Search icon

JGL FRAMING LLC - Florida Company Profile

Company Details

Entity Name: JGL FRAMING LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

JGL FRAMING LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 17 Aug 2022 (3 years ago)
Document Number: L22000363074
FEI/EIN Number APPLIED FOR

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 7514 HOGAN RD APT 1102, JACKSONVILLE, FL, 32216, US
Mail Address: 7514 HOGAN RD APT 1102, JACKSONVILLE, FL, 32216, US
ZIP code: 32216
County: Duval
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MESQUITE BUSINESS SOLUTION INC Agent -
SANCHEZ RIOS RUBEN Manager 7514 HOGAN RD APT 1102, JACKSONVILLE, FL, 32216

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G22000115014 JGL REMODELING SERVICES ACTIVE 2022-09-13 2027-12-31 - 7514 HOGAN RD APT 1102, JACKSONVILLE, FL, 32216

Documents

Name Date
ANNUAL REPORT 2024-01-03
ANNUAL REPORT 2023-01-04
Florida Limited Liability 2022-08-17

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346794688 0419700 2023-06-27 161 ARCHSTONE WAY, SAINT AUGUSTINE, FL, 32092
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2023-06-27
Emphasis N: FALL, P: FALL
Case Closed 2023-09-11
346727662 0419700 2023-05-25 467 SILVER LANDING DRIVE, SAINT AUGUSTINE, FL, 32092
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2023-05-25
Emphasis N: FALL, P: FALL
Case Closed 2024-11-26

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2023-09-11
Current Penalty 2009.0
Initial Penalty 2009.0
Final Order 2023-10-12
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1):The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a. On or about May 25, 2023, the employer exposed employees to eye injury hazards caused by airborne debris and flying objects, in that eye protection were not utilized by an employee, while using pneumatic nail guns to put in floorboards.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2023-09-11
Abatement Due Date 2023-10-05
Current Penalty 2679.0
Initial Penalty 2679.0
Final Order 2023-10-12
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: At 467 Silver Landing Drive, Saint Augustine, Florida. On or about May 25, 2023, on the second floor of a residential house, the employer exposed 2 framing employees to an 8-foot fall hazard from the second floor through floor joists in that they were not protected by a fall protection system while installing joists, floor boards, and framing.
346584337 0419700 2023-03-23 477 SILVERLEAF DRIVE, SAINT AUGUSTINE, FL, 32092
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2023-03-23
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2023-04-10
Abatement Due Date 2023-05-04
Current Penalty 4688.0
Initial Penalty 4688.0
Final Order 2023-05-25
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. At 477 Silverleaf Drive, Saint Augustine, FL: On or about March 23, 2023, the employer exposed employees to fall hazards, in that the crew leader was working on roof sheathing 16 feet, 4 inches high.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260502 E02
Issuance Date 2023-04-10
Abatement Due Date 2023-05-04
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-05-25
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(e)(2):Positioning devices shall be secured to an anchorage capable of supporting at least twice the potential impact load of an employee's fall or 3,000 pounds (13.3 kN), whichever is greater. a. At 477 Silverleaf Drive, Saint Augustine, FL: On or about March 23, 2023, the employer was exposing employees to fall hazards, in that employees were not using an ANSI rated anchor device.
346457088 0419700 2023-01-24 147 HOLLY FOREST DRIVE, SAINT AUGUSTINE, FL, 32092
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2023-01-24
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2023-04-25
Current Penalty 4018.0
Initial Penalty 4018.0
Final Order 2023-05-25
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. At 147 Holly Forest Drive: On or about January 24, 2023, the employer exposed three framing employees to a 9-foot fall hazard, in that the employees were not protected by a fall protection system while working above and inside the open roof trusses.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2023-04-25
Abatement Due Date 2023-05-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-05-25
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards. a. At 147 Holly Forest Drive, Saint Augustine, FL: On or about January 24, 2022, the employer had not trained employees who worked at elevations to recognize the hazards of falling or the procedures to minimize these risks.

Date of last update: 02 Apr 2025