Search icon

REDTAIL ROOFING LLC - Florida Company Profile

Company Details

Entity Name: REDTAIL ROOFING LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

REDTAIL ROOFING LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 20 Apr 2021 (4 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 29 Oct 2024 (6 months ago)
Document Number: L21000171974
FEI/EIN Number 86-3590302

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3167 Saint Johns Bluff Rd S, JACKSONVILLE, FL, 32246, US
Mail Address: 3167 Saint Johns Bluff Rd S, JACKSONVILLE, FL, 32246, US
ZIP code: 32246
County: Duval
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
BLACK TAYLOR Manager 3167 Saint Johns Bluff Rd S, JACKSONVILLE, FL, 32246
BLACK TAYLOR Agent 1437 MARKET ST, TALLAHASSEE, FL, 32312

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2024-10-29 3167 Saint Johns Bluff Rd S, Suite 103, JACKSONVILLE, FL 32246 -
CHANGE OF MAILING ADDRESS 2024-10-29 3167 Saint Johns Bluff Rd S, Suite 103, JACKSONVILLE, FL 32246 -
REINSTATEMENT 2024-10-29 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2024-09-27 - -
LC AMENDMENT 2023-12-18 - -
REGISTERED AGENT NAME CHANGED 2023-10-11 BLACK, TAYLOR -
REINSTATEMENT 2023-10-11 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2023-09-22 - -
LC AMENDMENT 2023-02-10 - -

Documents

Name Date
ANNUAL REPORT 2025-02-10
REINSTATEMENT 2024-10-29
LC Amendment 2023-12-18
REINSTATEMENT 2023-10-11
LC Amendment 2023-02-10
Florida Limited Liability 2021-04-20

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347244196 0419700 2024-01-29 3060 THORN GLEN COURT, JACKSONVILLE, FL, 32256
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2024-01-29
Emphasis N: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260102 A01
Issuance Date 2024-07-18
Current Penalty 26615.0
Initial Penalty 26615.0
Final Order 2024-08-13
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: a. On the roof of a single-family residence, at a temporary residential worksite, located at 3060 Thorn Glen Court in Jacksonville, Florida 32208: On or about January 24, 2024, the employer exposed an employee to eye injury hazards caused by airborne debris and flying objects, in that eye protection was not utilized by the employee, while using a pneumatic nail gun to install roofing shingles. Redtail Roofing, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.102(a)(1), which was contained in OSHA Inspection Number 1653232, Citation Number 1, Item Number 2, and was affirmed as a final order on May 25, 2023, with respect to a workplace located at 9513 Arbor Oak Lane, Lot 11, Jacksonville, FL 32208. Redtail Roofing, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.102(a)(1), which was contained in OSHA Inspection Number 1639449, Citation Number 1, Item Number 1, and was affirmed as a final order on March 15, 2023, with respect to a workplace located at 3117 Sedona Trail, Jacksonville, FL 32208.
Citation ID 01002
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2024-07-18
Current Penalty 53238.0
Initial Penalty 53238.0
Final Order 2024-08-13
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On the roof of a single-family residence, at a temporary residential worksite, located at 3060 Thorn Glen Court in Jacksonville, Florida 32208: On or about January 29, 2024, the employer exposed employees to 9-foot fall hazards, in that fall protection was not utilized by employees while installing roof shingles. Redtail Roofing, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13) which was contained in OSHA Inspection Number 1657238, Citation Number 1, Item Number 1, and was affirmed as a final order on May 25, 2023, with respect to a workplace located at 350 West 65th Street, Jacksonville, FL 32208. Redtail Roofing, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.102(a)(1), which was contained in OSHA Inspection Number 1653232, Citation Number 1, Item Number 2, and was affirmed as a final order on May 25, 2023, with respect to a workplace located at 9513 Arbor Oak Lane, Lot 11, Jacksonville, FL 32208. Redtail Roofing, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.102(a)(1), which was contained in OSHA Inspection Number 1639449, Citation Number 1, Item Number 1, and was affirmed as a final order on March 15, 2023, with respect to a workplace located at 3117 Sedona Trail, Jacksonville, FL 32208.
346572381 0419700 2023-03-14 350 WEST 65TH STREET, JACKSONVILLE, FL, 32208
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2023-03-14
Emphasis L: FALL, P: FALL
Case Closed 2023-11-03

