Entity Name: | OPTION 1 PAINTING LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
OPTION 1 PAINTING LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 08 Feb 2021 (4 years ago) |
Document Number: | L21000065259 |
FEI/EIN Number |
86-2135429
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 4456 GREENWOOD AVE, FORT MYERS, FL, 33905, US |
Mail Address: | 4456 GREENWOOD AVE, FORT MYERS, FL, 33905, US |
ZIP code: | 33905 |
County: | Lee |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
TERRAZA BRITO RICARDA M | Authorized Member | 4456 GREENWOOD AVE, FORT MYERS, FL, 33905 |
TERRAZA BRITO RICARDA M | Agent | 4456 GREENWOOD AVE, FORT MYERS, FL, 33905 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REGISTERED AGENT NAME CHANGED | 2023-04-10 | TERRAZA BRITO, RICARDA M | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-03-26 |
ANNUAL REPORT | 2023-04-10 |
ANNUAL REPORT | 2022-03-10 |
Florida Limited Liability | 2021-02-08 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347355927 | 0420600 | 2024-03-19 | 3929 WOODLAKE DRIVE, BONITA SPRINGS, FL, 33931 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Accident |
Activity Nr | 2144802 |
Type | Referral |
Activity Nr | 2142714 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2024-09-13 |
Abatement Due Date | 2024-09-25 |
Current Penalty | 16131.0 |
Initial Penalty | 16131.0 |
Final Order | 2024-10-11 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Accident |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: (a) 3929 Woodlake Drive Bonita Springs, Florida - On or about March 19, 2024, the employer exposed employees to a 24 foot fall while standing on a second story roof overhang, spraying paint to a roof gable without fall protection. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2024-09-13 |
Abatement Due Date | 2024-10-02 |
Current Penalty | 4839.0 |
Initial Penalty | 4839.0 |
Final Order | 2024-10-11 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1):The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) 3929 Woodlake Drive Bonita Springs, Florida - On or about March 19, 2024, the employer exposed employees to fall hazards in that, employees were not provided with a training program in the recognition of hazards associated with falls or procedures necessary to eliminate of minimize those hazards while conducting painting activities on a residential roof approximately 24 feet from the ground without the use of fall protection. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B04 |
Issuance Date | 2024-09-13 |
Current Penalty | 4839.0 |
Initial Penalty | 4839.0 |
Final Order | 2024-10-11 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(4):Ladder(s) were used for purposes other than the purpose for which they were designed: (a) 3929 Woodlake Drive Bonita Springs, Florida - On or about March 19, 2024, the employer exposed employees to falls in that, a Werner step-ladder was not used in accordance with the manufacturers instructions as it was propped in the closed position, against the outside wall on the first floor roof for employees to use for access to second story roof work area. |
Date of last update: 03 Apr 2025
Sources: Florida Department of State