Entity Name: | 1 AMERICA UNITED CONSTRUCTION SOLUTIONS LLC |
Jurisdiction: | FLORIDA |
Filing Type: | Florida Limited Liability Company |
Status: | Active |
Date Filed: | 15 Mar 2023 (2 years ago) |
Document Number: | L23000133299 |
FEI/EIN Number | 92-3540792 |
Address: | 2950 English Oak Circle, PENSACOLA, FL 32526 |
Mail Address: | 2950 English Oak Circle, PENSACOLA, FL 32526 |
ZIP code: | 32526 |
County: | Escambia |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
ZUNIGA, KAREN M | Agent | 2950 English Oak Circle, PENSACOLA, FL 32526 |
Name | Role | Address |
---|---|---|
ZUNIGA, KAREN M | Manager | 2950 English Oak Circle, PENSACOLA, FL 32526 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2024-04-30 | 2950 English Oak Circle, PENSACOLA, FL 32526 | No data |
CHANGE OF MAILING ADDRESS | 2024-04-30 | 2950 English Oak Circle, PENSACOLA, FL 32526 | No data |
REGISTERED AGENT ADDRESS CHANGED | 2024-04-30 | 2950 English Oak Circle, PENSACOLA, FL 32526 | No data |
Name | Date |
---|---|
ANNUAL REPORT | 2024-04-30 |
Florida Limited Liability | 2023-03-15 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347438954 | 0418600 | 2024-04-25 | 15650 PERDIDO KEY DRIVE, PENSACOLA, FL, 32507 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100178 L01 I |
Issuance Date | 2024-05-01 |
Abatement Due Date | 2024-05-15 |
Current Penalty | 2765.0 |
Initial Penalty | 2765.0 |
Final Order | 2024-06-21 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l) and as referenced by the note contained in 1926.602(d) : a) At 15650 Perdido Key Drive, Pensacola, Florida: On April 25, 2024; the employer allowed his employees to to operate a Tele-Handler on site and the employees were not trained and certified on its operations exposing employees to struck-by hazards. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2024-05-01 |
Current Penalty | 2765.0 |
Initial Penalty | 2765.0 |
Final Order | 2024-06-21 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles: a) At 15650 Perdido Key Drive, Pensacola, Florida: On April 25, 2024; the employer allowed his employees to operate pneumatic nail guns without eye protection exposing his employees to struck-by hazards. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2024-05-01 |
Abatement Due Date | 2024-05-15 |
Current Penalty | 4839.0 |
Initial Penalty | 4839.0 |
Final Order | 2024-06-21 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At 15650 Perdido Key Drive, Pensacola, Florida: On April 25, 2024; the employer allowed his employees to perform framing activities without fall protection exposing his employees to a fall hazard of up to 40 feet to the ground below. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2024-05-01 |
Abatement Due Date | 2024-05-15 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-06-21 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) At 15650 Perdido Key Drive, Pensacola, Florida: On April 25, 2024; the employer allowed his employees to perform framing activities without first ensuring his crew was trained on the hazards associated with falls to include but not limited to setting up and inspecting fall protection exposing his employee to a fall hazard of up to 40 feet to the ground below. |