Search icon

G&G ENTERPRISE SERVICES LLC - Florida Company Profile

Company Details

Entity Name: G&G ENTERPRISE SERVICES LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

G&G ENTERPRISE SERVICES LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 13 Jun 2023 (2 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 16 Oct 2024 (7 months ago)
Document Number: L23000286406
FEI/EIN Number 365071067

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 6807 FLAME STREET, ORLANDO, FL, 32807, US
Mail Address: 6807 FLAME STREET, ORLANDO, FL, 32807, US
ZIP code: 32807
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
GARCIA ZELAYA JOSE MARLON A Authorized Member 6807 FLAME STREET, ORLANDO, FL, 32807
GARCIA ZELAYA JOSE MARLON A Agent 6807 FLAME STREET, ORLANDO, FL, 32807

Events

Event Type Filed Date Value Description
REINSTATEMENT 2024-10-16 - -
CHANGE OF PRINCIPAL ADDRESS 2024-10-16 6807 FLAME STREET, ORLANDO, FL 32807 -
CHANGE OF MAILING ADDRESS 2024-10-16 6807 FLAME STREET, ORLANDO, FL 32807 -
REGISTERED AGENT NAME CHANGED 2024-10-16 GARCIA ZELAYA, JOSE MARLON A -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2024-09-27 - -

Documents

Name Date
REINSTATEMENT 2024-10-16
Florida Limited Liability 2023-06-13

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347915019 0419730 2024-12-04 3521 KEYWORTH STREET LOT 1, APOPKA, FL, 32712
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2024-12-04

Related Activity

Type Inspection
Activity Nr 1771269
Safety Yes

Violation Items

Citation ID 02001
Citaton Type Repeat
Standard Cited 19260503 B01
Issuance Date 2024-12-27
Current Penalty 322.0
Initial Penalty 322.0
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1):The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a. On or about December 4,2024, at the worksite: the employer did not provide written fall protection training certificates for employees conducting roofing activities. The employer G&G Enterprise Services LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1771269, citation number 2, item number 1 and was affirmed as a final order on 10-11-2024, with respect to a workplace located at 3521 Keyworth Street Apopka, Fl 32712.
347712697 0419730 2024-08-26 3521 KEYWORTH STREET LOT 1, APOPKA, FL, 32712
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-08-26
Emphasis N: FALL, P: FALL

Related Activity

Type Inspection
Activity Nr 1771069
Safety Yes
Type Inspection
Activity Nr 1771072
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260095 D01
Issuance Date 2024-09-17
Abatement Due Date 2024-10-21
Current Penalty 8067.0
Initial Penalty 8067.0
Final Order 2024-10-11
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.95(d)(1): Except as provided by paragraphs (d)(2) through (d)(6) of this section, the protective equipment, including personal protective equipment (PPE), used to comply with this part, was not provided by the employer at no cost to employee(s). a. On or about August 26, 2024, at Lot 1: the employer did not provide the necessary PPE at no cost to the employees (fall, eye and head protection) while conducting roofing activities, exposing employees to eye injury, falls and struck by hazards. Employees purchased their own personal protective equipment.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-09-17
Current Penalty 11292.0
Initial Penalty 11292.0
Final Order 2024-10-11
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). a. On or about August 26, 2024, at Lot 1: employees were exposed to 14 foot 7 inch fall hazards while decking on a 5/12 pitched roof, in that a fall protection system was not used. b. On or about August 26, 2024, at Lot 1: employees were exposed to 9 foot 10 inch fall hazards while decking on a 5/12 pitched roof, in that a fall protection system was not used.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-09-17
Current Penalty 8067.0
Initial Penalty 8067.0
Final Order 2024-10-11
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. a. On or about August 26, 2024, at Lot 1: employees were exposed to a 10 foot fall hazard, in that a multi-position ladder was used extended approximately 10 inches above the landing to access a 5/12 pitch residential roof.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2024-09-17
Abatement Due Date 2024-10-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-10-11
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1):The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a. On or about August 26, 2024, at Lot 1: the employer did not prepare and maintain a written fall protection training certification for employees exposed to fall hazards of 14 feet 7 inches while working on the roof. b. On or about August 26, 2024, at Lot 1: the employer did not prepare and maintain a written fall protection training certification for employees exposed to fall hazards of 9 feet 10 inches while working on the roof.

Date of last update: 02 Apr 2025