Search icon

M&R HOME FRAMING LLC - Florida Company Profile

Company Details

Entity Name: M&R HOME FRAMING LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

M&R HOME FRAMING LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 02 Dec 2021 (3 years ago)
Date of dissolution: 14 Jan 2025 (3 months ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 14 Jan 2025 (3 months ago)
Document Number: L21000511183
FEI/EIN Number 87-4615578

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 5291 COLLINS RD LOT 235, JACKSONVILLE, FL, 32244, US
Mail Address: 5291 COLLINS RD LOT 235, JACKSONVILLE, FL, 32244, US
ZIP code: 32244
County: Duval
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MESQUITE BUSINESS SOLUTION INC Agent -
HERNANDEZ MARTINEZ DANIEL Manager 5291 COLLINS RD LOT 235, JACKSONVILLE, FL, 32244

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2025-01-14 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2024-09-27 - -

Documents

Name Date
VOLUNTARY DISSOLUTION 2025-01-14
ANNUAL REPORT 2023-01-04
ANNUAL REPORT 2022-01-26
Florida Limited Liability 2021-12-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347222408 0419700 2024-01-22 60-66 WOODLAND PARK DRIVE, PONTE VEDRA BEACH, FL, 32081
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2024-01-22
Emphasis N: FALL
Case Closed 2024-05-29

Related Activity

Type Referral
Activity Nr 2121987
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2024-04-15
Current Penalty 2903.4
Initial Penalty 4839.0
Final Order 2024-05-08
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a. At 66-70 Woodland Park Dr, Ponte Vedra Beach, FL, on or about January 22, 2024 and other times prior, the employer allowed employees to use a single 2 x 6-inches wide scaffold platform over a floor opening as a walking-working platform to build interior walls, exposing employees to a 10 feet-9 inches feet fall hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B04 I
Issuance Date 2024-04-15
Current Penalty 2903.4
Initial Penalty 4839.0
Final Order 2024-05-08
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. a. At 66-70 Woodland Park Dr, Ponte Vedra Beach, FL, on or about January 20, 2024, employees doing interior wall framing work on the 2nd floor were not protected from falling through the staircase opening by the use of personal fall arrest systems, covers, or guardrail systems erected around the opening, exposing to a 10 feet-9 inches fall hazard.
347077224 0419700 2023-11-02 ALLURE LANE - BUILDING 10 AND 15, JACKSONVILLE, FL, 32246
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2023-11-02
Emphasis N: FALL, P: FALL
Case Closed 2024-05-29

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2024-04-22
Current Penalty 1659.0
Initial Penalty 2765.0
Final Order 2024-05-08
Nr Instances 2
Nr Exposed 12
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee was using eye or face protection when exposed to eye or face hazards from flying particles. a. At a temporary residential worksite, located at 4561 Allure Lane - Building 15, Jacksonville, FL 32246: On or about November 2, 2023, the employer exposed employees to eye injury hazards caused by airborne debris and flying objects, in that eye protection were not utilized by the employees, while using nail guns to install sheathing and a saw to cut sheets of plywood. b. At a temporary residential worksite, located at Allure Lane - Building 10, Jacksonville, FL 32246: On or about November 2, 2023, the employer exposed an employee to eye injury hazards caused by airborne debris and flying objects, in that eye protection was not utilized by the employee while he was using a nail gun to install roofing shingles.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-04-22
Current Penalty 3871.2
Initial Penalty 6452.0
Final Order 2024-05-08
Nr Instances 2
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: a. At Building 10, On a residential worksite, located at 4561 Allure Lane, Jacksonville, FL 32246: On or about November 2, 2023, the employer exposed employees to fall hazards, in that, fall protection were not utilized by the employees walking the sil plates and working near edge of buildings. The employees were being exposed to fall hazards up to 18 feet 7-inches. b. At Building 15, On a residential worksite, located at Allure Lane, Jacksonville, FL 32246: On or about November 2, 2023, the employer exposed an employee to fall hazards, in that, fall protection was not utilized by the employees installing roof shingles. The employee was being exposed to fall hazards up to 30 feet 4-inches.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-04-22
Current Penalty 1659.0
Initial Penalty 2765.0
Final Order 2024-05-08
Nr Instances 1
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access. a. Front of Building 15, On a temporary residential job site located at 4561 Allure Lane -- Building 15, Jacksonville, FL 32246: On or about November 2, 2023, the employer exposed employees to fall hazards ranging from 10-foot, in that the ladders side rails were not extended 3 feet above the landing and were not tied off.

Date of last update: 01 Apr 2025