Search icon

N.J.A.M ROOFING & CONSTRUCTION, LLC - Florida Company Profile

Company Details

Entity Name: N.J.A.M ROOFING & CONSTRUCTION, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

N.J.A.M ROOFING & CONSTRUCTION, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 05 Aug 2020 (5 years ago)
Date of dissolution: 27 Sep 2024 (7 months ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2024 (7 months ago)
Document Number: L20000235125
FEI/EIN Number 36-4974635

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3003 45TH ST SW, LEHIGH ACRES, FL, 33976, US
Mail Address: 3003 45TH ST SW, LEHIGH ACRES, FL, 33976, US
ZIP code: 33976
County: Lee
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ACOSTA MURILLO NEHEMIAS J Manager 3003 45TH ST SW, LEHIGH ACRES, FL, 33976
ACOSTA MURILLO NEHEMIAS J Agent 3003 45TH ST SW, LEHIGH ACRES, FL, 33976

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2024-09-27 - -
CHANGE OF PRINCIPAL ADDRESS 2023-06-27 3003 45TH ST SW, LEHIGH ACRES, FL 33976 -
CHANGE OF MAILING ADDRESS 2023-06-27 3003 45TH ST SW, LEHIGH ACRES, FL 33976 -
REGISTERED AGENT ADDRESS CHANGED 2023-06-27 3003 45TH ST SW, LEHIGH ACRES, FL 33976 -
LC NAME CHANGE 2021-01-29 N.J.A.M ROOFING & CONSTRUCTION, LLC -

Documents

Name Date
ANNUAL REPORT 2023-06-27
ANNUAL REPORT 2022-04-27
ANNUAL REPORT 2021-04-27
LC Name Change 2021-01-29
Florida Limited Liability 2020-08-05

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346164908 0420600 2022-08-23 5050 BELL TOWER PARK BLVD, FORT MYERS, FL, 33912
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2022-09-01
Emphasis L: FALL
Case Closed 2024-10-16

Related Activity

Type Complaint
Activity Nr 1926992
Safety Yes
Type Inspection
Activity Nr 1616473
Safety Yes
Type Inspection
Activity Nr 1614404
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100178 L01 II
Issuance Date 2022-09-22
Abatement Due Date 2022-11-09
Current Penalty 3108.0
Initial Penalty 3108.0
Final Order 2023-02-24
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck (as referenced by the note contained in 1926.602(d)): a) On or about July 28, 2022 at the job-site located at 5121 Hyde Park Drive, Fort Myers, Florida, the employer did not ensure that the JCB rough terrain (Model 507.2 F, SN#: JCB5CEGVJ2735137) forklift operator had been trained prior to operation.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2022-09-22
Abatement Due Date 2022-11-09
Current Penalty 2486.0
Initial Penalty 2486.0
Final Order 2023-02-24
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59)(a) a) On or about August 11, 2022 and at times prior at the job-site located at 5110 Hyde Park Drive, Fort Myers, Florida, the employer did not develop, implement, and/or maintain at the workplace a written hazard communication program for employees handling chemical products such as, but not limited to, PG500 MB Flashing Cement, Nitrogen and Polyset Rooftile Adhesive AH-160 A & B-side
Citation ID 01002B
Citaton Type Serious
Standard Cited 19101200 G01
Issuance Date 2022-09-22
Abatement Due Date 2022-11-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-02-24
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use a) On or about August 11, 2022 and at times prior at the job-site located at 5110 Hyde Park Drive, Fort Myers, Florida, the safety data sheets were not available for employees handling chemical products such as, but not limited to, PG500 MB Flashing Cement, Nitrogen and Polyset Rooftile Adhesive AH-160 A & B-side.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2022-09-22
Abatement Due Date 2022-11-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-02-24
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59) a) On or about August 11, 2022 and at times prior at the job-site located at 5110 Hyde Park Drive, Fort Myers, Florida, employees handling chemical products such as, but not limited to, PG500 MB Flashing Cement, Nitrogen and Polyset Rooftile Adhesive AH-160 A & B-side, were not informed about the physical and health hazards of the chemicals they handle.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260451 C02 III
Issuance Date 2022-09-22
Abatement Due Date 2022-11-09
Current Penalty 3108.0
Initial Penalty 3108.0
Final Order 2023-02-24
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(iii): Unstable objects were used as working platforms: a) On or about July 28, 2022 at the job-site located at 5121 Hyde Park Drive, Fort Myers, Florida, an employee was exposed to a 28-ft fall hazard when standing on a job-made wooden work platform elevated by a JCB rough-terrain forklift (Model 507.2 F, SN#: JCB5CEGVJ2735137) while installing roof tiles to a residential structure. The wooden work platform was tied to the forks attachment by ropes, which showed signs of broken wood and lacked forklift pockets.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260451 C02 IV
Issuance Date 2022-09-22
Abatement Due Date 2022-11-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-02-24
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(iv): Front-end loaders and similar pieces of equipment were used to support scaffold platforms without being specifically designed by the manufacturer for such use: a) On or about July 28, 2022 at the job-site located at 5121 Hyde Park Drive, Fort Myers, Florida, while installing roof tiles an employee was exposed to a 28- foot fall hazard when standing on a job-made wooden work platform lifted by a JCB rough terrain (Model 507.2 F, SN#: JCB5CEGVJ2735137) with fork attachment.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2022-09-22
Abatement Due Date 2022-11-09
Current Penalty 3108.0
Initial Penalty 3108.0
Final Order 2023-02-24
Nr Instances 2
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) On or about July 28, 2022 at the job-site located at 5121 Hyde Park Drive, Fort Myers, Florida, employees were exposed to a 28- foot fall hazard while installing roof tiles on the 4 in 12 pitched (vertical to horizontal) roof, in that, fall protection was not used. b) On or about July 28, 2022 at the job-site located at 5121 Hyde Park Drive, Fort Myers, Florida, employees were exposed to an 8- foot fall hazard while spraying adhesive and blowing dust from roof tiles on the 4 in 12 pitched (vertical to horizontal) roof, in that, fall protection was not used. c) On or about July 28, 2022 at the job-site located at 5121 Hyde Park Drive, Fort Myers, Florida, employees were exposed to a 28- foot fall hazard while installing roof tiles on the 4 in 12 pitched (vertical to horizontal) roof; at the time a wooden work platform was used to access the roof, in that, fall protection was not used. d) On or about August 11, 2022 at the job-site located at 5110 Hyde Park Drive, Fort Myers, Florida, employees were exposed to a 28- foot fall hazard while installing roof tiles on the 4 in 12 pitched (vertical to horizontal) roof, in that, fall protection was not used.

Date of last update: 02 Apr 2025