Entity Name: | SUNNY DAYS CONSTRUCTION AND REMODELING LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Company
SUNNY DAYS CONSTRUCTION AND REMODELING LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 13 Dec 2021 (3 years ago) |
Document Number: | L21000524313 |
FEI/EIN Number |
87-4205015
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 10214 DOVEHILL LN, CLERMONT, FL 34711 |
Mail Address: | 10214 DOVEHILL LN, CLERMONT, FL 34711 |
ZIP code: | 34711 |
County: | Lake |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
OMAR, GUARDADO | Agent | 10214 DOVEHILL LN, CLERMONT, FL 34711 |
GUARDADO DELGADO, OMAR | Authorized Member | 10214 DOVEHILL LN, CLERMONT, FL 34711 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REGISTERED AGENT NAME CHANGED | 2023-01-16 | OMAR, GUARDADO | - |
REGISTERED AGENT ADDRESS CHANGED | 2023-01-16 | 10214 DOVEHILL LN, CLERMONT, FL 34711 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-01-23 |
ANNUAL REPORT | 2023-01-16 |
Florida Limited Liability | 2021-12-13 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347487639 | 0419730 | 2024-05-16 | 9548 BEAUTIFUL WAY, WINTER GARDEN, FL, 34787 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1748755 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19260102 A02 |
Issuance Date | 2024-06-06 |
Current Penalty | 1382.5 |
Initial Penalty | 2765.0 |
Final Order | 2024-06-20 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(2): The employer did not ensure that each affected employee uses eye protection that provides side protection when there is a hazard from flying objects. Detachable side protectors (e.g. clip-on or slide-on side shields) meeting the pertinent requirements of this section are acceptable. a. On or about May 16, 2024, at a residential construction site: employees were exposed to eye injury hazards while using pneumatic nail guns to install shingles on a 5/12 pitched roof, in that eye and face protection was not used. |
Citation ID | 01002 |
Citaton Type | Other |
Standard Cited | 19260501 B13 |
Issuance Date | 2024-06-06 |
Current Penalty | 2419.5 |
Initial Penalty | 4839.0 |
Final Order | 2024-06-20 |
Nr Instances | 1 |
Nr Exposed | 7 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). a. On or about May 16, 2024, at a residential construction site: employees were exposed to 21-foot fall hazards while replacing shingles on a 5/12 pitched roof, in that fall protection was not used. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2024-06-06 |
Current Penalty | 1728.5 |
Initial Penalty | 3457.0 |
Final Order | 2024-06-20 |
Nr Instances | 1 |
Nr Exposed | 7 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1):The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards. a. On or about May 16, 2024, at a residential construction site: employees were exposed to 21-foot fall hazards while replacing shingles on a 5/12 pitched roof, in that fall protection training was not provided. |
Citation ID | 01004 |
Citaton Type | Other |
Standard Cited | 19261053 B01 |
Issuance Date | 2024-06-06 |
Current Penalty | 1728.5 |
Initial Penalty | 3457.0 |
Final Order | 2024-06-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. a) On or about May 16, 2024, at a residential construction site: employees were exposed to 12-foot fall hazards in that side rail of the ladder was extended to approximately 18 inches over the landing to access the 5/12 pitched roof. |
Date of last update: 12 Feb 2025
Sources: Florida Department of State