4D INSPIRATION COMPANY LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 09 Jun 2022 (3 years ago)
Last Event: LC NAME CHANGE
Event Date Filed: 24 Jun 2022 (3 years ago)
Document Number: L22000264384
FEI/EIN Number 92-0440495

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 128 JALAPA DR, KISSIMME, FL, 34743, US
Mail Address: 128 JALAPA DR, KISSIMME, FL, 34743, US
ZIP code: 34743
County: Osceola
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MORAN OSMERBY President 128 JALAPA DR, KISSIMME, FL, 34743
MORAN OSMERBY A Agent 128 JALAPA DR, KISSIMME, FL, 34743

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2023-03-22 128 JALAPA DR, KISSIMME, FL 34743 -
CHANGE OF MAILING ADDRESS 2023-03-22 128 JALAPA DR, KISSIMME, FL 34743 -
LC NAME CHANGE 2022-06-24 4D INSPIRATION COMPANY LLC -

Documents

Name Date
ANNUAL REPORT 2024-05-01
ANNUAL REPORT 2023-03-22
LC Name Change 2022-06-24
Florida Limited Liability 2022-06-09

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346754534 0419730 2023-06-05 2011 PEEL AVE LOT 4, ORLANDO, FL, 32806
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2023-06-05
Emphasis L: FALL, P: FALL

Related Activity

Type Referral
Activity Nr 2072515
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2023-09-21
Current Penalty 2209.9
Initial Penalty 4018.0
Final Order 2023-10-12
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1):The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying objects while using a nail gun. a) On or about June 5, 2023 at the jobsite located at the new multi residence construction 2011 Peel Ave. Orlando, FL 32811 Lot 4, the employer did not enforce the use of eye protection while nailing the second story roof trusses using a pneumatic nail gun/pneu-tools SN2283H 1-3/4in. classic coil roofing nailer, exposing employees to a eye and/or facial hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2023-09-21
Current Penalty 2578.4
Initial Penalty 4688.0
Final Order 2023-10-12
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about June 5, 2023, at the jobsite located at the New multi residence construction 2011 Peel Ave. Orlando, FL 32811 Lot 4, fall protection was not enforce by the employer while conducting framing activities, exposing employees to a 19'5" fall hazard.
Citation ID 01003
Citaton Type Other
Standard Cited 19260503 A01
Issuance Date 2023-09-21
Abatement Due Date 2023-10-18
Current Penalty 1841.95
Initial Penalty 3349.0
Final Order 2023-10-12
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1):The employer did not provide a training program for each employee who might be exposed to fall hazards. a) On or about June 5, 2023, at the jobsite located at the New multi residence construction 2011 Peel Ave. Orlando, FL 32811 Lot 4, the employer did not provide fall protection training and certification to employees engaged in framing activities, exposing employees to fall hazards.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261052 C12
Issuance Date 2023-09-21
Current Penalty 1841.95
Initial Penalty 3349.0
Final Order 2023-10-12
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(12):Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926. a) On or about June 5, 2023, at the jobsite located at new multi residence construction 2011 Peel Ave. Orlando, FL 32811 Lot 4, guardrail system was not used on the stairs opening that access the second level of the residence to install roof trusses, exposing employees to fall hazards of approximately 8 feet, through the stairwell opening.