Search icon

AWP SITE DEVELOPMENT LLC - Florida Company Profile

Company Details

Entity Name: AWP SITE DEVELOPMENT LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

AWP SITE DEVELOPMENT LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 04 Aug 2022 (3 years ago)
Document Number: L22000344819
FEI/EIN Number 883606925

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 113 W WOODWARD AVE, EUSTIS, FL, 32726, US
Mail Address: Post Office Box 228, Umatilla, FL, 32784, US
ZIP code: 32726
County: Lake
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
POUNDERS ALLEN W Manager 113 W WOODWARD AVE, EUSTIS, FL, 32726
Pounders Sarah J Admi 113 W WOODWARD AVE, EUSTIS, FL, 32726
UNITED STATES CORPORATION AGENTS, INC. Agent -

Events

Event Type Filed Date Value Description
CHANGE OF MAILING ADDRESS 2025-02-03 113 W WOODWARD AVE, Suite 2, EUSTIS, FL 32726 -
REGISTERED AGENT ADDRESS CHANGED 2023-02-18 476 RIVERSIDE AVE., JACKSONVILLE, FL 32202 -
CHANGE OF PRINCIPAL ADDRESS 2023-01-04 113 W WOODWARD AVE, Suite 2, EUSTIS, FL 32726 -
CHANGE OF MAILING ADDRESS 2023-01-04 113 W WOODWARD AVE, Suite 2, EUSTIS, FL 32726 -

Documents

Name Date
ANNUAL REPORT 2025-02-03
ANNUAL REPORT 2024-02-09
ANNUAL REPORT 2023-01-04
Florida Limited Liability 2022-08-04

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346543317 0419730 2023-03-02 12500 LAKE UNDERHILL RD, ORLANDO, FL, 32828
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2023-03-02
Emphasis N: TRENCH, P: TRENCH
Case Closed 2024-06-25

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260021 B02
Issuance Date 2023-08-18
Abatement Due Date 2023-09-07
Current Penalty 0.0
Initial Penalty 4465.0
Final Order 2023-09-13
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) On or about March 02, 2023 at 12500 Lake Underhill Rd, untrained employees were directed to work in a excavation that was approximately 10 feet deep, with vertical sides, and Class C soil.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2023-08-18
Current Penalty 2275.0
Initial Penalty 3572.0
Final Order 2023-09-13
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a.) On or about March 02, 2023 at 12500 Lake Underhill Rd, employees did not wear hard hats while working inside a 10-foot deep excavation and unhooking loads from underneath the excavator bucket.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260651 C02
Issuance Date 2023-08-18
Current Penalty 4000.0
Initial Penalty 6250.0
Final Order 2023-09-13
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) On or about March 02, 2023 at 12500 Lake Underhill Rd untrained employees were directed to work in an excavation that was approximately 10 feet deep, with vertical sides, in class C soil, in that a safe means of egress was 35 feet away while replacing a sewer pipe, exposing employees to crush-by hazards.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260652 A01
Issuance Date 2023-08-18
Abatement Due Date 2023-09-29
Current Penalty 4000.0
Initial Penalty 6250.0
Final Order 2023-09-13
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). a.) On or about March 02, 2023 at 12500 Lake Underhill Rd employees exposed to a cave in hazard in that employees were not protected by a trench box or other type of protection while working in a 10 foot deep excavation with Class C Soil and vertical walls.

Date of last update: 03 Apr 2025

Sources: Florida Department of State