Search icon

STGO PRO4MANCE, LLC

Company Details

Entity Name: STGO PRO4MANCE, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Company
Status: Active
Date Filed: 05 Oct 2020 (4 years ago)
Document Number: L20000314548
FEI/EIN Number 85-3149574
Address: 3500 Posner Blvd Ste: 1362, Davenport, FL 33837
Mail Address: PO Box 317, Davenport, FL 33836
ZIP code: 33837
County: Polk
Place of Formation: FLORIDA

Agent

Name Role
ANDERSON REGISTERED AGENTS, INC. Agent

Manager

Name Role Address
Santiago, Emmanuel Manager 3500 Posner Blvd Ste: 1362, Davenport, FL 33837
Santiago, Angel G. Manager 3500 Posner Blvd Ste: 1362, Davenport, FL 33837

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2024-04-13 3500 Posner Blvd Ste: 1362, Davenport, FL 33837 No data
CHANGE OF MAILING ADDRESS 2024-04-13 3500 Posner Blvd Ste: 1362, Davenport, FL 33837 No data
REGISTERED AGENT NAME CHANGED 2024-04-13 ANDERSON REGISTERED AGENTS, INC. No data
REGISTERED AGENT ADDRESS CHANGED 2024-04-13 625 E. Twiggs Street, Suite 110, Tampa, FL 33602 No data

Documents

Name Date
ANNUAL REPORT 2024-04-13
ANNUAL REPORT 2023-04-25
ANNUAL REPORT 2022-03-30
ANNUAL REPORT 2021-04-22
Florida Limited Liability 2020-10-05

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345680219 0419730 2021-12-09 14344 ISLAND COVE DR., ORLANDO, FL, 32824
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2021-12-09
Emphasis L: FALL
Case Closed 2022-12-16

Related Activity

Type Inspection
Activity Nr 1568604
Safety Yes
Type Inspection
Activity Nr 1568596
Safety Yes
Type Inspection
Activity Nr 1568601
Safety Yes
Type Complaint
Activity Nr 1840085
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2022-04-27
Current Penalty 2219.01
Initial Penalty 4351.0
Final Order 2022-06-14
Nr Instances 3
Nr Exposed 18
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On the roof of residential condos located at Building #30, of 1208 Garden Isle Ct, 1209 Garden Isle Ct. and 11427 Bay Isle Dr. Orlando FL, employees were exposed to a fall hazard of approximately 9 feet height and higher while engaged in roofing activities on a steep roof (5:12), in that the employees were not using any means of fall protection, on or about 12/09/2021. The controlling employer failed to ensure workers were protected from fall hazards. b. On the roof of residential condos located at Building #34 of 1208 Garden Isle Ct, 1209 Garden Isle Ct. and 11427 Bay Isle Dr. Orlando FL, employees were exposed to a fall hazard of approximately 9 feet height and higher while engaged in roofing activities on a steep roof (5:12), in that the employees were not using any means of fall protection, on or about 12/09/2021. The controlling employer failed to ensure workers were protected from fall hazards. c. On the roof of residential condos located at Building #40 of 1208 Garden Isle Ct, 1209 Garden Isle Ct. and 11427 Bay Isle Dr. Orlando FL, employees were exposed to a fall hazard of approximately 9 feet height and higher while engaged in roofing activities on a steep roof (5:12), in that the employees were not using any means of fall protection, on or about 12/09/2021. The controlling employer failed to ensure workers were protected from fall hazards.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2022-04-27
Current Penalty 2219.01
Initial Penalty 4351.0
Final Order 2022-06-14
Nr Instances 1
Nr Exposed 18
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1):Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access. a. On the roof of residential condos located at 1208 Garden Isle Ct, 1209 Garden Isle Ct. and 11427 Bay Isle Dr. Orlando FL, employees were exposed to a fall hazard of when accessing a 9 foot roof with portable ladder side rails not properly extended, on or about 12/09/2021. The controlling employer failed to ensure workers were protected from fall hazards by not enforcing the appropriate ladder placement.

Date of last update: 14 Feb 2025

Sources: Florida Department of State