Search icon

ALMAZANES REMODELING LLC - Florida Company Profile

Company Details

Entity Name: ALMAZANES REMODELING LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

ALMAZANES REMODELING LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 27 Jun 2023 (2 years ago)
Document Number: L23000308870
FEI/EIN Number 92-2094217

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 5119 SUNRISE BLVD, ORLANDO, FL, 32803, US
Mail Address: 5119 SUNRISE BLVD, ORLANDO, FL, 32803, US
ZIP code: 32803
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
RAMIREZ HERNANDEZ ANALIUDY R Authorized Member 5119 SUNRISE BLVD, ORLANDO, FL, 32803
RAMIREZ HERNANDEZ ANALIUDY R Agent 5119 SUNRISE BLVD, ORLANDO, FL, 32803

Documents

Name Date
ANNUAL REPORT 2024-04-02
Florida Limited Liability 2023-06-27

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347465346 0419730 2024-05-07 16435 HAMLIN HILLS RD. BLDG. 5, WINTER GARDEN, FL, 34787
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-05-07
Emphasis N: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2024-05-20
Abatement Due Date 2024-07-09
Current Penalty 2305.0
Initial Penalty 4610.0
Final Order 2024-06-04
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles. a) On or about May 7, 2024, at the jobsite, the employer did not enforce the use of safety glasses, while employees used a nail gun to install decking, exposing employees to struck by hazards.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-05-20
Current Penalty 2305.0
Initial Penalty 4610.0
Final Order 2024-06-04
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about May 7, 2024, at the jobsite, the employer's ladder was only extended approximately 2 feet past the roof landing, while being used to gain access to a roof 20'6" high, with a pitch of 5/12, to install decking, exposing employees to fall hazards.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2024-05-20
Current Penalty 4609.5
Initial Penalty 9219.0
Final Order 2024-06-04
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about May 7, 2024, at the jobsite, the employer did not enforce the use of fall protection, while employees installed decking on a 20'6" high roof, with a pitch of 5/12 exposing employees to fall hazards. Almazanes Remodeling LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1726530, citation number 1, item number 1 and was affirmed as a final order on 03/26/2024, with respect to a workplace located at 16302-16332 Hamlin Hills Bldg. 8, Winter Garden, FL 34787.
Citation ID 03001
Citaton Type Repeat
Standard Cited 19260503 B01
Issuance Date 2024-05-20
Abatement Due Date 2024-07-09
Current Penalty 129.5
Initial Penalty 259.0
Final Order 2024-06-04
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1):The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) On or about May 7, 2024, at the jobsite: the employer did not prepare and maintain a written fall protection training program certification for employees exposed to fall hazards of 20'6" while working on the roof. Almazanes Remodeling LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.503(a)(1), which was contained in OSHA inspection number 1726530, citation number 1, item number 3 and was affirmed as a final order on 03/26/2024, with respect to a workplace located at 16302-16332 Hamlin Hills Bldg. 8, Winter Garden, FL 34787.
347265308 0419730 2024-02-07 16302-16332 HAMLIN HILLS BLDG 8, WINTER GARDEN, FL, 34787
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-02-07
Emphasis N: FALL, P: FALL
Case Closed 2024-05-13

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-03-15
Abatement Due Date 2024-04-03
Current Penalty 2074.2
Initial Penalty 3457.0
Final Order 2024-03-26
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about February 7, 2024, at work site: employees were exposed to fall hazards of approximately 10 feet, in that they were allowed to work on top of the concrete walls of building 8 without fall protection.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2024-03-15
Abatement Due Date 2024-04-03
Current Penalty 2488.8
Initial Penalty 4148.0
Final Order 2024-03-26
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1):The employer did not provide a training program for each employee who might be exposed to fall hazards: a) On or about February 7,2024, at worksite: employees were exposed to an approximate 10 fall hazard, in that the employer did not provide fall protection training.
Citation ID 02001
Citaton Type Other
Standard Cited 19100178 L04 III
Issuance Date 2024-03-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-03-26
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) On or about 2/7/2024 at worksite: Employees were exposed to struck by hazards in that an employee was allowed to operate the JLG 6042 Telehandler who hasn't been re-evaluated since 3/3/2020.