Search icon

KNIGHTS LABOR UNLIMITED LLC - Florida Company Profile

Company Details

Entity Name: KNIGHTS LABOR UNLIMITED LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

KNIGHTS LABOR UNLIMITED LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 24 Jan 2023 (2 years ago)
Document Number: L23000043548
FEI/EIN Number 922057236

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3763 RAMBLING ROSE CT, ORLANDO, FL, 32808, US
Mail Address: 3763 RAMBLING ROSE CT, ORLANDO, FL, 32808, US
ZIP code: 32808
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
WHITTED JEFFREY ASR Authorized Member 3763 RAMBLING ROSE CT, ORLANDO, FL, 32808
MITCHELL JOHANA Agent 807 MCFALL AVE, ORLANDO, FL, 32805

Documents

Name Date
ANNUAL REPORT 2024-04-30
Florida Limited Liability 2023-01-24

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347098329 0420600 2023-11-02 22762 CHEROKEE ROSE PLACE, LAND O LAKES, FL, 34639
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2023-11-02
Emphasis N: FALL

Related Activity

Type Referral
Activity Nr 2101469
Safety Yes
Type Inspection
Activity Nr 1709600
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2024-01-03
Current Penalty 3795.0
Initial Penalty 3795.0
Final Order 2024-02-13
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying objects while using a nail gun. a) On or about 11/02/2023, at the jobsite located at 22762 Cherokee Rose Place, Land O' Lakes, Florida 34639 employees were exposed to eye injuries, in that, appropriate eye protection was not utilized while using a nail gun.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-01-03
Current Penalty 3795.0
Initial Penalty 3795.0
Final Order 2024-02-13
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about 11/02/2023, at the jobsite located at 22762 Cherokee Rose Place, Land O' Lakes, Florida 34639 employees were exposed to fall hazards of approximately 10 feet, in that, fall protection was not used while engaged in roofing activities while working on the roof.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B05 I
Issuance Date 2024-01-03
Current Penalty 3795.0
Initial Penalty 3795.0
Final Order 2024-02-13
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support) a) On or about 11/02/2023, at the jobsite located at 22762 Cherokee Rose Place, Land O' Lakes, Florida 34639 employees were exposed to fall hazards of approximately 10 feet, in that, the angle of the extension ladder in use to gain access to the roof was too shallow, 64.2 degrees.