Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-05-10
|
Emphasis |
N: FALL
|
Related Activity
Type |
Complaint |
Activity Nr |
2158836 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2024-10-31 |
Abatement Due Date |
2024-11-27 |
Current Penalty |
2212.2 |
Initial Penalty |
3687.0 |
Final Order |
2024-11-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about May 10, 2024, at the site located at 1481 Wandering Willow Way (Lot 315), Loxahatchee, FL 33470, employees were framing the porch roof, and the employer did not ensure that guardrail systems, safety net systems, fall arrest systems, or alternative fall protection measures were in place to prevent falls from a 10 feet elevation to ground/concrete floor level. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2024-10-31 |
Abatement Due Date |
2024-11-27 |
Current Penalty |
2212.2 |
Initial Penalty |
3687.0 |
Final Order |
2024-11-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) On or about May 10, 2024, at the site located at 1481 Wandering Willow Way (Lot 315), Loxahatchee, FL 33470, employees accessed the porch roof under construction with an extensible aluminum ladder, and the employer did not ensure that the ladder side rails extended at least 3 feet (0.9 m) above the roof porch to prevent falls from a 10 feet elevation to ground/concrete floor level. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19261060 A01 III |
Issuance Date |
2024-10-31 |
Abatement Due Date |
2024-11-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-11-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1060(a)(1)(iii): The employer did not ensure that each employee using ladders and/or stairways had been trained by a competent person in the proper construction, use, placement, and care in handling the ladders and/or stairways: (a) On or about May 10, 2024, at the site located at 1481 Wandering Willow Way (Lot 315), Loxahatchee, FL 33470, employees accessed the porch roof under construction with an extensible aluminum ladder that did not extend at least 3 feet (0.9 m) above the landing surface, and the employer did not ensure that employees had been trained by a competent person in the proper construction, use, placement, and care in handling the ladders and/or stairways to prevent falls from a 10 feet elevation to ground/concrete floor level. |
|
|