Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-06-06
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2024-12-06
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2023-08-09 |
Current Penalty |
1607.4 |
Initial Penalty |
2679.0 |
Final Order |
2023-09-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: a. On a roof of a new multifamily residential, at a temporary worksite located at 1095 Farwell Street, in Jacksonville, FL: On or about June 6, 2023, the employer exposed employees to eye injuries, in that eye protection was not utilized by employees who were operating pneumatic nail guns. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2023-08-09 |
Current Penalty |
2812.8 |
Initial Penalty |
4688.0 |
Final Order |
2023-09-11 |
Nr Instances |
3 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a. On a 10:12 pitch roof of a new multifamily residential, at a temporary worksite located at 1095 Farwell Street, in Jacksonville, FL: On or about June 6, 2023, the employer, exposed employees to fall hazard, in that fall protection was not utilized by employees while performing sheathing work. b. At a new multifamily residential construction, at a temporary worksite located at 1095 Farwell Street, in Jacksonville, FL: On or about June 6, 2023, the employer, exposed employees to fall hazard, in that fall protection was not utilized by employees while performing framing work at the joist level. c. On a balcony of a new multifamily residential, at a temporary worksite located at 1095 Farwell Street, in Jacksonville, FL: On or about June 6, 2023, the employer, exposed employees to 20.4' fall hazard, in that fall protection was not utilized by employees while unloading plywood from the forklift. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261051 A |
Issuance Date |
2023-08-09 |
Current Penalty |
1607.4 |
Initial Penalty |
2679.0 |
Final Order |
2023-09-11 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a. On a new multifamily residential, at a temporary worksite located at 1095 Farwell Street, in Jacksonville, FL: On or about June 6, 2023, the employer exposed employees to fall hazards, in that they were not provided with a ladder or stairs to access the web frames of the trusses. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260503 A01 |
Issuance Date |
2023-08-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-09-11 |
Nr Instances |
1 |
Nr Exposed |
8 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a. At a temporary worksite located at 1095 Farwell Street, in Jacksonville, FL: On or about June 6, 2023, the employer exposed employees to fall hazards, in that employees performing roofing activities had not been trained to recognize fall hazards. |
|
|