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2023-04-13
Current Penalty 2406.25
Initial Penalty 6875.0
Final Order 2023-05-25
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On a 4:12 pitched roof of a temporary residential worksite, at 350 W 65th Street, Jacksonville, Florida 32208: On or about March 14, 2023, the employer exposed employees to fall hazards ranging from 8 to 15 feet 6-inches, in that fall protection was not utilized by employees while performing roofing activities.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2023-04-13
Current Penalty 1804.6
Initial Penalty 5156.0
Final Order 2023-05-25
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1):Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access: a. Left side of home near door, located at 350 W 65th Street, Jacksonville, FL 32208: On or about March 14, 2023, the employer exposed employees to fall hazards, in that, the 16-foot extension ladder was only raised one rung above the landing.
346532328 0419700 2023-02-27 9513 ARBOR OAK LANE LOT 11, JACKSONVILLE, FL, 32208
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2023-02-27
Emphasis P: FALL, L: FALL
Case Closed 2023-11-03

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2023-03-21
Current Penalty 1640.45
Initial Penalty 4687.0
Final Order 2023-05-25
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a):Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, was not protected by protective helmets: a. On the roof of a temporary residential worksite, at 9513 Arbor Oak Lane, Lot 11, Jacksonville, Florida 32208: On or about February 27, 2023, the employer exposed three employees to head injuries hazards caused by flying objects, in that hard hats were not utilized by the employees, while working underneath other employees picking up debris.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2023-03-21
Current Penalty 1640.45
Initial Penalty 4687.0
Final Order 2023-05-25
Nr Instances 2
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: a. On the roof of a temporary residential worksite, at 9513 Arbor Oak Lane, Jacksonville, Florida 32208: On or about February 27, 2023, the employer exposed five employees to eye injury hazards caused by airborne debris and flying objects, in that eye protection were not utilized by the employees, while using pneumatic nail guns to install roofing shingles. b. On the roof of a temporary residential worksite, at 9513 Arbor Oak Lane, Jacksonville, Florida 32208: On or about February 27, 2023, the employer exposed one employee to eye injury hazards caused by airborne debris and flying objects, in that eye protection was not utilized by the employee using the DeWalt saw to cut plywood.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2023-03-21
Current Penalty 2734.55
Initial Penalty 7813.0
Final Order 2023-05-25
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On a 6:12 pitched roof of a temporary residential worksite, at 9513 Arbor Oak Lane, in Jacksonville, Florida 32208: On or about February 27, 2023, the employer exposed five employees to fall hazards ranging from 9 to 18 feet, in that fall protection was not utilized by employees while installing roof shingles.
Citation ID 02001
Citaton Type Other
Standard Cited 19040041 A01
Issuance Date 2023-03-21
Abatement Due Date 2023-03-31
Current Penalty 546.7
Initial Penalty 1562.0
Final Order 2023-05-25
Nr Instances 1
Nr Exposed 53
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.41(a)(1): the employer had not electronically submit information from their recordkeeping forms required under this part once a year and no later than the date listed in paragraph (c) of this section, March 2, 2023: a. Redtail Roofing, LLC, located at 7643 Gate Parkway, Suite 104-177, Jacksonville, Florida 32256: On or about March 10, 2023, and times prior thereto, the employer failed for calendar year 2022, to electronically submit information from the OSHA Form 300A or equivalent by March 3, 2023. The establishment employed 53 employees and was classified in the North American Industrial Classification System as 238160 during calendar year 2022.
346394497 0419700 2022-12-12 3117 SEDONA TRAIL, JACKSONVILLE, FL, 32208
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2022-12-12
Emphasis L: FALL, P: FALL
Case Closed 2023-06-01

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2023-02-14
Current Penalty 2679.0
Initial Penalty 4465.0
Final Order 2023-03-15
Nr Instances 1
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: a. On the roof of a temporary residential worksite, at 3117 Sedona Trail, Jacksonville, Florida 32208: On or about December 12, 2022, the employer exposed eight employees to eye injury hazards caused by airborne debris and flying objects, in that eye protection were not utilized by the employees, while using pneumatic nail guns to install roofing shingles.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2023-02-14
Current Penalty 3750.0
Initial Penalty 6250.0
Final Order 2023-03-15
Nr Instances 1
Nr Exposed 8
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On a 6:12 pitched roof of a temporary residential worksite, at 3117 Sedona Trail, in Jacksonville, Florida 32208: On or about December 12, 2022, the employer exposed eight employees to fall hazards ranging from 9 to 18 feet, in that fall protection was not utilized by employees while installing roof shingles.

Date of last update: 02 Apr 2025