Search icon

BLESSINGS ZACARIAS CONSTRUCTION LLC - Florida Company Profile

Company Details

Entity Name: BLESSINGS ZACARIAS CONSTRUCTION LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

BLESSINGS ZACARIAS CONSTRUCTION LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 25 Apr 2023 (2 years ago)
Document Number: L23000204162
FEI/EIN Number 37-2092470

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 222 BLAIMORE BLVD, UNIT 54, ORANGE PARK, FL, 32073
Mail Address: 222 BLAIMORE BLVD, UNIT 54, ORANGE PARK, FL, 32073
ZIP code: 32073
County: Clay
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ZACARIAS CESAR ESR Manager 222 BLAIMORE BLVD, UNIT 54, ORANGE PARK, FL, 32073
ZACARIAS CESAR ESR Agent 222 BLAIMORE BLVD, ORANGE PARK, FL, 32073

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2025-01-29 ZACARIAS, CESAR ELIAS -

Documents

Name Date
ANNUAL REPORT 2025-01-29
ANNUAL REPORT 2024-04-29
Florida Limited Liability 2023-04-25

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347792772 0419700 2024-10-03 286 ORATE CIRCLE, SAINT AUGUSTINE, FL, 32084
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2024-10-03
Emphasis N: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2024-10-22
Current Penalty 1735.0
Initial Penalty 2939.0
Final Order 2024-12-13
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. At 286 Orate Circle, Saint Augustine Florida: On or about October 3, 2024, the employer exposed roofing employees to eye injury hazards in that employees using pneumatic nail guns were not wearing safety glasses to protect from flying debris.
Citation ID 02001
Citaton Type Other
Standard Cited 19261053 B01
Issuance Date 2024-10-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-12-13
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. At 286 Orate Circle, Saint Augustine Florida: On or about October 3, 2024, the employer exposed employees to a 10-foot fall hazard in that ladder used to access the roof did not extend at least 3 feet above the upper landing of the roof.
Citation ID 03001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-10-22
Current Penalty 5765.0
Initial Penalty 9679.0
Final Order 2024-12-13
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. 4210 Oriole Avenue, Port Orange, FL; On or about March 17, 2023, the employer exposed employees to a 15-foot fall hazard, in that they were not protected by a fall protection system. Blessings Zacarias Construction, LLC. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(10), which was contained in OSHA inspection number 1741675, citation number 01, item number 001 and was affirmed as a final order on May 24, 2024, with respect to a workplace located at 5337 Beach Blvd., Jacksonville, FL 32207.
347416752 0419700 2024-04-16 5337 BEACH BLVD, JACKSONVILLE, FL, 32207
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2024-04-16
Emphasis N: FALL
Case Closed 2024-11-05

Related Activity

Type Complaint
Activity Nr 2152480
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2024-04-29
Current Penalty 2074.2
Initial Penalty 3457.0
Final Order 2024-05-24
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10):Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. a. Located at 5337 Beach Blvd, Jacksonville, Florida, 32207 the employer exposed employees to fall hazards in that in that employees were working on a metal roof not wearing a fall protection system.

Date of last update: 01 Apr 2025