Search icon

ORCHIDS BUILDERS, LLC - Florida Company Profile

Company Details

Entity Name: ORCHIDS BUILDERS, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

ORCHIDS BUILDERS, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 02 Mar 2022 (3 years ago)
Document Number: L22000108613
FEI/EIN Number 881266267

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 6101 BLUE DUCK LN, SUIT 20, ORLANDO, FL, 32809, US
Mail Address: 6101 BLUE DUCK LANE, ORLANDO, FL, 32809, US
ZIP code: 32809
County: Orange
Place of Formation: FLORIDA

form 5500

Plan Name Plan Year EIN/PN Received Sponsor Total number of participants
ORCHIDS BUILDERS LLC 401K PLAN 2023 881266267 2024-09-04 ORCHIDS BUILDERS LLC 23
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2023-02-01
Business code 236110
Sponsor’s telephone number 8709397057
Plan sponsor’s address 6101 BLUE DUCK LN, APT 20, ORLANDO, FL, 32809

Signature of

Role Plan administrator
Date 2024-09-04
Name of individual signing SHIRLEY HORNER
Valid signature Filed with authorized/valid electronic signature

Key Officers & Management

Name Role Address
COELLO PINTO CINTYA M Authorized Person 6101 BLUE DUCK LANE UNIT #20, ORLANDO, FL, 32809
FILE FLORIDA CO. Agent 7021 UNIVERSITY BLVD, WINTER PARK, FL, 32792

Events

Event Type Filed Date Value Description
REGISTERED AGENT ADDRESS CHANGED 2024-01-19 7021 UNIVERSITY BLVD, WINTER PARK, FL 32792 -
CHANGE OF PRINCIPAL ADDRESS 2024-01-03 6101 BLUE DUCK LN, SUIT 20, ORLANDO, FL 32809 -
CHANGE OF MAILING ADDRESS 2024-01-03 6101 BLUE DUCK LN, SUIT 20, ORLANDO, FL 32809 -
REGISTERED AGENT NAME CHANGED 2023-02-11 FILE FLORIDA CO. -

Documents

Name Date
ANNUAL REPORT 2024-01-03
ANNUAL REPORT 2023-02-11
Florida Limited Liability 2022-03-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347938706 0419730 2024-12-16 COMMON AREA, WINTER GARDEN, FL, 34787
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-12-17
Emphasis N: FALL, P: FALL

Related Activity

Type Inspection
Activity Nr 1793876
Safety Yes
347878605 0419730 2024-11-14 2641 TYRON PLACE, WINDERMERE, FL, 34786
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-11-14
Emphasis P: FALL, N: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2024-11-25
Current Penalty 3318.6
Initial Penalty 5531.0
Final Order 2025-01-14
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1):29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles. a) On or about November 14, 2024, at the jobsite: the employer did not enforce the use of safety glasses while employees used nail guns to install shingles, exposing employees to eye injury hazards.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-11-25
Current Penalty 3871.2
Initial Penalty 6452.0
Final Order 2025-01-14
Nr Instances 1
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about November 14, 2024, at the jobsite: the employer's ladder was only extended approximately 2 feet past the roof landing, while being used to gain access to a roof approximately 14'5" high, with a pitch of 5/12, exposing employees to fall hazards.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2024-11-25
Current Penalty 7743.0
Initial Penalty 12905.0
Final Order 2025-01-14
Nr Instances 1
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about November 14, 2024, at the jobsite: the employer did not enforce the use of fall protection while employees installed shingles on a 10'2" high roof, with a pitch of 5/12, exposing employees to fall hazards. The Orchids Builders, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1659563, citation number 1, item number 1 and was affirmed as a final order on 9/7/2023, with respect to a workplace located at 2511 Windermere Reserve Ct. Windermere, FL 34786.
Citation ID 03001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2024-11-25
Abatement Due Date 2025-01-14
Current Penalty 310.8
Initial Penalty 518.0
Final Order 2025-01-14
Nr Instances 1
Nr Exposed 7
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) On or about November 14, 2024, at the jobsite: the employer did not prepare and maintain a written fall protection training program certification for employees exposed to fall hazards of up to 14'5" while working on the roof.
347817884 0419730 2024-10-15 3814 GREAT SMOKEY WAY LOT 135, APOPKA, FL, 32712
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-10-16
Emphasis N: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2024-12-13
Current Penalty 8517.0
Initial Penalty 14195.0
Final Order 2025-01-14
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a.) At the jobsite located at 1490 Pine Cliff Dr Apopka Fl 32703 Lot 175, the employer did not enforce the use of fall protection while employees were installing plywood decking and engineer trusses ranging from 10-20 feet in the air, on a 5:12 pitch roof. The Orchids Builders, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1659563, citation number 1, item number 1 and was affirmed as a final order on 09/07/2023, with respect to a workplace located at 2511 Windermere Reserve Ct., Windermere Florida 34786.
347786519 0419730 2024-10-01 1490 PINCLIFF DR LOT 175, APOPKA, FL, 32703
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2024-10-01
Emphasis P: FALL, N: FALL

Related Activity

Type Inspection
Activity Nr 1778604
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2024-11-08
Abatement Due Date 2024-11-29
Current Penalty 8517.0
Initial Penalty 14195.0
Final Order 2025-01-14
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a.) On or about October 1, 2024, at the jobsite located at 1490 Pine Cliff Dr., Apopka Fl 32703 Lot 175: employees were exposed to an approximate 10 foot 10 inch fall hazard while installing waterproofing roof tape on a 4:12 pitched roof, in that, fall protection was not used. The Orchids Builders, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1659563, citation number 1, item number 1 and was affirmed as a final order on 09/07/2023, with respect to a workplace located at 2511 Windermere Reserve Ct., Windermere Florida 34786.
346595630 0419730 2023-03-28 2511 WINDERMERE RESERVE CT., WINDERMERE, FL, 34786
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2023-03-28
Emphasis L: FALL
Case Closed 2024-03-08

Related Activity

Type Referral
Activity Nr 2014951
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2023-07-18
Abatement Due Date 2023-08-04
Current Penalty 4687.5
Initial Penalty 6250.0
Final Order 2023-09-07
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a.) At the jobsite located at 2511 Windermere Reserve Ct. Windermere, FL 34786, the employer did not provide fall protection while employees installed trusses and framework on a twelve (12) feet high roof, exposing employees to fall hazards, on or about 03/28/2023. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.

Date of last update: 01 Apr 2025

Sources: Florida Department of State