Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-06-21
|
Emphasis |
L: FALL, N: FALL
|
Case Closed |
2024-07-24
|
Related Activity
Type |
Referral |
Activity Nr |
2087027 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260020 B01 |
Issuance Date |
2023-10-05 |
Abatement Due Date |
2023-11-01 |
Current Penalty |
3125.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-11-16 |
Nr Instances |
2 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.20(b)(1):The employer did not initiate and maintain such programs as may be necessary to comply with this part. a.) At the jobsite Alexan Grove TCR Project, located at 6401 Emmy Ln, Wesley Chapel, FL 33544, building number 6558, On or about June 21, 2023; the employer exposed employees to fall hazards of 11 feet, in that, employees were installing roof sheathing, during which time the employer failed to initiate and maintain safety and health programs as necessary to comply with fall protection. b.) At the jobsite Alexan Grove TCR Project, located at 6401 Emmy Ln, Wesley Chapel, FL 33544, building number 6794, On or about June 21, 2023; the employer exposed employees to fall hazards of 11 feet, in that, employees were installing roof trusses, during which time the employer failed to initiate and maintain safety and health programs as necessary to comply with fall protection. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260020 B02 |
Issuance Date |
2023-10-05 |
Abatement Due Date |
2023-11-01 |
Current Penalty |
3125.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-11-16 |
Nr Instances |
2 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.20(b)(2):The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s) a. At the jobsite Alexan Grove TCR Project, located at 6401 Emmy Ln, Wesley Chapel, FL 33544, building number 6558, On or about June 21, 2023; the employer exposed employees to fall hazards of eleven feet, in that, employees were installing roof sheathing, during which time the employer failed to initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s). b. At the jobsite Alexan Grove TCR Project, located at 6401 Emmy Ln, Wesley Chapel, FL 33544, building number 6794, On or about June 21, 2023; the employer exposed employees to fall hazards of eleven feet, in that, employees were installing roof trusses, during which time the employer failed to initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s). |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2023-10-05 |
Abatement Due Date |
2023-11-01 |
Current Penalty |
3125.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-11-16 |
Nr Instances |
2 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. At the jobsite Alexan Grove TCR Project, located at 6401 Emmy Ln, Wesley Chapel, FL 33544, building number 6558, On or about June 21, 2023; the employer exposed employees to fall hazards of 11 feet, in that, employees were installing roof sheathing without being protected by a fall protection system. b. At the jobsite Alexan Grove TCR Project, located at 6401 Emmy Ln, Wesley Chapel, FL 33544, building number 6794, On or about June 21, 2023; the employer exposed employees to fall hazards of 11 feet, in that, employees were installing roof sheathing without being protected by a fall protection system. |
|
|