Search icon

POWELL ROOFING LLC - Florida Company Profile

Company Details

Entity Name: POWELL ROOFING LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

POWELL ROOFING LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 10 Aug 2023 (2 years ago)
Document Number: L23000376509
FEI/EIN Number 93-2844683

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1144 SW GARDENA AVE, PORT ST LUCIE, FL, 34953, US
Mail Address: 1144 SW GARDENA AVE, PORT ST LUCIE, FL, 34953, US
ZIP code: 34953
County: St. Lucie
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
POWELL ADAM D Manager 1144 SW GARDENA AVE, PORT ST LUCIE, FL, 34953
POWELL ADAM D Agent 1144 SW GARDENA AVE, PORT ST LUCIE, FL, 34953

Documents

Name Date
ANNUAL REPORT 2024-03-06
Florida Limited Liability 2023-08-10

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347484966 0418800 2024-05-13 1910 MAINSAIL CIRCLE, JUPITER, FL, 33477
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-05-16
Emphasis N: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-11-06
Abatement Due Date 2024-11-19
Current Penalty 3457.0
Initial Penalty 3457.0
Final Order 2024-12-05
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about 05/13/2024, at Building 9, 1910 Mainsail Circle, Jupiter, Florida 33477, an employee was exposed to a 30-foot fall hazard while working on the roof of a residential building without being protected from falling with a conventional fall protection system.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2024-11-06
Abatement Due Date 2024-11-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-12-05
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: On or about 5/13/2024, at Building 9, 1910 Mainsail Circle, Jupiter, Florida 33477, the employer did not have a written certificate for fall protection training provided to an employee who was working on the roof of a residential building without being protected from falling.