Search icon

JPE CONSTRUCTION OF ALABAMA LLC - Florida Company Profile

Headquarter

Company Details

Entity Name: JPE CONSTRUCTION OF ALABAMA LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

JPE CONSTRUCTION OF ALABAMA LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 24 May 2023 (2 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 06 Nov 2024 (4 months ago)
Document Number: L23000253440
FEI/EIN Number 47-2012643

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 4758 DAVIS LANE, CRESTVIEW, FL, 35239, US
Mail Address: 4758 DAVIS LANE, CRESTVIEW, FL, 35239, US
Place of Formation: FLORIDA

Links between entities

Type Company Name Company Number State
Headquarter of JPE CONSTRUCTION OF ALABAMA LLC, MISSISSIPPI 1381993 MISSISSIPPI

Key Officers & Management

Name Role Address
ESPARZA JUAN LUIS Manager 4758 DAVIS LANE, CRESTVIEW, FL, 35239
LISTON BARBARA Agent 4758 DAVIS LANE, CRESTVIEW, FL, 35239

Events

Event Type Filed Date Value Description
REINSTATEMENT 2024-11-06 - -
REGISTERED AGENT NAME CHANGED 2024-11-06 LISTON, BARBARA -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2024-09-27 - -
CONVERSION 2023-05-24 - CORPORATION WAS A CONVERSION RESULT. CONVERTING CORPORATION WAS. CONVERSION NUMBER 900000240459

Documents

Name Date
REINSTATEMENT 2024-11-06
Florida Limited Liability 2023-05-24

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346327109 0420600 2022-11-04 14011 US HIGHWAY 301 S, RIVERVIEW, FL, 33578
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2022-11-04
Emphasis P: FORKLIFT, N: CTARGET, L: FORKLIFT
Case Closed 2023-06-16

Related Activity

Type Inspection
Activity Nr 1632711
Safety Yes
Type Inspection
Activity Nr 1632712
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100178 L04 III
Issuance Date 2022-12-14
Abatement Due Date 2023-01-11
Current Penalty 2983.5
Initial Penalty 3315.0
Final Order 2023-01-05
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) For the construction site at 14011 US Highway 301 S, Riverview, FL 33578, on or about 11/04/2022, the employer exposed employees to struck-by hazards, in that, operators of rough terrain forklifts had not been trained or evaluated in the last three years.
346318603 0419730 2022-11-02 2321 WILLET PLACE, MELBOURNE, FL, 32940
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2022-11-02
Emphasis L: FALL, P: FALL
Case Closed 2024-03-12

Related Activity

Type Referral
Activity Nr 1964011
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2023-05-02
Current Penalty 2500.0
Initial Penalty 4911.0
Final Order 2023-06-02
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1):Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) On or about November 2, 2022 at 2321 Willet Place Melbourne, FL 32940 two workers were working from a roof of a three-story building that was being constructed without proper fall protection, exposing employees to a fall hazard of approximately 3 stories.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2023-05-02
Current Penalty 2500.0
Initial Penalty 4911.0
Final Order 2023-06-02
Nr Instances 1
Nr Exposed 12
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) At the job site: On or about November 2, 2022: employees were exposed to fall hazards, in that, the top step of a 6 foot A-frame ladder was used to gain access to the roof.
Citation ID 02001
Citaton Type Other
Standard Cited 19260025 A
Issuance Date 2023-05-02
Current Penalty 500.0
Initial Penalty 551.0
Final Order 2023-06-02
Nr Instances 1
Nr Exposed 12
Related Event Code (REC) Referral
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures a) On or about November 2, 2022 employees were exposed to housekeeping hazards as construction site had debris such as scrap wood, nails, air hose lines other other type of debris in the passageways, stairs and walkways.

Date of last update: 01 Mar 2025

Sources: Florida Department of State