Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2016-12-15
|
Emphasis |
L: LEAD, N: AMPUTATE, N: LEAD
|
Case Closed |
2018-04-16
|
Related Activity
Type |
Complaint |
Activity Nr |
1163092 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A02 |
Issuance Date |
2017-05-05 |
Abatement Due Date |
2017-06-01 |
Current Penalty |
5070.0 |
Initial Penalty |
5070.0 |
Final Order |
2017-06-07 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: a) In the manufacturing area, employees were exposed to amputation hazards, in that, the Easy Load Solder Change Over Machine hood for the RPS Rhythm Slide Selective Soldering System was not affixed to the machine. This violation was observed on or about December 15, 2016. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100305 D02 |
Issuance Date |
2017-05-05 |
Current Penalty |
3622.0 |
Initial Penalty |
3622.0 |
Final Order |
2017-06-07 |
Nr Instances |
1 |
Nr Exposed |
21 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets, cutout boxes, or enclosures designed for the purpose and/or were not dead front: a) In the manufacturing area by the bathrooms, employees were exposed to electrical hazards from the dead front and trim of the breaker box that was removed. This violation was observed on or about December 15, 2016. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19101025 D02 |
Issuance Date |
2017-05-05 |
Abatement Due Date |
2017-06-01 |
Current Penalty |
3622.0 |
Initial Penalty |
3622.0 |
Final Order |
2017-06-07 |
Nr Instances |
1 |
Nr Exposed |
21 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1025(d)(2): An initial determination was not made to determine if any employee may be exposed to lead at or above the action level: a) In the manufacturing area, the employer did not do an initial determination to determine if any employee may be exposed to lead. This violation was discovered on or about December 15, 2016. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19101025 H01 |
Issuance Date |
2017-05-05 |
Abatement Due Date |
2017-06-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-06-07 |
Nr Instances |
8 |
Nr Exposed |
21 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead: a) On the MPM Momentum handle, 390.2um (micrograms) of lead was found. This violation was discovered on or about December 15, 2016. b) On the Board Load Hood handle of the RPS Rhythm Slide Selective Soldering System, 170.00um (micrograms) of lead was found. This violation was discovered on or about December 15, 2016. c) On the Right desk/table by the RPS Rhythm Slide Selective Soldering System, 130.00um (micrograms) of lead was found. This violation was discovered on or about December 15, 2016. d) On the mouse connected to the RPS Rhythm Slide Selective Soldering System, 97.05um (micrograms) of lead was found. This violation was discovered on or about December 15, 2016. e) On the Table surface by the SMT machine, 60.9um (micrograms) of lead was found. This violation was discovered on or about December 15, 2016. f) On the Left desk/table by the RPS Rhythm Slide Selective Soldering System, 36.355um (micrograms) of lead was found. This violation was discovered on or about December 15, 2016. g) On the start button connected to the RPS Rhythm Slide Selective Soldering System, 19.095um (micrograms) of lead was found. This violation was discovered on or about December 15, 2016. h) On the table in the eating area, 4.1645um (micrograms) of lead was found. This violation was discovered on or about December 15, 2016. i) On the Refrigerator handle, 1.255um (micrograms) of lead was found. This violation was discovered on or about December 15, 2016. |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19101025 M01 I |
Issuance Date |
2017-05-05 |
Abatement Due Date |
2017-06-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-06-07 |
Nr Instances |
1 |
Nr Exposed |
21 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1025(m)(1)(i): The employer did not comply with all the requirements of the Hazard Communication Standard for lead: a) In the workplace, the employer did not have a Hazard Communication Program. This violation was discovered on or about December 15, 2016. |
|
Citation ID |
01003D |
Citaton Type |
Serious |
Standard Cited |
19101025 L01 II |
Issuance Date |
2017-05-05 |
Abatement Due Date |
2017-06-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-06-07 |
Nr Instances |
1 |
Nr Exposed |
21 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1025(l)(1)(ii): The employer did not train each employee who is subject to exposure to lead at or above the action level, or for whom the possibility of skin or eye irritation exists, in accordance with the requirements of 29 CFR 1910.1025: a) In the workplace, employees were not provided with training regarding the lead in their work area. This violation was discovered on or about December 15, 2016. |
|
|