Search icon

SUBCONTRACTOR SOLUTIONS LLC - Florida Company Profile

Company Details

Entity Name: SUBCONTRACTOR SOLUTIONS LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

SUBCONTRACTOR SOLUTIONS LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 08 Jul 2020 (5 years ago)
Date of dissolution: 08 Dec 2023 (a year ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 08 Dec 2023 (a year ago)
Document Number: L20000195130
FEI/EIN Number 85-1830182

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 244 15TH STREET SW, VERO BEACH, FL, 32962, US
Mail Address: 282 Clearlake Rd, Cocoa, FL, 32922, US
ZIP code: 32962
County: Indian River
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
VALDIVIA LOYDA B Manager 244 15TH STREET SW, VERO BEACH, FL, 32962
VALDIVIA LOYDA B Agent 244 15TH STREET SW, VERO BEACH, FL, 32962

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2023-12-08 - -
CHANGE OF MAILING ADDRESS 2022-01-16 244 15TH STREET SW, VERO BEACH, FL 32962 -

Documents

Name Date
VOLUNTARY DISSOLUTION 2023-12-08
ANNUAL REPORT 2023-01-17
ANNUAL REPORT 2022-01-16
ANNUAL REPORT 2021-02-02
Florida Limited Liability 2020-07-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346694433 0419700 2023-05-11 4830 ATLANTIC BOULEVARD, JACKSONVILLE, FL, 32207
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2023-05-11
Emphasis L: FALL, P: FALL
Case Closed 2023-12-19

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2023-06-08
Current Penalty 5625.6
Initial Penalty 9376.0
Final Order 2023-07-14
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, or personal fall arrest system: a. On the roof at a commercial residence, at a temporary worksite located at 4830 University Boulevard, in Jacksonville, FL: On or about May 11, 2023, and at times prior, the employer exposed employees to fall hazards, in that fall protection was not utilized by the employees while performing roofing work.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2023-06-08
Current Penalty 4781.4
Initial Penalty 7969.0
Final Order 2023-07-14
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder: a. On the roof, at a commercial residence, at a temporary worksite located at 4830 University Boulevard, in Jacksonville, FL: On or about May 11, 2023, the employer exposed employees to fall hazards, in that the ladder rails did not extend 3 feet above the upper landing surface of the roof at the eave.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261053 B22
Issuance Date 2023-06-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-07-14
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause them to lose balance and fall: a. On the roof, at a commercial residence, at a temporary worksite located at 4830 University Boulevard, in Jacksonville, FL: On or about May 11, 2023, the employer exposed employees to fall hazards, the employer exposed employees to fall hazards, in that employees were carrying tools while using extended ladder to egress to roof.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260102 A01
Issuance Date 2023-06-08
Current Penalty 11251.2
Initial Penalty 18752.0
Final Order 2023-07-14
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: a. On the roof at a commercial residence, at a temporary worksite located at 4830 University Boulevard, in Jacksonville, FL: On or about May 11, 2023, and at times prior, the employer exposed employees to eye injuries, in that eye protection was not utilized by employees who were operating pneumatic nail guns. Subcontractor Solutions, LLC, was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1926.102(a)(1), which was contained in OSHA inspection number 1551104, citation number 1, item number 1, and was affirmed as final order on December 28, 2021, with respect to workplace located at 1657 N. River Bluff Road, Jacksonville, FL.
345511042 0419700 2021-09-02 1657 N. RIVER BLUFF ROAD, JACKSONVILLE, FL, 32211
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2021-09-30
Case Closed 2022-06-08

Related Activity

Type Referral
Activity Nr 1805222
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2021-10-04
Current Penalty 4096.2
Initial Penalty 6827.0
Final Order 2021-12-28
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1):The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a. On the roof at a residence, located at 1657 N. River Bluff Road, Jacksonville, FL: On or about 8/30/2021, the employer exposed an employee to eye hazards from flying projectile nails from a pneumatic nailer and other flying debris, in that eye protection was not used when within the work area of the pneumatic nailer operator.

Date of last update: 01 Mar 2025

Sources: Florida Department of State