Search icon

TRUE FORCE ROOFING LLC - Florida Company Profile

Company Details

Entity Name: TRUE FORCE ROOFING LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

TRUE FORCE ROOFING LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 28 Jan 2022 (3 years ago)
Last Event: LC AMENDMENT
Event Date Filed: 13 Jun 2023 (2 years ago)
Document Number: L22000050102
FEI/EIN Number 880632256

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2420 NW 66TH CT., BUILDING B, GAINESVILLE, FL, 32653, US
Mail Address: 2420 NW 66TH CT., BUILDING B, GAINESVILLE, FL, 32653, US
ZIP code: 32653
County: Alachua
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
KING DEREK J Manager 11740 NW 72ND TERR, ALACHUA, FL, 32615
Carter Andrew W Chief Operating Officer 2420 NW 66TH CT., BUILDING B, GAINESVILLE, FL, 32653
KING DEREK J Agent 11740 NW 72ND TERR, ALACHUA, FL, 32615

Events

Event Type Filed Date Value Description
REGISTERED AGENT ADDRESS CHANGED 2025-01-30 2114 NW 40th Terr., Suite D-2, GAINESVILLE, FL 32605 -
REGISTERED AGENT NAME CHANGED 2025-01-28 Law Office of Thomas McDermott, LLC -
CHANGE OF PRINCIPAL ADDRESS 2023-07-25 2420 NW 66TH CT., BUILDING B, GAINESVILLE, FL 32653 -
CHANGE OF MAILING ADDRESS 2023-07-25 2420 NW 66TH CT., BUILDING B, GAINESVILLE, FL 32653 -
LC AMENDMENT 2023-06-13 - -

Documents

Name Date
AMENDED ANNUAL REPORT 2025-01-30
ANNUAL REPORT 2025-01-28
AMENDED ANNUAL REPORT 2024-04-16
ANNUAL REPORT 2024-01-18
LC Amendment 2023-06-13
ANNUAL REPORT 2023-02-21
Florida Limited Liability 2022-01-28

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347980641 0419700 2025-01-15 5730 NW STATE ROAD 45, NEWBERRY, FL, 32669
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2025-01-15
Emphasis N: FALL

Related Activity

Type Referral
Activity Nr 2250176
Safety Yes
347765265 0419700 2024-09-17 2604 SW 87TH WAY, GAINESVILLE, FL, 32608
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2024-09-18
Emphasis N: FALL
Case Closed 2025-01-21

Related Activity

Type Complaint
Activity Nr 2212859
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2024-11-04
Current Penalty 2467.8
Initial Penalty 4113.0
Final Order 2024-11-20
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On the ground around the 5-attached residences, located at 2604 S.W. 87th Way, Gainesville, FL,: on or about September 17, 2024, the employer exposed employees to head injuries from impact from falling or flying objects, in that hard hat protection was not used by employees when cleaning roofing debris from the yard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2024-11-04
Current Penalty 4114.2
Initial Penalty 6857.0
Final Order 2024-11-20
Nr Instances 2
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1):The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a. On the 6:12 pitch roof of the 5 - attached multi-family condominiums, at 2604 SW 87th Way, Gainesville, FL: On or about September 17, 2024, the employer exposed employees to eye hazards from flying projectile nails from pneumatic nailers, and other flying debris, in that eye protection was not used by the operators of the pneumatic nailers. b. On the ground, located at 2604 S.W. 87th Way, Gainesville, FL,: on or about September 17, 2024, the employer exposed employees to eye hazards from flying projectile wood chips from the circular saw, and other flying debris, in that eye protection was not used by the operators of the circular saw.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-11-04
Current Penalty 4936.8
Initial Penalty 8228.0
Final Order 2024-11-20
Nr Instances 1
Nr Exposed 12
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On the 6:12 pitch roof of the 5 - attached multi-family condominiums, at 2604 SW 87th Way, Gainesville, FL: On or about September 17, 2024, the employer exposed employees to fall hazards, in that fall protection was not utilized by the employees while performing roofing work.