Search icon

SDC SIDING 0913 LLC - Florida Company Profile

Company Details

Entity Name: SDC SIDING 0913 LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

SDC SIDING 0913 LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 29 Jan 2021 (4 years ago)
Document Number: L21000054049
FEI/EIN Number 86-2088930

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 10525 Ladybug Cove, Parrish, FL, 34219, US
Mail Address: 10525 Ladybug Cove, Parrish, FL, 34219, US
ZIP code: 34219
County: Manatee
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
LOZANO SANTIAGO G President 10525 Ladybug Cove, Parrish, FL, 34219
LOZANO SANTIAGO Agent 10525 Ladybug Cove, Parrish, FL, 34219

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2024-02-17 10525 Ladybug Cove, Parrish, FL 34219 -
CHANGE OF MAILING ADDRESS 2024-02-17 10525 Ladybug Cove, Parrish, FL 34219 -
REGISTERED AGENT ADDRESS CHANGED 2024-02-17 10525 Ladybug Cove, Parrish, FL 34219 -

Documents

Name Date
ANNUAL REPORT 2024-02-17
ANNUAL REPORT 2023-04-14
ANNUAL REPORT 2022-04-13
Florida Limited Liability 2021-01-29

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347296113 0420600 2024-02-16 6002 HIDDEN BRANCH, APOLLO BEACH, FL, 33572
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-02-16
Emphasis N: FALL, P: FALL
Case Closed 2024-03-19
347075848 0420600 2023-11-01 RIO LIMPION LN,, NOKOMIS, FL, 34274
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2023-11-01
Emphasis N: FALL, P: FALL

Related Activity

Type Inspection
Activity Nr 1707578
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260502 D06 II
Issuance Date 2023-12-22
Abatement Due Date 2024-01-22
Current Penalty 3349.0
Initial Penalty 3349.0
Final Order 2024-01-30
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(6)(ii): A snaphook not of the locking type and not designed to be connected to one another were engaged to each other. a) At the work site located at Rio Limpion Ln, Nokomis, Florida: On or about November 1, 2023, employees were exposed to a fall hazard of 51-ft to the lower level, in that, the fall protection system provided was not installed as intended by the manufacturer as the self retracting life-line used was attached to a free-fall lanyard and not to the anchor, while engaged in siding work on a 8:12 roof.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260502 D15
Issuance Date 2023-12-22
Abatement Due Date 2024-01-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-01-30
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(15): Anchorage points used for attachment of personal fall arrest equipment were not independent of any anchorage point being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee: a) At the work site located at Rio Limpion Ln, Nokomis, Florida: On or about November 1, 2023, employees were exposed to a fall hazard, in that, employees engaged in roofing activities were using temporary anchor points that were not properly installed according to the manufacturers installation instructions.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2023-12-22
Abatement Due Date 2024-01-22
Current Penalty 3349.0
Initial Penalty 3349.0
Final Order 2024-01-30
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1):The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards. a) At the work site located at Rio Limpion Ln, Nokomis, Florida: On or about November 1, 2023, employees working on the roof installing siding were not trained on how to recognize and minimize fall hazards.

Date of last update: 03 Apr 2025