspection |
Activity Nr | 1364381 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1364375 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2019-02-08 |
Current Penalty | 3978.0 |
Initial Penalty | 5304.0 |
Final Order | 2019-02-28 |
Nr Instances | 2 |
Nr Exposed | 8 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: 1. On or about November 29, 2018, at Building 1 of the Antigua Apartment job site in Saint Augustine, on the east side edge of the 3rd floor, framing employees installing exterior walls were exposed to a 20 feet fall hazard in that they were not protected by a fall protection system. 2. On or about November 29, 2018, at Building 1 of the Antigua Apartment job site in Saint Augustine, on the 3rd floor, a framing employee working from the top plate of an interior wall was exposed to an 8 feet fall hazard in that he was not protected by a fall protection system. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B13 |
Issuance Date | 2019-02-08 |
Current Penalty | 1704.75 |
Initial Penalty | 2273.0 |
Final Order | 2019-02-28 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a. On or about November 29, 2018, at the Antigua Apartments job site in Saint Augustine, on the 3rd Floor of Building 1, a framing employee was exposed to a six feet fall hazard as he used the top step of an A-Frame stepladder to climb up onto the top of the wall. |
Date of last update: 03 Apr 2025