Search icon

O.C. CONSTRUCTION SERVICES LLC - Florida Company Profile

Company Details

Entity Name: O.C. CONSTRUCTION SERVICES LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

O.C. CONSTRUCTION SERVICES LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 24 Jul 2020 (5 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 14 Dec 2021 (3 years ago)
Document Number: L20000219079
FEI/EIN Number 36-4969688

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2900 SUNI PINES BLVD, LOT 178, JACKSONVILLE BEACH, FL, 32250
Mail Address: 2900 SUNI PINES BLVD, LOT 178, JACKSONVILLE BEACH, FL, 32250
ZIP code: 32250
County: Duval
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
CRUZ OCTAVIO Manager 2900 SUNI PINES BLVD, JACKSONVILLE BEACH, FL, 32250
CRUZ OCTAVIO Agent 2900 SUNI PINES BLVD, JACKSONVILLE BEACH, FL, 32250

Events

Event Type Filed Date Value Description
REINSTATEMENT 2021-12-14 - -
REGISTERED AGENT NAME CHANGED 2021-12-14 CRUZ, OCTAVIO -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2021-09-24 - -

Documents

Name Date
REINSTATEMENT 2021-12-14
Florida Limited Liability 2020-07-24

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347717332 0419700 2024-08-28 MEZZANINE STREET BUILDING 24 #3990 HARDWICK FARMS, JACKSONVILLE, FL, 32217
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2024-08-28
Emphasis N: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2024-12-17
Abatement Due Date 2024-12-30
Current Penalty 2000.0
Initial Penalty 4610.0
Final Order 2025-01-03
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a. At a new residential construction site, located at Mezzanine Street Building 24 #3990 Hardwick Farms: On or about August 28, 2024, the employer exposed employees to struck-by hazards, in that protective eyewear was not utilized by employees while using an electrical saw, metal hammer and nail guns for framing work.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-12-17
Current Penalty 4000.0
Initial Penalty 6452.0
Final Order 2025-01-03
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. At a residential construction site located at Mezzanine Street Building 24 #3990 Hardwick Farms: On or about August 28, 2024, the employer was exposing 4 employees to a 10-foot fall hazard, in that the employees were not wearing fall protection when installing the roof trusses.
Citation ID 02001
Citaton Type Other
Standard Cited 19260025 A
Issuance Date 2024-12-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2025-01-03
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: a. At a new residential construction site, located at Mezzanine Street Building 24 #3990 Hardwick Farms: On or about August 28, 2024, employees were exposed to a trip and fall hazard while accessing the homemade ladder with wood panels and electrical cords on the floor.
Citation ID 02002
Citaton Type Other
Standard Cited 19261053 B01
Issuance Date 2024-12-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2025-01-03
Nr Instances 6
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. At a new residential construction site, located at Mezzanine Street Building 24 #3990 Hardwick Farms: On or about August 28, 2024, the employer exposed employees to a 10-foot fall hazard in that ladder used to access the roof did not extend at least 3 feet above the upper landing of the roof.
Citation ID 02003
Citaton Type Other
Standard Cited 19261060 A01 III
Issuance Date 2024-12-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2025-01-03
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a)(1)(iii): The employer did not ensure that each employee using ladders and/or stairways had been trained by a competent person in the proper construction, use, placement, and care in handling the ladders and/or stairways: a) At a new residential construction site, located at Mezzanine Street Building 24 #3990 Hardwick Farms: On or about August 28, 2024, employees were exposed to a fall hazard while using the handmade ladder to access the trusses.

Date of last update: 03 Mar 2025

Sources: Florida Department of State